• Title/Summary/Keyword: Economical operation

Search Result 501, Processing Time 0.024 seconds

Development of simple and continuous microwave source using a microwave oven (전자오븐을 이용한 간편하고 연속적인 마이크로파 발생 장치 개발)

  • 권기청;김재현;김정희;이효석;전상진;허승회;최원호
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.290-295
    • /
    • 2000
  • In order to utilize as a pre-ionization means for reproducible ohmic plasma on KAIST-TOKAMAK, a simple, safe, economical and continuous microwave source has been developed using a home kitchen micro-wave oven. The magnetron used in the study can provide 500 W of power at 2.45 GHz. A conventional magnetron in a home kitchen microwave oven generates microwave for 8 ms at every 16 ms periodically due to the periodic (60 Hz) high voltage applied to the magnetron cathode. In order to generate continuous microwave which is suitable for tokamak pre-ionization, the magnetron operation circuit has been modified using a DC high voltage (5 kV, 1 A) power supply. It provides high-voltage with small ripple for magnetron cathode bias. Using the developed magnetron system, electron cyclotron resonace heated (ECH) plasmas were produced and the characteristics of the system were studied by diagnosing the ECH plasma using Langmuir probe and $H_{\alpha}$ emission diagnostics.

  • PDF

The Jet-fan Model Test for a Road Tunnel Ventilation (도로터널 제트팬 모형 실험)

  • Ryu, Jae-Hong;Yoo, Young-Ho;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.

Process Modeling and Economic Analysis of Hydrogen Production System on 500 kg-H2/d-class Green Hydrogen Station using Biogas (바이오가스 이용 500 kg-H2/d급 그린수소충전소의 수소추출시스템 공정모델링 및 경제성 분석)

  • Hong, Gi Hoon;Song, Hyoungwoon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.19-26
    • /
    • 2021
  • In this paper, we carried out the process modelling and economical analysis of the 500 kg-H2/d-class green hydrogen production system process based on biomethane from the Food Bio Energy Center in Chungju. As a result of economic analysis, the NPV(Net present value) after 15 years of operation is 3.831 billion won, the PI(Profitability index method) is 1.42. It was found that the project of 500 kg-H2/d-class green hydrogen production system has a 20.25% of IRR, which is higher than social discount rate of 4.5% and feasibility is ensured.

AMI System Using Smart Electricity Meter Embedded with Home Concentrate Unit (세대집중화장치를 포함하는 스마트 전력량계를 이용한 AMI 시스템)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.537-546
    • /
    • 2019
  • In this paper, a system that integrates a home concentrate unit(HCU) in a smart electricity meter to collects water, gas, hot water, and heating usage required for AMI has been proposed. The collected data could be transmitted to the in house display(IHD) and server to provide a more economical AMI system. The developed system is less expensive in the network configuration than the existing system, which could reduce the operating cost, and be easy to install. By applying the developed system, the usage of electricity, water, gas, hot water and heating could be measured and these make it easier to apply AMI system. The main contents of the development are the smart electricity meter and embedding of HCU into the smart electricity meter, and transferring these data to IHD and server to structure the AMI system. The each developed unit has been networked to structure the AMI system to perform the actual meter reading operation and show the result.

A Study on the Power Generation Compared to the Capacity of Power Generation Facilities by Energy Sources in Summer Season (하절기의 에너지원별 발전설비용량 대비 발전량에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.36-40
    • /
    • 2019
  • In this study, we compared the operational rates of natural gas, coal, nuclear power and renewable energy based on the data of power generation and power generation facilities produced in summer season(from June to August) during the last four years(2015~2018). Nuclear power and coal power, which are responsible for basic power generation, were guaranteed to be economical as the actual generation capacity remained 60% higher than the cost of power generation. On the other hand, natural gas generation and new renewable energy generation have a very low actual operation rate of 29.5% and 27.3% compared to investments in power generation facilities, making it difficult to lower the cost of power generation. However, coal generation has structural problems in terms of greenhouse gas, fine dust. On the other hand, natural gas generation is relatively low and even though it is safe, it is difficult to secure economic feasibility as it is bound by a peak power system. Therefore, it is only possible to achieve balanced development of energy sources when there is a change in the development policy.

On derivation the System Analysis and Evaluation Indicators of Blockchain-based Smart Electronic Transport Waybill Platform for Improvement of Logistics Service Operation Efficiency and Personal Information Security (물류 서비스 운영 효율과 개인정보 보안 향상을 위한 블록체인 기반 스마트 전자 운송장 플랫폼 시스템 분석 및 평가지표 도출에 관한 연구)

  • Park, Jae-Min;Won, JoNg-Woon;Seong, Ki-Deok;Kim, Young-Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.4
    • /
    • pp.75-86
    • /
    • 2020
  • With the advent of the 4.0 era of logistics due to the Fourth Industrial Revolution, infrastructures have been built to receive the same services online and offline. Logistics services affected by logistics 4.0 and IT technology are rapidly changing. Logistics services are developing using technologies such as big data, artificial intelligence, blockchain, Internet of things, and augmented reality. The convergence of logistics services and various IT new technologies is accelerating, and the development of data management solution technology has led to the emergence of electronic cargo waybill to replace paper cargo waybill. The electronic waybill was developed to supplement paper waybill that lack economical and safety. However, the electronic waybill that appeared to complement the paper waybill are also in need of complementation in terms of efficiency and reliability. New research is needed to ensure that electronic cargo waybill gain the trust of users and are actively utilized. To solve this problem, electronic cargo waybill that combine blockchain technology are being developed. This study aims to improve the reliability, operational efficiency and safety of blockchain electronic cargo waybill. The purpose of this study is to analyze the blockchain-based electronic cargo waybill system and to derive evaluation indicators for system supplementation.

