• 제목/요약/키워드: Economic loss

검색결과 1,363건 처리시간 0.032초

고온초전도 전력케이블 적용효과 검토 (A Study on the Application Effects of HTS Power Cable)

  • 성기철;조전욱;김해종;권영길;최상봉;류강식;김봉태;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.32-36
    • /
    • 2000
  • In this study, we performed the long-term expansion planning for the conceptual design of HTS power cable in Seoul area. In Korea, underground power cable has been required gradually with increasing demand of electric power transmission density and low loss characteristics in the comparison with a conventional power cables, so we assumed that the HTS power cable is applied between the downtown area and the outskirts of the city for the large power transmission capacity. This paper is to show the effects of HTS power cables in Seoul based on the power system analysis.

  • PDF

정적 전압의존형 부하모델을 적용한 B계수 산정법 (A Computation Method of B-coefficient With Static Voltage Dependent Load Model)

  • 이명환;채명석;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.218-220
    • /
    • 1997
  • In power system, economic dispatch problem is to minimize fuel cost with inequality constraints of generator output. To solve this problem it is very important to express power loss equation that have Quadratic function of generator power included B-coefficient. This paper presents a method in determining B-coefficient by use A-matrix that is calculated by power flow considering voltage dependent static load model. The proposed algorithm is tested with IEEE 6 bus sample system, which shows the result in each cases by the change of load component factor.

  • PDF

위성망을 이용한 온라인 광역 동기위상 및 전압안정도 감시 시스템 개발에 관한 연구 (A Study on Development of Online Wide Area SynchroPhasor and Voltage Stability Monitoring System using Satellite Network)

  • 권대윤;김태진;윤상현;정광균;오규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.273-274
    • /
    • 2008
  • Recently, the most wide-area blackout in North America, Canada and Europe had shown us indirectly the importance of Wide-Area Power System Protection and had influence on the direction of domestic electric power industry. After reorganization of the electric power industry in 2001, market incentives controls the power generation, transmission and distribution rather than stability of power grid, and moreover it produce bad results like inefficient facility management and too much competition. In addition, we can easily predict the massive loss of social and economic when the wide-area outage occurs by north direction load flow which is a pending problems of domestic power system and in a changed industry likes hi-tech manufacture and information technology industries. This paper introduces the development of infra systems for prevent wide-area blackout in situations of the power system operations.

  • PDF

태양광 어레이의 고장 위치 진단 기법 (Fault Location Diagnosis of Photovoltaic Power Arrays)

  • 이상준;이루다;조현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.81-82
    • /
    • 2015
  • Recently, fault detection and diagnosis techniques have been significantly considered to reduce possible economic loss due to faulty in photovoltaic power systems. This paper presents a new fault location diagnosis method for photovoltaic power systems. The proposed algorithm compares the output voltage generated from a photovoltaic array to the outputs of its neighboring arrays. This concept is realized by obtaining error voltages among all arrays, which are simply defined by deviation between its neighboring arrays. We accomplish a real-time experiment to demonstrate reliability of the proposed fault location diagnosis by using a 60W photovoltaic power system test-bed.

  • PDF

ESS 적용에 따른 원금회수 기간 분석에 관한 연구 (Study on payback period analysis of an ESS application)

  • 채희석;강병욱;홍종석;문종필;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.611-612
    • /
    • 2015
  • Prediction algorithm of the energy storage system in accordance with the load pattern can cause economic loss in case of a failure prediction. In this paper, we compare the electricity charge between industrial power system with ESS - this case's operation is based on Non-prediction operation method. - and without ESS. In addition, we derive the payback period.

  • PDF

보일러 플랜트의 위험상태 예측을 위한 지식표현에 관한 연구 (A Study on the Knowledge Representation for the Recognition of Hazardous Conditions in Boiler Plant)

  • 허보경;안대명;황규석
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.60-67
    • /
    • 1995
  • Ocassionally, many chemical plants experienced unexpected shutdown and suffered serious economic loss caused by boiler accidents due to mis-operations during the start-up or shutdown. A strategy to prevent such accidents is proposed here by using the form of frame for the recognition of all needed conditions, i.e., the states of the boiler, hazardous or dangerous conditions, each level conditions, transition network and heuristic knowledge of human operators. The expert system based on this strategy is considered to be an available method to predict all of the hazardous conditions in boiler plants.

