• Title/Summary/Keyword: Echo Output

Search Result 67, Processing Time 0.022 seconds

The effects of the shape of IDT electrode pair on the characteristics of SFIT filter (IDT형의 전극 형태가 SFIT형 필터의 특성에 미치는 영향)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2662-2670
    • /
    • 2009
  • The effect of the reflector type for the SAW filter on the characteristics of the slanted finger IDT filter have been studied by computer simulation. The IDT was evaporated by Aluminum-Copper alloy. The design condition was optimized by the phase shift of the SAWfilter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness are $5,000{\AA}$, and the width and the space of reflector are $3.6{\mu}m$ and $2.0{\mu}m$, respectively. Frequency response of the fabricated SFIT filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 8.2MHz. And we could obtain that the return loss is less then 16dB, the ripple characteristics is probably 4dB and the triple transit echo is less then 18dB after when we have matched impedance.

Resolution Enhancement of an Ultrasonic Sensor System via Multiple Steps of the Transmitter Voltage (다단 송출전압을 이용한 초음파센서 시스템의 분해능 개선)

  • Na, Seung-You;Park, Min-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.298-306
    • /
    • 1997
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensors are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of an object, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensors has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained without the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

Involvement of EMG Variables and Muscle Characteristics in Force Steadiness by Level (수준별 힘 안정성에 대한 EMG 변인 및 근육 특성의 관여)

  • Hyeon Deok Jo;Maeng Kyu Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.336-345
    • /
    • 2023
  • The present study was designed to evaluate changes in neuromuscular properties and the structural and qualitative characteristics of muscles during submaximal isometric contractions at low-to-relatively vigorous target forces and to determine their influence on force steadiness (FS). Thirteen young adult males performed submaximal isometric knee extensions at 10, 20, 50, and 70% of their maximal voluntary isometric contraction using their non-dominant legs. During submaximal contractions, we recorded force, EMG signals from vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF), and ultrasound images from the distal RF (dRF). Force and EMG standard deviation (SD) and coefficient of variation (CV) values were used to measure FS and EMG steadiness, respectively. Muscle thickness (MT), pennation angle (PA), echo intensity (EI), and texture features were calculated from ultrasound images to assess the structural and qualitative characteristics of the muscle. FS, neuromuscular properties, and texture features showed significant differences across different force levels. Additionally, there were significant differences in EMG_CV among the quadriceps at the 50% and 70% force levels. The results of correlation analysis revealed that FS had a significant relationship with EMG_CV in VM, VL, and RF, as well as with the texture features of dRF. This study's findings demonstrate that EMG steadiness and texture features are influenced by the magnitude of the target force and are closely related to FS, indicating their potential contribution to force output control.

Optimization of Array Configuration in Time Reversal Processing (시역전 처리에서 센서 배열 최적화에 관한 연구)

  • Joo, Jae-Hoon;Kim, Jea-Soo;Ji, Yoon-Hee;Chung, Jae-Hak;Kim, Duk-Yung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.411-421
    • /
    • 2010
  • A time-reversal mirror (TRM) is useful in diverse areas, such as reverberation ing, target echo enhancement and underwater communication. In underwater communication, the bit error rate has been improved significantly due to the increased signal-to-noise ratio by spatio-temporal focusing. This paper deals with two issues. First, the optimal number of array elements for a given environment was investigated based on the exploitation of spatial diversity. Second, an algorithm was developed to determine the optimal location of the given number of array elements. The formulation is based on a genetic algorithm maximizing the contrast between the foci and area of interest as an objective function. In addition, the developed algorithm was applied to the matched field processing with ocean experimental data for verification. The sea-going data and simulation showed almost 3 dB improvement in the output power at the foci when the array elements were optimally distributed.

The fabrication and analysis of the SFIT type filter (SPIT형 필터 제작 및 분석)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.699-706
    • /
    • 2010
  • We have studied to obtain the slanted finger interdigital(SFIT) type filter was formed on the Langasite substrate and was evaporated two IDT electrode by Aluminum-Copper alloy respectively. We can fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift conditions of the SPIT type filter. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflectors are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. At the first sample, we have employed that the distance from the hot electrode to the reflectors is $2.4{\mu}m$ distance from the ground electrode to the reflectors is $1.8{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. At the other sample, we have also employed that the distance from the hot electrode to the reflectors and the distance from the ground electrode to the reflectors are $2.4{\mu}m$. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7.3 MHz. And we could obtain that return is less than -20dB, ripple characteristics is probably 3dB and triple transit echo(TTE) is less than -22dB after when we have matched impedance.

The basic experiments for the fabrication of the SPUDT type Inter using the SFIT type filter (SFIT형태를 이용한 SPUDT형 필터제작에 관한 기초실험)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1916-1923
    • /
    • 2007
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and thin we performed computer-simulated by simulator. We cm fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. And we have employed that the distances from the hot electrode to the reflector are $2.0{\mu}m$, $2.4{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7,8MHz. And we could obtain that return loss is less then -18dB, ripple characteristics is probably 3dB and triple transit echo is less then -25dB after when we have matched impedance.

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF