• Title/Summary/Keyword: Effective Flow Area

Search Result 468, Processing Time 0.028 seconds

A Study of Cooldown Performance of Shutdown Cooling System of Korea Next Generation Reactor (차세대 원자로 정지냉각계통의 냉각 성능에 대한 연구)

  • 유성연;이상섭
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.525-532
    • /
    • 1999
  • The standardized Korea Next Generation Reactor (KNGR) NSSS has developed in the basis of the ABB-CE System 80+ design concept. In this study, several regulatory requirements for the KNGR shutdown cooling system (SCS) operation are investigated. The purpose of this study is to establish the technical self-reliance for SCS design by supporting fundamental data such as SDCHX effective area and reactor CCW flow rate. Thermal power of KNGR would be increased to about 4,000 $MW_{th}$ in comparison with thermal power 2.825 $MW_{th}$ of UCN 3&4, therefore, SCS design data shall b recalculated by using the KDESCENT Code, which could evaluate cooling capability of SCS. It is found that SCS minimum flow rate is able to remove the primary sensible heat. Reviewing the major components such as heat exchanger, pump, value, and operating procedure, it is concluded as follows.

  • PDF

Improvement of Cognitive Rehabilitation Method using K-means Algorithm (K-MEANS 알고리즘을 이용한 인지 재활 훈련 방법의 개선)

  • Cho, Ha-Yeon;Lee, Hyeok-Min;Moon, Ho-Sang;Shin, Sung-Wook;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.259-268
    • /
    • 2018
  • The purpose of this study is to propose a training method customized to the level of cognitive abilities to increase users' interest and engagement while using cognitive function training contents. The level of cognitive ability of the users was based on the clustering based on the users' information and Mini-Mental Statue Examination-Korea Child test score using the K-means algorithm applied collaborative filtering. The results were applied to the integrated cognitive function training system, and the contents order and difficulty level of the cognitive function training area were recommended to the user's cognitive ability level. Particularly, the contents difficulty control was designed to give a high immersion feeling by applying the 'flow theory' method that users can repeatedly feel tension and comfort. In conclusion, the user-customized cognitive function training method proposed in this paper can be expected to be more effective and rehabilitative results than existing therapists' subjective setting of contents order and difficulty level.

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.

Geostrophic Response of the Yellow Sea to Cyclone Passage

  • Oh, Im-Sang;Subbotina, Marina M.
    • Journal of the korean society of oceanography
    • /
    • v.31 no.4
    • /
    • pp.183-195
    • /
    • 1996
  • A barotropic non-linear numerical model is used to study the response of the Yellow Sea to winter cyclone passage. Cyclones normally come from the outside of the western boundary, China, and pass the region eastward. The cyclone parameters used for the present study are the following: the intensity, i.e., the maximum wind speed of the cyclone; the effective radius corresponding to this maximum; and the translation speed. The equations of motion are integrated over the depth which is supposed to be a constant. The Gaussian function is used to define the stream function of the wind. The following results have been found. A northward current is generated by the frontal part of the cyclone near the western boundary. After the cyclone leaves the sea area, a southward current is generated by the rear part of the cyclone. After that, a northward current is generated once again due to the westward propagating Rossby waves. The response of the sea to the cyclone passage is strongly influenced by a steady current when the steady current and the current due to the cyclone wind are of the same order. The steady current diminishes the sea response and reduces the speed of the southward current, and enhances the northward current speed. The intensity and the translation speed of a cyclone also influence the flow pattern significantly.

  • PDF

Experimental Approach for Water Discharge Characteristics at PEMFC by using Neutron Imaging Technique considered Neutron Flux and Linear Attenuation Coefficient of Thermal Neutron Correction at NRF, HANARO (중성자속 및 선형 흡수 계수 보정을 고려한 중성자영상법을 이용한 PEMFC 내의 물 배출 특성에 관한 실험적 연구)

  • Kim, Tae-Joo;Kim, Jong-Rok;Kim, Moo-Hwan;Sim, Cheul-Muu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3418-3422
    • /
    • 2007
  • The neutron imaging technique was used to investigate the water discharge characteristics at PEMFC. Prior to investigation of water discharge characteristics, the linear attenuation coefficient for water at Neutron Radiography Facility (NRF) was calibrated. The feasibility test apparatus was consisted of pressurized air and water in order to simulate the actual operating PEMFC. The feasibility tests have been performed at 1-parallel serpentine type with 100 $cm^2$ active area and different air flow rate (1, 2, and 4 lpm). The total water volume variations at each condition were calculated from the neutron images. The water at channel is well discharged as soon as supplying the pressurized air into the PEMFC. However, because the water at MEA isn't removed the total water volume is constant after 150. Therefore more effective method is needed in order to discharge water at MEA, and the neutron imaging technique is helpful for it.

  • PDF

Preparation and Characterization of Porous Glass in $Na_2O-B_2O_3-SiO_2$ System ; Addition Effects of $ZrO_2$ and MgO (분상법을 이용한 봉규산염계 다공질 유리의 제조 및 특성;$ZrO_2$와 MgO 첨가 영향)

  • 김영선;최세영
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.385-393
    • /
    • 1995
  • Akali-resistant porous glass was prepared by phase separation in Na2O-B2O3-SiO2 system containing ZrO2 and MgO. ZrO2 was added for alkali-resistance and MgO for anti-cracking during leaching. Optimal content of ZrO2 for alkali-resistance was 7wt% and devitrification by heat treatment resulted from further addition. Pore size and pore volume were decreased and specific surface area was increased with ZrO2 addition due to depression in phase separation. Addition of 3mol% MgO to mother glass containing 7wt% ZrO2 was effective for anti-crack during leaching. In this case, with phase separation at 55$0^{\circ}C$ and 5$25^{\circ}C$ for 20 hrs. crack-free porous glasses could be prepared. The relation between pore size r and heat treatment time t at 55$0^{\circ}C$ was D=25.58+18.16t. According to measurement of gas permeability, the mechanism of gas permeation was Knudsen flow. N2 and He permeability of porous glass which was prepared by heat treatment at 55$0^{\circ}C$ for 20 hrs. were 0.843$\times$10-7mol/$m^2$.s.Pa and 2.161$\times$10-7mol/$m^2$.s.Pa respectively.

