• Title/Summary/Keyword: Echocardiography, strain

Search Result 28, Processing Time 0.022 seconds

A Study on the Myocardial of Strain According to Blood Vessels in Echocardiography (심장초음파검사에서 혈관에 따른 심장근육 Strain에 관한 연구)

  • Eun-Kyung Park;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.279-286
    • /
    • 2024
  • Echocardiography is a widely used test to evaluate the contractility of the heart. However, this exam is cannot be said to be objective because the test relies on the examiner's visual judgment. Therefore, although a lot of efforts are being made to quantify the strain through speckle tracking echocardiography (STE), there are some limitations, and studies of conditions to supplement are needed. Through this study, we determine whether the general characteristics of the subjects affect vessel-specific strain and whether changes in various imaging conditions (general, resolution, compression, gain, chroma) affect vessel-specific strain. According to the results of the study, the general conditions obtained during the examination were generally less significant compared to other conversion conditions, and Resolution, Compress, Gain, Chroma, and LAD showed significant correlations under the Compress conditions (p < .05). Therefore, Accurate strain assessment will be made if echocardiography is analyzed using significant conditions for each stenotic vessel

The Usefulness of 4D Echocardiographic Modality for Assessing RV Affection in Uncontrolled Hypertensive Patients

  • Rehab M. Hamdy;Shaimaa A Habib;Layla A Mohamed;Ola H. Abd Elaziz
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.4
    • /
    • pp.279-289
    • /
    • 2022
  • BACKGROUND: In many cardiovascular disorders, the contractile performance of the right ventricle (RV) is the primary determinant of prognosis. For evaluating RV volumes and function, 4 dimensional (4D)-echocardiography has become common. This research used 2D and 4D modalities to assess RV contractile performance in hypertensive patients. METHODS: A total of 150 patients with essential hypertension were enrolled in this study, along with 75 age and sex-matched volunteers. Clinical evaluation and echocardiographic examination (including M-mode, tissue Doppler imaging, and 2D speckle tracking) were conducted on all participants. RV volumes, 4D-ejection fraction (EF), 4D-fractional area change (FAC), 4D-tricuspid annular plane systolic excursion (TAPSE), 4D-septal and free wall (FW) strain were all measured using 4D-echocardiography. RESULTS: Hypertensive patients showed 2D-RV systolic and diastolic dysfunction (including TAPSE, 2D-right ventricular global longitudinal strain, RV-myocardial performance index and average E/EaRV) and 4D-RV impairment (including right ventricular EF, FAC, RV strain and TAPSE, right ventricular end-diastolic volume and right ventricular end-systolic volume) compared to the control group. We verified the prevalence of RV systolic dysfunction in hypertension patients using the following parameters: 1) 15% of them had 2D-TAPSE < 17 mm vs. 40% by 4D-TAPSE; 2) 25% of them had 2D-GLS < 19% vs. 42% by 4D-septal strain and 35% by 4D FW strain; 3) 35% of hypertensive patients had 4D-EF < 45%; and finally; 4) 25% of hypertensive patients had 2D-FAC < 35% compared to 45% by 4D-FAC. CONCLUSIONS: The incidence of RV involvement was greater in 4D than in 2D-modality trans-thoracic echocardiography. We speculated that 4D-echocardiography with 4D-strain imaging would be more beneficial for examining RV morphology and function in hypertensive patients than 2D-echocardiography, since 4D-echocardiography could estimate RV volumes and function without making geometric assumptions.

Assessment of Right Ventricular Function in Pulmonary Hypertension with Multimodality Imaging

  • Seo, Hye Sun;Lee, Heon
    • Journal of Cardiovascular Imaging
    • /
    • v.26 no.4
    • /
    • pp.189-200
    • /
    • 2018
  • Pulmonary hypertension (PH) is defined as resting mean pulmonary artery pressure ${\geq}25mmHg$ and is caused by multiple etiologies including heart, lung or other systemic diseases. Evaluation of right ventricular (RV) function in PH is very important to plan treatment and determine prognosis. However, quantification of volume and function of the RV remains difficult due to complicated RV geometry. A number of imaging tools has been utilized to diagnose PH and assess RV function. Each imaging technique including conventional echocardiography, three-dimensional echocardiography, strain echocardiography, computed tomography and cardiac magnetic resonance imaging has-advantages and limitations and can provide unique information. In this article, we provide a comprehensive review of the utility, advantages and shortcomings of the multimodality imaging used to evaluate patients with PH.

