• 제목/요약/키워드: Effective Width

검색결과 1,191건 처리시간 0.027초

의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구 (A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities)

  • 최윤주;김윤성;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

Oxidative Line Width Reduction of Imprinted Nanopatterns

  • Park, Dae Keun;Kang, Aeyeon;Jeong, Mira;Lee, Jaejong;Yun, Wan Soo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.650-650
    • /
    • 2013
  • Although imprinted nanopatterns of organic polymer can be modified by the heat treatment [1], it generally requires high process temperatures and is material-dependent since the heat-induced mass loss of the organic polymer is greatly affected by its chemical characteristics. When oxygen is added during the annealing process, one can reduce the process temperature as well as the dependence of the materials. With the oxygen, line width reduction of a polymer (SU-8) patterns could be accomplished at temperature of as low as $250^{\circ}C$ which was not possible in the heat only process. This oxidative line width reduction can be dramatically promoted with the introduction of oxygen plasma. The oxygen plasma, with its highly-reactive oxygen species, vigorously etches away the organic materials, proven to be extremely effective line with reduction method. It is, however, very hard to control the extent and homogeneity of the etching, particularly of very fine patterns. Here, we report an effective and reliable line width reduction method of imprinted nanopatterns by combined plasma and heat treatment. The merits of this process include the reduction of process temperature, time and material-dependence.

  • PDF

골지천 유역의 최적관리기법 적용에 따른 수질개선효과 분석 (Application and Effectiveness Analysis of SWAT Filter Strip in Golji Watershed)

  • 박윤식;권재혁
    • 한국환경농학회지
    • /
    • 제33권1호
    • /
    • pp.30-36
    • /
    • 2014
  • BACKGROUND: Best management practices are often implemented to control nonpoint source pollutants. Best management practices need to be simulated and analyzed for effective Best management practices implementations. Filter strip is one of effective Best management practices in agricultural areas. METHODS AND RESULTS: Soil and Water Assessment Tool model was selected to explore the effectiveness of filter strip to control total phosphorous in Golji watershed. Soil and Water Assessment Tool model was calibrated for flow and total phosphorous by Sequential Uncertainty Fittin ver.2 algorithm provided in Soil and Water Assessment Tool-Calibration and Uncertainty Procedures. Three scenarios defined by filter strip width were applied. The filter strip width of 5 m was able to reduce the most amount of total phosphorous. In other words, the total phosphorous reduction by filter strip of 5 m was 28.0%, while the reduction was 17.5% by filter strip of 1 m. However, the reduction per unit filter strip width were 17.4%, 8.0%, and 4.5% for 1 m, 3 m, and 5 m of filter strips, respectively. CONCLUSION: Best management practices need to be simulated and analyzed so that the BMP scenario can be cost-effective. A large size of BMP might be able to control large amount of pollutants, however it would not be indicated as a cost-effective strategy.

회전익 항공기 공중살포 특성 측정 (Measuring the characteristic of aerial spray by rotary wing)

  • 임세훈;송병흠
    • 한국항공운항학회지
    • /
    • 제17권1호
    • /
    • pp.46-51
    • /
    • 2009
  • This paper presents results from field studies carried out to monitor off-target droplet movement of endosulfan insecticide applied to the Korea chestnut tree area. As a results, mean airborne drift values were recorded 25m as average from downwind of a single flight line(sample line) in mountain terrain and mean effective swath width was recorded 19.5m as average in a plain. In terms of characteristics of geography of Korea aerial application is mainly carried out in mountain terrain. The equipment, weather conditions, and appropriate aerial spray technic are required for effective aerial application. In particular, the pilot can get effective results when he only sprays with consideration of environment factors since there is much turbulence in mountain terrain. Eventually, the most effective factor of droplets drift is to estimate the local weather conditions exactly.

  • PDF

형상비가 다른 T형벽체의 유효폭 산정을 위한 비선형 FEM 해석 (A Study on Nonlinear FEM Analysis for the Effective Widths of T-shaped Structural Walls with Different Aspect Ratios)

  • 조남선;하상수;오영훈;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.67-74
    • /
    • 2001
  • In domestic, irregular walls such as T, L, H and Box shapes are considered as rectangular wall in the design of bearing wall apartment building. The strengths of walls, therefore, can be underestimated in case of using the current design process. Irregular walls are connected to each other as rigid joint so that part of the load can be resisted by the wall perpendicular to the load direction. This resistance can be caused by the effective width of perpendicular wall. This additional resistance by the perpendicular wall increases the strength of structural walls. The objective of this study is to evaluate the effective widths of flanged walls with different aspect ratios by using FEM analyses. the results from finite element method are compared with effective flange widths of some code provisions.

  • PDF

베이직 팬츠의 허리선 위치(位置)와 라운드 벨트 폭(幅)의 변화(變化)에 따른 시각적(視覺的) 이미지 (A Study of the Visual Image by Variations in the Location of the Waistline and the Width of the Round Belt of the Basic Pants)

  • 김지영;이정순;한경희
    • 패션비즈니스
    • /
    • 제10권5호
    • /
    • pp.15-27
    • /
    • 2006
  • The purpose of this study is to evaluate the differences of visual image by variations in the location of the waistline and the width of the round belt of the basic pants. The stimuli are 21 samples: 7 variations of the location of the waistline and 3 variations of the width of the belt. The data has been obtained from 35 fashion design majors. The data has analyzed by frequency, factor analysis, anova, scheffe's test and the MCA method. The visual image by the location of waistline and the width of belt are composed of 3 factors : modernity, comfort and attraction factor. In these factors, modernity factor is estimated as the most important factor. The visual image is modern and attractive as the location of waist line goes down. And when the location of waist line is in the position of natural waist belt, belt of 3.2cm width is visually effective. Belt of 4.2cm width is effective except the position of natural waist belt. The interaction effects between the location of the waistline and the width of the belt have significant differences in comfort and attraction factors. As the main effect, significant differences were observed in all of the three factors according to the location of waistline and the width of belt.

