• Title/Summary/Keyword: Effective Flow Area

Search Result 468, Processing Time 0.031 seconds

Influences of Vegetation Invasion on Channel Changes in the Deposition Area of Torrential Stream (계상퇴적지내의 식생침입이 유로변동에 미치는 영향)

  • Ma, Ho-Seop;Lee, Heon-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.3
    • /
    • pp.12-19
    • /
    • 2000
  • The purpose of this study is to evaluate the channel changes according to the temporal and spatial distribution of the deposition area by the vegetation invasion in Kyesung-river. The deposition area mainly occurred by landslide and debris flow from the headwater channel. And also the movement of subsequent downstream depends upon the site of deposits by a varity erosional processes. As the age of deposition area is older, it had a tendency to stable by plant invasion relatively. The vegetations grown in deposition area were very effective to estimate a historical deformation process of river-bed occurred by landslide. The vegetations around deposition area consisted of the same as tree species grown in forest area of circumference like Pinus densiflora, Styrax japonica, Quercus acutissima and Salix gracilistyla. If the torrential stream is flooding, the deposition area of 1 to 5 years can be change to the channel easily. Deposition area of 11 to 23 years had a high river-bed because it passed long time since deposited, and amount of sedimention is much more in wide than in narrow channel. It is consider that the change of channel had many influenced by the span of survial time, scale and movement frequency of deposition area after the vegetation invasion.

  • PDF

Geophysical well logs in basaltic area, Jeju Island (제주 현무암 지역의 용암분출에 따른 물리검층 반응의 특성 고찰)

  • Hwang Seho;Shim Jehyun;Park Inhwa;Choi Sun Young;Park Ki Hwa;Koh Gi Won
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.55-71
    • /
    • 2005
  • Jeju Island is mainly composed of basaltic lava flows and subordinate amounts of volcaniclastic sedimentary rocks. Jeju Province operates the monitoring wells for seawater intrusion problems around Jeju Island to evaluate of groundwater resources in coastal area. Various surveys and monitoring have been performed in boreholes, and also conventional geophysical well loggings conducted to identify basalt sequences and assess seawater intrusion problems. Various conventional geophysical well logs, including radioactive logs, electrical log, caliper log, and temperature and conductivity log and heat-pulse flowmeter log were obtained in 29 boreholes. The results of geophysical well loggings for saturated rocks are interesting and consistent. Natural gamma logs are useful in basalt sequences to sedimentary interbeds, unconsolidated U formation, and seoguipo formation with higher natural gamma log regardless of saturated or unsaturated basalts. Neutron logs are very effective to discriminate among individual lava flows, flow breaks, and sedimentary interbeds in saturated formation. In hyalocastite, porosity is high and resistivity is low, and we think that hyalocastite is a major pathway of fluid flow. In trachybasalt, porosity has a wide range and resistivity is high. In sedimentary interbeds, unconsolidated U formation and seoguipo formation, porosity is high and resistivity is low. The temperature logs in eastern area in Jeju are useful to interpret the hydrogeological unit and evaluate seawater intrusion in Suan area.

  • PDF

Estimation of 3-D Hydraulic Conductivity Tensor for a Cretaceous Granitic Rock Mass: A Case Study of the Gyeongsang Basin, Korea (경상분지 백악기 화강암 암반에 대한 삼차원 수리전도텐서 추정사례)

  • Um, Jeong-Gi;Lee, Dahye
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.41-57
    • /
    • 2022
  • A workflow is presented to estimate the size of a representative elementary volume and 3-D hydraulic conductivity tensor based on fluid flow analysis for a discrete fracture network (DFN). A case study is considered for a Cretaceous granitic rock mass at Gijang in Busan, Korea. The intensity and size of joints were calibrated using the first invariant of the fracture tensor for the 2-D DFN of the study area. Effective hydraulic apertures were obtained by analyzing the results of field packer tests. The representative elementary volume of the 2-D DFN was determined to be 20 m square by investigating the variations in the directional hydraulic conductivity for blocks of different sizes. The directional hydraulic conductivities calculated from the 2-D DFN exhibited strong anisotropy related to the hydraulic behavior of the study area. The 3-D hydraulic conductivity tensor for the fractured rock mass of the study area was estimated from the directional block conductivities of the 2-D DFN blocks generated for various directions in 3-D. The orientations of the principal components of the 3-D hydraulic conductivity tensor were found to be identical to those of delineated joint sets in the study area.