Changes in Cardiac Structure and Function After Kidney Transplantation: A New Perspective Based on Strain Imaging

  • Darae Kim;Minjeong Kim;Jae Berm Park;Juhan Lee;Kyu Ha Huh;Geu-Ru Hong;Jong-Won Ha;Jin-Oh Choi;Chi Young Shim
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.98-104
    • /
    • 2023
  • BACKGROUND: We aimed to investigate left ventricular (LV) global longitudinal strain (GLS) in end-stage renal disease patients and its change after kidney transplantation (KT). METHODS: We retrospectively reviewed patients who underwent KT between 2007 and 2018 at two tertiary centers. We analyzed 488 patients (median age, 53 years; 58% male) who had obtained echocardiography both before and within 3 years after KT. Conventional echocardiography and LV GLS assessed by two-dimensional speckle-tracking echocardiography were comprehensively analyzed. Patients were classified into three groups according to the absolute value of pre-KT LV GLS (|LV GLS|). We compared longitudinal changes of cardiac structure and function according to pre-KT |LV GLS|. RESULTS: Correlation between pre-KT LV EF and |LV GLS| were statistically significant, but the constant was not high (r = 0.292, p < 0.001). |LV GLS| was widely distributed at corresponding LV EF, especially when the LV EF was > 50%. Patients with severely impaired pre-KT |LV GLS| had significantly larger LV dimension, LV mass index, left atrial volume index, and E/e' and lower LV EF, compared to mildly and moderately reduced pre-KT |LV GLS|. After KT, the LV EF, LV mass index, and |LV GLS| were significantly improved in three groups. Patients with severely impaired pre-KT |LV GLS| showed the most prominent improvement of LV EF and |LV GLS| after KT, compared to other groups. CONCLUSIONS: Improvements in LV structure and function after KT were observed in patients throughout the full spectrum of pre-KT |LV GLS|.

Subclinical left ventricular dysfunction in children after hematopoietic stem cell transplantation for severe aplastic anemia: a case control study using speckle tracking echocardiography

  • Kim, Beom Joon;Moon, Kyung Pil;Yoon, Ji-Hong;Lee, Eun-Jung;Lee, Jae Young;Kim, Seong Koo;Lee, Jae Wook;Chung, Nack Gyun;Cho, Bin;Kim, Hack Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.4
    • /
    • pp.190-195
    • /
    • 2016
  • Purpose: Severe aplastic anemia (SAA), a fatal disease, requires multiple transfusion, immunosuppressive therapy, and finally, hematopoietic stem cell transplantation (HSCT) as the definitive treatment. We hypothesized that iron overloading associated with multiple transfusions and HSCT-related complications may adversely affect cardiac function. Left ventricular (LV) function was assessed in children after HSCT for SAA. Methods: Forty-six consecutive patients with a median age of 9.8 years (range, 1.5-18 years), who received HSCT for SAA and who underwent comprehensive echocardiography before and after HSCT, were included in this study. The data of LV functional parameters obtained using conventional echocardiography, tissue Doppler imaging (TDI), and speckle-tracking echocardiography (STE) were collected from pre- and post-HSCT echocardiography. These data were compared to those of 40 age-matched normal controls. Results: In patients, the LV ejection fraction, shortening fraction, end-diastolic dimension, mitral early diastolic E velocity, TDI mitral septal E' velocity, and STE LV longitudinal systolic strain rate (SSR) decreased significantly after HSCT. Compared to normal controls, patients had significantly lower post-HSCT early diastolic E velocity and E/A ratio. On STE, patients had significantly decreased LV deformational parameters including LV longitudinal systolic strain (SS), SSR, and diastolic SR (DSR), and circumferential SS and DSR. Serum ferritin levels showed weak but significant correlations (P<0.05) with LV longitudinal SS and SSR and circumferential SS and DSR. Conclusion: Subclinical LV dysfunction is evident in patients after HSCT for SAA, and was associated with increased iron load. Serial monitoring of cardiac function is mandatory in this population.

Echocardiography Core Laboratory Validation of a Novel Vendor-Independent Web-Based Software for the Assessment of Left Ventricular Global Longitudinal Strain

  • Ernest Spitzer;Benjamin Camacho;Blaz Mrevlje;Hans-Jelle Brandendburg;Claire B. Ren
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.3
    • /
    • pp.135-141
    • /
    • 2023
  • BACKGROUND: Global longitudinal strain (GLS) is an accurate and reproducible parameter of left ventricular (LV) systolic function which has shown meaningful prognostic value. Fast, user-friendly, and accurate tools are required for its widespread implementation. We aim to compare a novel web-based tool with two established algorithms for strain analysis and test its reproducibility. METHODS: Thirty echocardiographic datasets with focused LV acquisitions were analyzed using three different semi-automated endocardial GLS algorithms by two readers. Analyses were repeated by one reader for the purpose of intra-observer variability. CAAS Qardia (Pie Medical Imaging) was compared with 2DCPA and AutoLV (TomTec). RESULTS: Mean GLS values were -15.0 ± 3.5% from Qardia, -15.3 ± 4.0% from 2DCPA, and -15.2 ± 3.8% from AutoLV. Mean GLS between Qardia and 2DCPA were not statistically different (p = 0.359), with a bias of -0.3%, limits of agreement (LOA) of 3.7%, and an intraclass correlation coefficient (ICC) of 0.88. Mean GLS between Qardia and AutoLV were not statistically different (p = 0.637), with a bias of -0.2%, LOA of 3.4%, and an ICC of 0.89. The coefficient of variation (CV) for intra-observer variability was 4.4% for Qardia, 8.4% 2DCPA, and 7.7% AutoLV. The CV for inter-observer variability was 4.5%, 8.1%, and 8.0%, respectively. CONCLUSIONS: In echocardiographic datasets of good image quality analyzed at an independent core laboratory using a standardized annotation method, a novel web-based tool for GLS analysis showed consistent results when compared with two algorithms of an established platform. Moreover, inter- and intra-observer reproducibility results were excellent.