• 제목/요약/키워드: Effect Measurement

검색결과 6,965건 처리시간 0.033초

목 폄 시 탄력성 테이프의 신장력 차이가 전방머리자세 증후군의 근수축 개시시간에 미치는 영향 (The Effect of Different Elastic Tape Expansibilities on the Onset Time of Muscle Contraction during Neck Extension for Forward Head Posture Syndrome)

  • 윤정규
    • PNF and Movement
    • /
    • 제20권3호
    • /
    • pp.331-340
    • /
    • 2022
  • Purpose: Thisstudy aimed to identify the effect of varying the expansibility of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. Methods: Forty-five young adults with forward head posture syndrome volunteered to participate and were randomly assigned to one of three groups according to the expansibility of the elastic tape (25%, 50%, 75%). The onset time of muscle contraction for the neck extensor during neck extension was measured using an electromyographic system (Free EMG, BTS, Italy). Multivariate analysis of variance was employed to determine the effect of different expansibilities of elastic tape on the onset time of muscle contraction during neck extension for forward head posture syndrome. When there was a statistically significant difference by MANOVA, Scheffe was used as a post-hoc test. The level of significance was set at α=0.05. Results: In the comparison of the onset time of muscle contraction of varying elastic tape expansibilities and measurement times, there was a significant difference between the groups (Lt. UT, Lt. SCM, Rt. SCM) (p < 0.05), but there was no significant difference in the interaction between the measurement time and the group, between the measurement time (p > 0.05). Conclusion: In the neck extension, 75% of the tape extensibility in the Lt. UT and both SCM shortened the muscle contraction onset time.

루프임피던스와 부하상태의 상관관계 분석 (Correlation Analysis about Loop Impedance and Load Condition)

  • 정진수;김한상;김선구;한운기;박찬엄
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.342-346
    • /
    • 2012
  • This paper presents a loop impedance(inner loop impedance & external impedance) measurement method in TN system. When the measurement of a loop impedance then the measurement result have a some error by load condition. In this paper suggest the loop impedance measurement on actual loading condition by two experiment. one was laboratory condition and the other was the actual measurement on site. Analysis result, measuring error by load condition has not effect on measuring loop impedance.

PIMS 모형(模型)의 응용(應用)에 의한 측정투자효과분석(測定投資效果分析) 우리나라 주요기업을 중심으로 (Effect Analysis of Measurement-related Investment by the PIMS model With Reference to Korean Industrial Firms)

  • 김동진;안웅환
    • 품질경영학회지
    • /
    • 제18권2호
    • /
    • pp.117-126
    • /
    • 1990
  • The Purpose of this study is to grasp the general effects of measurement-related investment by industrial firms. We presupposed the hypothesis that the measurement-related investment affects the decrease of product inferiority rates and analyzed the investigation results by means of PIMS(Profit Improvement of Market Strategy) model. As the results, we found out that the firms with positive measurement-related investment showed for less inferiority rates of products considerably. This study put an emphasis on the verification results showing that the considerable increase of measurement-related investment decreases the product inferiority rate by the statistical methods.

  • PDF

측정 ANOVA의 분산성분에 의한 게이지 R&R 추정 (Estimation of Gauge R&R by Variance Components of Measurement ANOVA)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.199-205
    • /
    • 2010
  • The research proposes the three-factor random measurement models for estimating the precision about operator, part, tool, and various measurement environments. The combined model with crossed and nested factors is developed to analyze the approximate F test by degrees of freedom given by Satterthwaite and point estimation of precisions from expected mean square. The model developed in this paper can be extended to the three useful models according to the type of nested designs. The study also provides the three-step procedures to evaluate the measurement precisions using three indexes such as SNR(Signal-To-Noise Ratio), R&R TR(Reproducibility&Repeatability-To-Total Precision Ratio), and PTR(Precision-To-Tolerance Ratio), The procedures include the identification of resolution, the improvement of R&R reduction, and the evaluation of precision effect.

MOSFET 검출기의 방사선 측정 기법 (A Methodology of Radiation Measurement of MOSFET Dosimeter)

  • 노영찬;이상용;강필현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF

측정오차를 고려한 최적 공정평균의 경제적 설정 - 축차검사의 활용 (Economic Selection of the Optimal Process Mean Using Sequential Inspection to Reduce the Effect of Measurement Errors)

  • 박환수;장영순
    • 품질경영학회지
    • /
    • 제34권2호
    • /
    • pp.12-21
    • /
    • 2006
  • This paper considers the problem of selecting the most profitable process mean for production processes where measurement errors exist in inspection systems. For such situations, a sequential inspection procedure is proposed to reduce measurement errors. The decision to accept, reject, or take an additional inspection of an item is made at every measurement point until the number of repeated measurements reaches its upper bound. An expected profit model is constructed and the optimal process mean, the cut-off values, and the upper bound of the number of repeated measurements are obtained when accepted(rejected) items are sold at regular(reduced) price. A numerical study is performed to investigate the performance of the proposed procedure.

승강장 스크린 도어 시스템 특성 시험의 반복 측정에 의한 불확도 개선 고찰 (A study of improvement of uncertainty by repeated measurement for PSD(Platform Screen Door) Performance Test)

  • 온정근;김명룡;윤명상;김원경;원시태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1671-1674
    • /
    • 2007
  • A PSD system has a lot of characteristic for safety. Trust of performance test is very important. But PSD performance test has an effect on trust by proficiency of test staff because it is difficult to automate. In that specially the effort test, manual opening and shutting test and abrasion measurement, test staff is demanded for proficiency. Therefore the paper repeated measurement in same condition and studied proficient factor of examiner according to increased measurement counter. As a result, measurement uncertainty has improved.

  • PDF

잔향실법 흡음률 측정에 미치는 확산체의 영향 (The effect of diffusers on the measurement of sound absorption in a reverberation room)

  • 한희갑;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

방진장갑 진동 전달률 측정에서의 측정불확도 추정 (Estimation of the Measurement Uncertainty in Measuring the Vibration Transmissibility of Anti-vibration Gloves)

  • 홍석인;장한기;최석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.251-254
    • /
    • 2005
  • In this study vibration transmissibilities of the selected anti-vibration gloves were measured, and the measurement uncertainty was estimated. Since human factors such as palm size, gripping condition and dynamic properties of the hand-arm effect the measurement a lot, it is necessary to know ow much the uncertainty is. This study takes the measurement procedure suggested in ISO 10819. Three subjects Joined at each test and each anti-vibration glove was tested twice per a subject. Average and standard deviation of vibration transmissibility were calculated and uncertainty of them were estimated at 95% confidence level.

  • PDF

차음성능 측정에 있어서의 암소음의 영향의 저감 (2) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나 히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.441-444
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined through field measurements.

  • PDF