Determination of Floodplain Restoration Area Based on Old Maps and Analysis on Flood Storage Effects of Flood Mitigation Sections (고지도를 활용한 홍수터 복원 구역 선정 및 홍수완충공간의 홍수 저류효과 분석)

  • Dong-jin Lee;Un Ji;Sanghyuk Kim;Hong-Kyu Ahn;Eun-kyung Jang
    • Ecology and Resilient Infrastructure
    • /
    • v.10 no.2
    • /
    • pp.40-49
    • /
    • 2023
  • To reduce the damage of extreme flooding caused by climate change and to create flood mitigation sections in a nature-friendly riparian area, it is necessary to restore the floodplain area by referring to the past floodplain section of the current inland waterfront area before the levee was built. This study proposed a method of selecting a location for floodplain restoration using old maps of the Geum River study section and analyzed the effect of flood level reduction through unsteady flow numerical simulations using the floodplain as a flood mitigation space. As a result of analyzing changes in the river areas using old maps, the river section was estimated to gradually reduce by 27.8% (1,059,380 m2) in 2020 compared to 1919, and it was found to have an effective storage capacity of 2,200,868 m3 when restored to offline storage. The flood level and discharge control effects analyzed based on HEC-RAS unsteady flow simulation were 16 cm and 219.01 m3/s, respectively, in the downstream cross-section. In the numerical simulation in this paper, the flood mitigation space was applied as an offline reservoir. The effect of reducing the flood level may differ if levee retreat/relocation is applied.

Determination of Key Factors for the Pedestrian LOS Introducing the Accessibility Index (접근성 지표를 도입한 보행로 서비스 수준의 영향요인 규명)

  • CHOI, Sung Taek;CHOO, Sang Ho;JANG, Jin Young
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.6
    • /
    • pp.584-597
    • /
    • 2015
  • A considerable amount of literature has been published on pedestrian LOS. So far, however, there is a limitation that LOS analysis methodologies has concentrated on quantitative variables such as pedestrian flow rate, speed and space. This paper intended to suggest the accessibility variable which can not be considered on previous study. The factor was defined and quantified using public transport attributes in particular. This study was carried out in three phases: 1. defined accessibility employing public mode location and service information. 2. investigated the relationship between accessibility and pedestrian flow rate 3. developed the model to establish the factors affected to pedestrian LOS. The results showed that accessibility, walkway attribute and land use type affected the pedestrian LOS. Especially, accessibility and commercial area ratio had negative relationship with LOS. Futhermore, pedestrian LOS declined when obstacle of bus station located on the walkway. On the contrary, LOS was upgraded when sufficient effective width or residential area was secured. These results can receive considerable critical attentions related to determination of pedestrian LOS or effective walkway width.

A Case Study for the Determination of Time Distribution of Frequency Based Rainfall (확률강우의 적정시간분포 결정에 관한 연구)

  • Lee, Jeong Ki;Kim, Hung Soo;Kang, In Joo
    • Journal of Wetlands Research
    • /
    • v.6 no.3
    • /
    • pp.71-81
    • /
    • 2004
  • In recent, the heavy rainfall is frequently occurred and the damage tends to be increased. So, more careful hydrologic analysis is required for the designs of the hydraulic or disaster prevention structures. The time distribution of a rainfall is one of the important factors for the estimation of peak flow in hydrologic and hydraulic designs. This study is to suggest a methodology for the estimation of a rainfall time distribution which can reflect the meteorologic and topographical characteristics of Daejeon area. We collect the 34 years' rainfall data recorded in the range of 1969 to 2002 for Daejeon area and we performed the rainfall analysis with the data in between May and October of each year. According to the Huff method, the collected data corresponds to the first quartile which the rainfall is concentrated in the primary stage but the suggested method shows the different rainfall distribution with the Huff method in time. The reason is that the Huff method determines the quartile in each storm event while the suggested one determines it by estimating the dimensionless distribution of rainfall in duration after the accumulation of rainfall in time. The rainfall distributions estimated by two methodologies were applied to the Gabcheon basin in Daejeon area for the estimation of flood flow. Here we use the SCS method for the effective rainfall and unit hydrograph for the flood discharge. As the results, the peak flow for 24-hour of 100-year frequency was estimated as a $3421.20m^3/sec$ by the Huff method and $3493.38m^3/sec$ by the suggested one. We can see the difference of $72.18m^3/sec$ in between two methods and thus we may carefully determine the rainfall time distribution and compute the effective rainfall for the estimation of the peak flow.

  • PDF

Estimation of Flow Loads Characteristics each Sub-watershed for TMDL (TMDL 적용을 위한 소유역별 유출부하 특성 분석)

  • Kim, Joo-Hun;Kim, Kyung-Tak;Lee, Jin-Won
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.443-453
    • /
    • 2011
  • This research aims at suggesting the mitigation measures of decreasing pollution by analyzing land cover characteristics according to subwatershed, and non-pollutant load characteristics occurring in each subwatershed. Mushim-cheon is selected as a research area, and HyGIS-SWAT is used as a water quality model. This research analyzed outflow load characteristics by classifying land cover, which has over 50% classified items, into a city area, a farmland area and a forest area. The result shows that the yearly occurrence load quantity represents a farmland area, a forest area and a city area in order. In subwatershed-2, occurrence load quantity is analyzed by setting up a buffer zone in the center of stream, and by changing a farmland area into a natural grass land. Therefore, a farmland area in a subwatershed changes 36.6% into 27.9% and 15.3% comparing to previous land cover change. In the analysis of sediment loads occurrence quantity and nutritive salt load occurrence quantity in subwatershed-2, sediment loads occurrence quantity decreases 52% to about 47%, and nutritive salt load decreases 49% and 34% in compare with previous change. Hereafter, this research will set up the mitigation measures scenario, and find out which is more effective for the mitigation measures.

The Effects of a Simulation-Based High Flow Nasal Cannula Oxygen Therapy Training Program on the Knowledge, Clinical Performance and Educational Satisfaction of Clinical Nurses (시뮬레이션기반 고유량산소요법 교육 프로그램이 임상간호사의 지식, 임상수행능력 및 교육만족도에 미치는 효과)

  • Jang, Kyung Soon;Ryu, Kyeong Hee;Kang, Hyeon Mo;Kang, In Hwa;Kwon, Jeong Hui;Lee, Gyeong Mi;Nam, Yun Jung;Seo, Mi Hye;Kim, Ji Yeon;Jung, Ji Yun;Kim, Hyun Ji;Bae, Hye Min
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.47-58
    • /
    • 2020
  • Purpose: The aim of this study was to develop a simulation-based High Flow Nasal Cannula Oxygen Therapy training program based on NLN/ISF to identify the effect on knowledge, clinical performance, and educational satisfaction compared to a group who had traditional High Flow Nasal Cannula Oxygen Therapy training after applying it to clinical nurses. Methods: 31 experimental groups and 33 control groups were conducted from August 2019 to September 2019 for inexperienced nurses over 4 months to 5 years with no experience using high-flow oxygen therapy. Educational programs were developed in scenarios according to Airvo2 and Optiflow, such as facilitator, participant, educational condition, design, characteristics, and educational outcomes. The education application was conducted in advanced for knowledge and clinical performance ability after watching therapy video. Since then, a total of 90 minutes have been conducted for respiratory failure theory training, airvo2 and optiflow simulation training, and debriefing. After applying the education, the medical institution measured nurses' knowledge, clinical performance, and education satisfaction. Data were analyzed using descriptive statistics, with the SPSS/WIN 22.0 program. Results: Both knowledge and educational satisfaction were higher in the experimental group than in the control group (t=-14.09, p<.001), (t=-12.99, p<.001). The clinical performance for both use of Optiflow and Airvo2 were higher in the experimental group than in the control group (t=-11.39, p<.001), (t=-11.38, p<.001). Conclusion: Results showed that the simulation-based High Flow Nasal Cannula Oxygen Therapy training was effective with the experimental group having increased scores for every area of this study.

Effect of Non-perceptual Sensory Stimulation Intensity Using Transcutaneous Electrical Nerve Stimulation on Cerebral Blood Flow (경피신경전기자극기를 이용한 비지각적 감각자극 강도가 뇌혈류에 미치는 영향)

  • Ju-Yeon Jung;Chang-Ki Kang
    • Science of Emotion and Sensibility
    • /
    • v.27 no.2
    • /
    • pp.81-90
    • /
    • 2024
  • In this study, we aimed to determine the effect on cerebral blood vessels of various stimulus intensities using transcutaneous electrical nerve stimulation (TENS). In particular, we wanted to monitor changes in blood flow and structural changes in the blood vessels in the common carotid artery (CCA) through low-intensity electrical stimulation that can cause non-perceptual sensory stimulation. Twenty-four healthy adults in their 20s participated in this study. Three stimulus intensities (below the sensory threshold, at the sensory threshold, and above the sensory threshold) were applied in random order. Changes in blood flow velocity according to the intensity of TENS stimulus were measured by placing the Doppler ultrasound transducer 1 cm below the CCA bifurcation, and the vascular structure was measured using B-mode imaging. C-mode Doppler and B-mode images were acquired before, during, and after the intervention for each stimulus, and changes in blood pressure were measured in each session. As a result, it was confirmed that peak systolic velocity (PSV) decreased significantly after the intervention in non-perceived sensory stimulation below the threshold, compared to other thresholds (p = .008). In particular, the PSV decreased by 3.04% on average compared to before stimulation (p = .011). However, there was no significant change in the CCA diameters before and after stimulation at all intensities. It was found that short-term, non-perceptual sensory stimulation was effective in reducing the blood flow rate without causing significant changes in either the blood vessel diameter or blood pressure. This change appears to be caused by a decrease in blood flow due to the effect of subtle vasodilation at non-perceptual sensory stimulation, and at stimulation intensity higher than that, the sympathetic nerves in the blood vessels are stimulated excessively and the blood vessels constrict. Therefore, this study can be rated as an important attempt to control blood flow through stimulation without such a psychological burden and sensory discomfort in the carotid area.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.