  • PDF

Characteristics of the Multi-kW Class Polymer Electrolyte Membrane Fuel Cell Stack for a Hybrid Electric Golf Cart

  • I.H. Oh;S.J. Shin;J.H. Jo;Park, S.K.;H.Y. Ha;S.A. Hong;S.Y. Ahn;Lee, Y.C.;S.A. Cho
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.254-261
    • /
    • 2002
  • The fabrication method for the main components of the polymer electrolyte membrane fuel cell stack such as electrodes, membrane-electrode assemblies, and bipolar plates was established for the effective electrode area of 240 ㎠. A counter-flow type 100-cell stack was fabricated by using the above components and then a maximum power of 7.44 kW for H$_2$/O$_2$ and 5.56 kW for H$_2$/air could be obtained at 70$\^{C}$ and 1 atm. It was seen that the distribution of the OCV for unit cells in the stack was uniform but the voltage deviation increased as the load increased due to the IR drop and the electrode polarization. The stack was applied to the power source of the fuel cell/battery hybrid electric golf car. It produced about 1 kW at a room temperature operation during the test run, which occupied about 43% of the total power required by the 2.3 kW motor.

Proposal on the Method of Regulating Ascending Kidney Water and Descending Heart Fire -through pharmacopuncture technique- (수승화강(水升火降) 조절법(調節法)(수화조절법(水火調節法))에 대한 제언 -약침을 이용하여-)

  • Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.10 no.3
    • /
    • pp.149-155
    • /
    • 2007
  • Objectives The purpose of this study is aimed at diagnosing and suggesting treatment plans for commonly seen clinical manifestation of heat symptom in the upper body and coldness in the lower body, also known as hot above, cold below syndrome. Methods Various reasons attribute to the presence of hot above, cold below syndrome, but mainly contributed by blockage of normal Qi flow by abnormality of heart-kidney root, spleen-stomach axis, and liver-lung axis. Diagnosing these abnormalities and timely alleviation to the healthy state is presented in the study. Results 1For heat in the upper body, Huang Lian Jie Du Tang(黃連解毒湯), CF, or JsD pharmacopuctures are injected on GB21, GB20. Qi stagnation in the thoracic area is treated with BUM injection on CV17. For impairment of transportation and transformation in the middle energizer, BUM pharmacopuncture is injected on CV12. Coldness in the lower energizer was relieved by bee venom or Sweet BV(Bee Venom free from enzymes) on CV6. Conclusion Above proposed methods of regulating water-fire were effective in treating hot above, cold below syndrome in clinical manifestations. But once the symptom subsides, treatment focused on eliminating innate cause should be rendered to achieve more successful results.

A Study of the Thermal Analysis of Horizontal Fillet Joints by Considering the Bead Shape in GMA Welding (GMA 용접에서 비드형상을 고려한 수평필릿용접부의 온도해석에 관한 연구)

  • Jo, Si-Hun;Kim, Jae-Ung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.71-78
    • /
    • 2001
  • In GMA(Gas Metal Arc)Welding, the weld size that is a locally melted area of a workpiece is one of the most important considerations in determining the strength of a welded structure. Variations in the weld power and the welding heat flux may affect the weld pool formation and ultimately the size of the weld. Therefore, an accurate prediction of the weld size requires a precise analysis of the weld thermal cycle. In this study, a model which can estimate the weld bead geometry and a method for thermal analysis, including the model, are suggested. In order to analyze the weld bead geometry, a mathematical model was developed with transformed coordinates to apply to the horizontal fillet joints. A heat flow analysis was performed with a two dimensional finite element model that was adopted for computing the base metal melting zone. The reliability of the proposed model and the thermal analysis was evaluated through experiments, and the results showed that the proposed model was very effective for predicting the weld bead shape and good correspondence in melting zone of the base metal.

  • PDF

A CLV (Customer Lifetime Value) model in the wireless telecommunication industry

  • Hyunseok Hwang;Kim, Suyeon;Euiho Suh
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.11a
    • /
    • pp.187-190
    • /
    • 2003
  • Since the early 1980s, the concept of relationship management in marketing area has gained its importance. Acquiring and retaining the most profitable customers are serious concerns of a company to perform more targeted marketing campaigns. For effective CRM (Customer Relationship Management), it is important to gather information on customer value. Many researches have been performed to calculate customer value based on CLV (Customer Lifetime Value). It, however, has some limitations. It is difficult to consider the churn of customers, because the previous prediction models have focused mainly on expected future cash flow derived from customers'past profit contribution. In this paper we suggest a CLV model considering past profit contribution, potential benefit, and churn probability of a customer. We also cover a framework for analyzing customer value and segmenting customers based on their value. Customer value is classified into three categories: current value, potential value and customer loyalty. Customers are segmented according to the three categories of customer value. A case study on calculating customer value of a wireless communication company will be illustrated.

  • PDF