폭두께비가 큰 각형CFT 단주의 설계식 (Design Equation for Square CFT Columns with Large Width-to-Thickness Ratio)

  • 김선희;최영환;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.537-544
    • /
    • 2009
  • AISC(2005)나 KBC(2005)등의 기준에서는 콘크리트 충전 강관(Concrete Filled Steel Tube) 기둥의 내력산정에서 폭두께비의 제한을 두고 있으며 최대 폭두께비를 초과하는 기둥에 대해서는 설계식을 제시하지 않고 있다. 본 연구는 stiffened (양단지지) 플레이트에서는 좌굴이 발생하더라도 바로 내력저하가 발생하지 않고 상당한 양의 좌굴 후 강도를 발휘할 수 있어 폭두께비가 큰 강관을 사용하는 것이 경제적일 수 있다는 점을 착안, 유효폭 개념을 도입해서 폭두께비가 큰 각형 CFT의 강도를 계산할 수 있는 설계식을 제안하였다. AISC 2005, KBC 2005와 본 연구에서 제안한 식을, 폭두께비를 변수로 수행한 4개의 각형 CFT 기둥 실험결과와 비교하였며 제안된 설계식의 적용가능성을 확인하였다. 이에 Uy(2005), Dalin Liu(2005)는 폭두께비가 큰 단주 CFT에 한에서 선행 연구된 실험데이타를 근거로 제안 설계식을 단순적용 하였다. 폭두께비가 초과된 각형CFT 단주를 검토 대상기본으로 1. 용접 조립된 정사각형 단면 2. 모살용접된 정사각형 단면 (b/t 60mm. 80mm, 100mm) 3. 한 폭면의 폭두께비가 초과하는 직사각형단면의 (b/t 45.5) 실험체를 선정하여 제안식의 타당성을 검토해 보고자 한다.

Ultimate capacity of welded box section columns with slender plate elements

  • Shen, Hong-Xia
    • Steel and Composite Structures
    • /
    • 제13권1호
    • /
    • pp.15-33
    • /
    • 2012
  • For an axially loaded box-shaped member, the width-to-thickness ratio of the plate elements preferably should not be greater than 40 for Q235 steel grades in accordance with the Chinese code GB50017-2003. However, in practical engineering the plate width-to-thickness ratio is up to 120, much more than the limiting value. In this paper, a 3D nonlinear finite element model is developed that accounts for both geometrical imperfections and residual stresses and the ultimate capacity of welded built-up box columns, with larger width-to-thickness ratios of 60, 70, 80, and 100, is simulated. At the same time, the interaction buckling strength of these members is determined using the effective width method recommended in the Chinese code GB50018-2002, Eurocode 3 EN1993-1 and American standard ANSI/AISC 360-10 and the direct strength method developed in recent years. The studies show that the finite element model proposed can simulate the behavior of nonlinear buckling of axially loaded box-shaped members very well. The width-to-thickness ratio of the plate elements in welded box section columns can be enlarged up to 100 for Q235 steel grades. Good agreements are observed between the results obtained from the FEM and direct strength method. The modified direct strength method provides a better estimation of the column strength compared to the direct strength method over the full range of plate width-to-thickness ratio. The Chinese code and Eurocode 3 are overly conservative prediction of column capacity while the American standard provides a better prediction and is slightly conservative for b/t = 60. Therefore, it is suggested that the modified direct strength method should be adopted when revising the Chinese code.

차폐된 서스펜디드 섭스테레이트 코플래너 도파관 해석 (Analysis of the shielded suspended substrate coplanar waveguide)

  • 안광은;이상설
    • 전자공학회논문지A
    • /
    • 제32A권4호
    • /
    • pp.40-46
    • /
    • 1995
  • The characteristics of the shielded suspended substrate coplanar waveguide(SSCPW) are analyzed by applying the point matchning method to the quasi-TEM mode approximation. The characteristic impedances and the effective dielectric constants are also calculated by changing the height of air and dielectric layer, and the strip width of SSCPW. Approaching the side strip width of SSCPW to zero, values of characteristic impedances and effective dielectric constants are agreed well with the results obtained by the variational method.

  • PDF

열연강판 선후단부 폭 정밀도 개선을 위한 최적 엣저롤 개도 제어 (Dynamic Edger Control for the Precise Width Control at the Head, and Tail Ends of Hot Strip)

  • 천명식;이준정;문영훈
    • 대한기계학회논문집A
    • /
    • 제23권7호
    • /
    • pp.1196-1204
    • /
    • 1999
  • adaption of the model predictions is highly desirable. In general, the width deviation at the head and tail ends of strip may be different from that of the steady state region. Therefore, the dynamic edger corrections can be used to compensate the width deviations which would otherwise occur. For the precise width control, the effect of edger roll gap and rolling conditions on the width deviation of head and tail ends of strip has been investigated and the effective method to decrease width deviation has been proposed. On-line application of dynamic edger control method in this study shows about 50% width compensation at the head end of the strip, and near perfect compensation at the tail end of strip.