• Title/Summary/Keyword: Ecotect analysis

Search Result 19, Processing Time 0.034 seconds

A Study on the Calculation of Overshadowing Area by Ray-Tracing Method (Ray-Tracing Method를 이용한 일영면적 산정방식 고찰)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.36-41
    • /
    • 2011
  • Nowadays, the solar expose right is very important with people's life. Therefore, in calculating the sunshine hours, the point analysis and area analysis methods are used in previous studies. Previous two methods have merits and faults. Therefore, ray-tracing method is used as a alternative. Ray-tracing method is adopted by the software of Autodesk Ecotect which is a widely used program by the architectural company and academic university. In this study first, ray-tracing methodology is studied with how to calculate the overshadowing area and, secondly, the sensitivity of the two major factors, overshadowing accuracy and sky subdivision, is analyzed. With these results, appropriate application of the ray-tracing method is presented.

Energy Performance Analysis the Common House Pansang Type and Tower (공동주택의 판상형과 타워형 에너지 성능 비교 분석)

  • Yoon, Sung-Meen;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.57-64
    • /
    • 2013
  • This study focus on the analysis of the energy performance in accordance with apartment houses arrangement type by using Ecotect Analysis. Korea, energy-poor country, the rate of dependence on imports amount to 94%, have to reduce energy consumption part of building except in industry and transport which affect the economic. Apartment houses are built in various forms in order to reduce energy, are modelled in each window area ratio, shape, orientation, climate through simulation. Through this study, we can analyze energy performance by form, window area ratio, orientation, climate change and know the optimal elements by the form. In particular, although there have been studied research on the window area ratio and research related to the arrangement form, determined that the information on the regional climate characteristics and the direction of placement is less than existing research. To supplement those problem, adding to seven direction(West, S-60-W, S-30-W, South, S-30-E, S-60-E, East) and climatic element(southern region) is characteristic of this study. The form of apartment houses was modelled for apartment houses built in the 10 years since. And each modeling were analyzed by Ecotect Analysis.

Analysis of Daylight Distributions and Solar Radiation to Verify the Applicability of Blind PV Systems Using Simulation (블라인드PV 시스템의 적용성 검증을 위한 주광 특성 및 일사량 분석 시뮬레이션)

  • Hong, Seong-Kwan;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.1-9
    • /
    • 2011
  • Daylight provides residents with good visual environment. And available daylight in inside provides positive influence on psychological and physiological aspects. Also, sunlight can be converted directly into electricity using PV(photovoltaic) power generation. This study was to analyze characteristics of daylight distributions, calculate an amount of solar radiation and a PV power generation on the building facade using Radiance and Ecotect simulation programs. Ultimately, the purpose of this study is to verify the applicability of Blind PV systems.

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data - (요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Yun, Youngil;Cho, Juyoung;Lee, Hyowon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

An Analysis of Permanantly Shaded Areas and the Defect Rate of Landscape Trees in Apartment Complexes Using Daylight Simulations

  • Park, Sang Wook
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.3
    • /
    • pp.333-345
    • /
    • 2020
  • Background and objective: The purpose of this study was to provide basic data on trees that can be used for planting design and construction for permanently shaded areas by grasping the growth status of trees according to the daylight conditions of the outdoor spaces of apartment complexes. Methods: On the recently completed apartment complexes, daylight conditions were analyzed by using daylight simulations utilizing Solar Access Analysis of Ecotect Analysis. With a criteria for assessment of tree condition, the defect rate of trees planted in permanently shaded areas and green spaces with good daylight conditions was analyzed to suggest trees applicable to permanently shaded areas. The first tree survey was conducted from November 18, 2019 to February 15, 2020, focusing on trees planted in permanently shaded areas, and the second tree survey of all the trees planted on the study sites including permanently shaded areas was conducted from March 16 to March 30, 2020. Results: Evergreen trees which are classified as shade intolerant trees including Pinus densiflora, Thuja occidentalis, and Abies holophylla showed a higher defect rate of trees among the trees planted in permanently shaded areas. Taxus cuspidata, Zelkova serrata, Cornus kousa, Chionanthus retusus and Acer palmatum which are classified as shade tolerant trees and shade moderate tolerance trees seemed to be able to be used in the plant design of permanently shaded areas in apartment complexes because the trees showed good growth and a low tree defect rate. In addition, although it was excluded from the analysis due to a small number of samples, Sorbus commixta and Prunus cerasifera var. atropurpurea also can be used for planting in permanently shaded areas. Conclusion: The daylight simulation technique used to analyze permanent shaded areas in this study can be used as an analysis tool considering the daylight environment at the stages of design and construction, and additional research will be required to analyze tree growth according to daylight conditions through data accumulation and monitoring by managing records throughout the entire life cycle of trees in the process of planting and maintenance.

Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals (K 노인전문병원의 공간 통합도와 자연광의 상관관계 분석)

  • Moon, Sun-Young;Lee, Hyun-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2015
  • In case of Senior Hospitals, meticulous care is required in both amount and quality of natural lighting because of the semi-long term residence of patients. Natural lighting has a huge impact on the physical and psychological part for the seniors. Likewise, natural lighting is an important factor considered for hospital design because it can also effect hospitalization period of patients. Research subject was K Senior Hospital which was determined as the courtyard-type building made to provide healing environment through natural lighting. Analysis was performed by dividing the space of K Senior Hospital into Central Treatment Department directly used by patients, Outpatient Department(OPD), Ward Department, Common Use Department. Research was carried out in two ways of integration value analysis using SPACE SYNTAX and illumination intensity analysis using ECOTECT. K Senior Hospital intended to actively let in natural light through courtyard and to make patients exposed to natural light when they walk along the circuit corridor built around the courtyard. This environmental consideration affected the utilization rate of Common Use Department and residence time of patients raising the average of Common Use Department on every floor. As a resuit of this study presenting type C and type D, part of four types of illumination intensity, takes higher percentage of almost every spaces compare to the others therefore K Senior Hospital was designed on the assumption of healing environment composition through natural light. The result of this research would be used meaningfully in the space programming phase of Senior Hospitals in the future. Utilization rate can be adjusted using illumination intensity value in the space that integration rate should be planed to be high. The use(purpose) of space and integration rate can be used as a guideline to set illumination intensity of natural.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

Energy Efficiency Prediction Based on an Evolutionary Design of Incremental Granular Model (점증적 입자 모델의 진화론적 설계에 근거한 에너지효율 예측)

  • Yeom, Chan-Uk;Kwak, Keun-Chang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.47-51
    • /
    • 2018
  • This paper is concerned with an optimization design of Incremental Granular Model(IGM) based Genetic Algorithm (GA) as an evolutionary approach. The performance of IGM has been successfully demonstrated to various examples. However, the problem of IGM is that the same number of cluster in each context is determined. Also, fuzzification factor is set as typical value. In order to solve these problems, we develop a design method for optimizing the IGM to optimize the number of cluster centers in each context and the fuzzification factor. We perform energy analysis using 12 different building shapes simulated in Ecotect. The experimental results on energy efficiency data set of building revealed that the proposed GA-based IGM showed good performance in comparison with LR and IGM.