Development of Artificial Intelligence Model for Outlet Temperature of Vaporizer (기화 설비의 토출 온도 예측을 위한 인공지능 모델 개발)

  • Lee, Sang-Hyun;Cho, Gi-Jung;Shin, Jong-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.85-92
    • /
    • 2021
  • Ambient Air Vaporizer (AAV) is an essential facility in the process of generating natural gas that uses air in the atmosphere as a medium for heat exchange to vaporize liquid natural gas into gas-state gas. AAV is more economical and eco-friendly in that it uses less energy compared to the previously used Submerged vaporizer (SMV) and Open-rack vaporizer (ORV). However, AAV is not often applied to actual processes because it is heavily affected by external environments such as atmospheric temperature and humidity. With insufficient operational experience and facility operations that rely on the intuition of the operator, the actual operation of AAV is very inefficient. To address these challenges, this paper proposes an artificial intelligence-based model that can intelligent AAV operations based on operational big data. The proposed artificial intelligence model is used deep neural networks, and the superiority of the artificial intelligence model is verified through multiple regression analysis and comparison. In this paper, the proposed model simulates based on data collected from real-world processes and compared to existing data, showing a 48.8% decrease in power usage compared to previous data. The techniques proposed in this paper can be used to improve the energy efficiency of the current natural gas generation process, and can be applied to other processes in the future.

Economy Analysis and Optimized Capacity Evaluation of Photovoltaic-Related Energy Storage System (태양광 에너지저장장치(ESS) 경제성 분석 및 최적 용량 평가)

  • Lee, Young-Hun;Sung, Tae-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.209-218
    • /
    • 2022
  • The purpose of this study is to analyze an economic assessment of PV-ESS systems based on the power generation performance data of solar power (PV) operating in domestic area, and to calculate the optimal capacity of the energy storage system. In this study, PVs in Gyeonggi-do, Jeollabuk-do, and Gyeongsangbuk-do were targeted, and PVs in this area were assumed to be installed on a general site, and the research was conducted by applying weights based on the facility's capacity. All the analysis was conducted using the actual amount of KPX transactions of PVs in 2019. In order to calculate the optimal capacity of PCS and BESS according to GHI, PV with a minimum/maximum/central value was selected by comparing the solar radiation before the horizontal plane between three years (2017-2019) of the location where PV was installed. As a result of the analysis, in Gyeonggi-do, if the REC weight decreases to 3.4 when there is no change in the cost of installing BESS and PCS, it is more economical to link BESS than PV alone operation of PV. In Jeollabuk-do, it was analyzed that if the REC weight was reduced to 3.6, it was more likely to link BESS than PV operated alone. In Gyeongsangbuk-do, it was analyzed that if the REC weight was reduced to 3.4, it was more likely to link BESS than PV operated alone.

Adsorption Characteristics of Heavy Metals by Various Forest Humic Substances

  • Ahn, Sye-Hee;Koo, Bon-Wook;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.73-82
    • /
    • 2003
  • Various forest humic substances were collected at different climate regions with different forest types, and adsorption of heavy metals such as Cu(II), Zn(II), Cd(II) and Cr(III) were characteristically conducted to obtain optimal adsorption conditions and to evaluate the removal efficiency of heavy metals by each forest humic substance. The adsorption isotherms for Cu(II), Zn(II), Cd(II) and Cr(III) conformed to Langmuir's equation. In the stirred reactor, the removal efficiencies of Cu(II), Zn(II) and Cd(II) by forest humic substances were more than 90% but that of Cr(III) was less than 60%. The adsorption capacities of heavy metals in the stirred reactor were considerably varied depending on the type of forest humic substances. Among humic substances, the one from deciduous forest at subtropical region showed the highest removal efficiency for Cu(II). There was no significant difference in removal efficiency by each heavy metal depending on reaction temperature ranged from 20 to 50oC except for Cr(III), and the adsorptions of Cu(II), Zn(II) and Cd(II) were occurred rapidly in the incipient stage within 10 min, while Cr(III) needed more reaction time to be adsorbed. The stirred and packed bed column reactors showed similar adsorption characteristics of heavy metals by humic substances, but the removal efficiency was considerably higher in the packed bed column reactor than in the stirred reactor. Therefore, in actual operation process, a continuous packed bed column reactor was more economical.

Refinement of Interpretation Method for Reliable Vs Profiling in Downhole Seismic Method (다운홀 시험에서 신뢰성 있는 전단파 속도 주상도 도출을 위한 해석 기법의 개선)

  • Bang, Eun-Seok;Kim, Dong-Soo;Yoon, Jong-Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.157-170
    • /
    • 2006
  • Downhole method is considered as giving a little unreliable Vs profile when the signal to noise ratio(S/N) is low and the travel time information is erroneous although it is economical and ease of operation. Direct method has been applied for obtaining adequate result in this case. But it is difficult to determine optimum result by using direct method which is subjective and considering straight ray path. Therefore, in this paper, Mean Refracted Ray Path Method(MRM) was proposed, which is automated and considering refracted ray path. Artificial travel time data adding some travel time error was generated by forward modeling based on Snell's Law and travel time data was also obtained from numerical signal traces using FEM modelling. Using these travel time data, reliability of MRM was verified in the manner of comparing the results determined by MRM with the model. Finally, proposed method was applied to the real field data and it was considered as improved method for obtaining the optimum result in downhole seismic method.