  • PDF

ESD에 의한 반도체소자의 손상특성 (Damage and Failure Characteristics of Semiconductor Devices by ESD)

  • 김두현;김상렬
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.62-68
    • /
    • 2000
  • Static electricity in electronics manufacturing plants causes the economic loss, yet it is one of the least understood and least recognized effects haunting the industry today. Today's challenge in semiconductor devices is to achieve greater functional density pattern and to miniaturize electronic systems of being more fragile by electrostatic discharges(ESD) phenomena. As the use of automatic handling equipment for static-sensitive semiconductor components is rapidly increased, most manufacturers need to be more alert to the problem of ESD. One of the most common causes of electrostatic damage is the direct transfer of electrostatic charge from the human body or a charged material to the static-sensitive devices. To evaluate the ESD hazards by charged human body and devices, in this paper, characteristics of electrostatic attenuation in domestic semiconductor devices is investigated and the voltage to cause electronic component failures is investigated by field-induced charged device model(FCDM) tester. The FCDM simulator provides a fast and inexpensive test that faithfully represents ESD hazards in plants. Also the results obtained in this paper can be used for the prevention of semiconductor failure from ESD hazards.

  • PDF

터빈 수명평가를 위한 전기화학법의 현장적용에 관한 연구 (A Study on the Life Assessment for Turbine Rotor by the In-field Electrochemical Method)

  • 장성호;김진호;송기욱;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.13-18
    • /
    • 2000
  • Nowadays, 60 percent of thermal power plants already have been operated over their own design life. These operations of old power plant over their design life have caused a fracture accident of degradation a loss of economic and human. Therefore, the new life assessment and prediction technology is necessary to improve the safety and reliability of high pressure and high temperature power plant facilities. In this paper, innovative electrochemical test method have been used and results have been compared to the conventional test. Finally, the electrochemical test is applied to the in-field HP turbine and a database is currently in progress for the development of the life assessment standard and procedure.

  • PDF

A Development of Staff Mobility in the System of Strategic Human Resource Management

  • Aigul, Otarbayeva;Samal, Tazhiyeva
    • Asian Journal of Business Environment
    • /
    • 제5권2호
    • /
    • pp.31-36
    • /
    • 2015
  • Purpose - This work aims to study the existing management process and methods of statistical evaluation of personnel mobility management, and propose improvement measures. This is particularly relevant in today's market economy because proper organization of personnel movement affects the availability and effective utilization of human resources in enterprises. Hence, it influences the volume, timely execution of work, equipment efficiency, and consequently the volume of production, its cost, profit, and other economic indicators. Research design, data, and methodology - We investigate the indicators that measure staff mobility, and their dependent consequences. Further, it analyses the factors influencing high staff turnover, which is a main indicator of staff mobility. Results - Measures for staff mobility development and prevention of turnover are proposed. Micom Systems is a sample case that has developed special programs to reduce staff turnover. Conclusions - Staff mobility leads to additional costs, significant loss of working time, and increase in defects. However, the advantages of staff mobility outweigh these negative factors. The role of staff mobility in a market economy cannot be overestimated.

2차원적 음원추적에 관한 연구 II (A Study on 2 -Dimensional Sound Source Tracking System II)

  • 문성배;전승환
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 춘계학술발표회 논문집
    • /
    • pp.156-162
    • /
    • 1998
  • The whistle is a very important information source for the safety navigation under foggy weather. But navigator has no concern about this , because it must be achieved by human hearing sense and considered as a vague signal. If the range and relative bearing of signa source can be detected automatically, it would be very useful system for preventing marine casualties making a lot of economic loss and environment pollution. Before the algorithm of 2-dimensinal sound source tracking system was reported . This paper describes the method that can obtain thetime lag between three signas and the theory of cross-correlation analysis and subtraction method for cauculating the time lag by using the digital signal data sequences. And a series of experiments were carried out for various position of sound source in the range from 200m to 530cm.

  • PDF