A Study on the Flow Analysis of Triple Eccentric Butterfly Valve with Two-way Pressure (양방향 압력에 작동 가능한 3중 편심 버터플라이 밸브의 유동해석에 관한 연구)

  • RYU, M.R.;PARK, H.J.;KIM, J.H.;LEE, D.H.;LEE, S.B.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2011
  • The triple eccentric butterfly valve has metal sheet and this study about butterfly valve ceiling is an innovative approach. But it is affected by the static pressure as well as cross-current. The damage at the valve on the pipe resulted from the reflux is due to valve leakage. This study is investigated on the triple eccentric disk and it is applied with angle and the static pressure in all cases to develop cross-current triple eccentric butterfly valves. The disc with the diameter of 300A is valve against flow velocity. The entrance pressure by flow characteristics is performed with numerical analysis. As the result, valve torque production is reduced more than the conventional triple eccentric valve and entrance pressure is decreased on the increase of valve open angle. And flow coefficient can be known to be increased.

Comparative Study on Muscle Activity and Torque Value of Quadriceps of Healthy Adults

  • Kim, Min-Kyu;Ji, Hong-Ju;Kong, Yong-Soo;Hwang, Yoon-Tae;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.212-216
    • /
    • 2016
  • Purpose: The current study seeks to identify the relationship between torque values of the quadriceps and muscle activity during isometric and isokinetic exercises. Methods: The subjects of the study included 29 healthy individuals 17 men and 12 women) who took part in isometric and isokinetic exercises that utilized the quadriceps. The isometric exercises were performed three times each at 4 different angles (0, 30, 60, and 90 degrees). For the isokinetic exercises, concentric contraction and eccentric contraction were undertaken three times each at two angular velocities (30 and 60 degrees). Results: The muscle activity of the quadriceps during the isometric exercises showed significant differences at the 30, 60, and 90 degree angles. During the concentric contractions and eccentric contractions, muscle activity at the peak torque of the quadriceps indicated significant differences in vastus medialis, vastus lateralis, and rectus femoris at angular velocities of 30 and 60 degrees. Conclusion: When applied clinically based on the biomechanical analysis of the current study, it is possible to anticipate and selectively strengthen muscles with isometric and isokinetic exercises for not only healthy adults and professional athletes, but also for those who experience limited knee movement for long periods following knee surgeries.

Joint Torque Estimation of Elbow joint using Neural Network Back Propagation Theory (역전파 신경망 이론을 이용한 팔꿈치 관절의 관절토크 추정에 관한 연구)

  • Jang, Hye-Youn;Kim, Wan-Soo;Han, Jung-Soo;Han, Chang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.670-677
    • /
    • 2011
  • This study is to estimate the joint torques without torque sensor using the EMG (Electromyogram) signal of agonist/antagonist muscle with Neural Network Back Propagation Algorithm during the elbow motion. Command Signal can be guessed by EMG signal. But it cannot calculate the joint torque. There are many kinds of field utilizing Back Propagation Learning Method. It is generally used as a virtual sensor estimated physical information in the system functioning through the sensor. In this study applied the algorithm to obtain the virtual senor values estimated joint torque. During various elbow movement (Biceps isometric contraction, Biceps/Triceps Concentric Contraction (isotonic), Biceps/Triceps Concentric Contraction/Eccentric Contraction (isokinetic)), exact joint torque was measured by KINCOM equipment. It is input to the (BP)algorithm with EMG signal simultaneously and have trained in a variety of situations. As a result, Only using the EMG sensor, this study distinguished a variety of elbow motion and verified a virtual torque value which is approximately(about 90%) the same as joint torque measured by KINCOM equipment.

Analysis of the Eccentric Characteristics of the Brushless Motor by the Rotor Structure (회전자 구조에 따른 브러시리스 모터 편심 특성 분석)

  • Son, Byoung-Ook;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.156-163
    • /
    • 2010
  • The brushless motor is getting widely applied to the automotive component with the advantage of the high efficiency, high reliability and etc.. Most of the motor applications require the low vibration and acoustic noise. The cogging torque is the one of the main cause of the noise and vibration. The step-skewed rotor is used to reduce the cogging torque. We analyze the characteristics of the step-skewed rotor and non skewed rotor with the same stator by using 2-dimensional FEM. And then we analyze the characteristics variation according to the rotor eccentricity. The prototype is made and tested. As the results, the step-skewed rotor structure reduce the cogging torque and local radial force but it is more sensitive to rotor eccentricity.

Interaction of internal forces of interior beam-column joints of reinforced concrete frames under seismic action

  • Zhou, Hua;Zhang, Jiangli
    • Structural Engineering and Mechanics
    • /
    • v.52 no.2
    • /
    • pp.427-443
    • /
    • 2014
  • This paper presents detailed analysis of the internal forces of interior beam-column joints of reinforced concrete (RC) frames under seismic action, identifies critical joint sections, proposes consistent definitions of average joint shear stress and average joint shear strain, derives formulas for calculating average joint shear and joint torque, and reports simplified analysis of the effects of joint shear and torque on the flexural strengths of critical joint sections. Numerical results of internal joint forces and flexural strengths of critical joint sections are presented for a pair of concentric and eccentric interior connections extracted from a seismically designed RC frame. The results indicate that effects of joint shear and torque may reduce the column-to-beam flexural strength ratios to below unity and lead to "joint-yielding mechanism" for seismically designed interior connections. The information presented in this paper aims to provide some new insight into the seismic behavior of interior beam-column joints and form a preliminary basis for analyzing the complicated interaction of internal joint forces.

Torque Characteristics Analysis of Harmonic Side Drive Motor by Conformal Mapping (등각사상에 의한 하모닉 모터의 토오크 특성 해석)

  • Yun, Seo-Jin;Lee, Eun-Ung;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.3
    • /
    • pp.104-109
    • /
    • 1999
  • In order to design and predict the performance of the harmonic side drive motor, it is necessary to analyze the torque generated by the structure. In this paper, an analytical model is proposed for design. Conformal mapping is used to model the capacitance and torque of the motor as a function of the rotor angular position with two-dimensional approximation. Then the result of conformal mapping analysis is verified with F.E.M result.

  • PDF

Nonlinear Rotating Flows in Eccentric Cylinders (편심환내의 비선형 회전 유동)

  • Sim, U-Geon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.16-28
    • /
    • 2000
  • The steady rotating flows in eccentric annulus has been studied by a numerical method based on the spectral collocation method. The inner cylinder has a constant angular velocity while the outer on e is stationary. Flow between eccentric cylinders is of considerable technical importance as it occurs in journal bearings. In the present work, the governing equations for laminar flow are expressed as Navier-Stokes equations, including the non-linear convection terms. The solutions were utilized i, estimate the effects of the nonlinear terms on the load acting on the rotating cylinder. Based on the half and the full Sommerfeld methods, the load on the rotating cylinder is evaluated with eccentricity, by integrating the pressure and skin friction around the cylinder. The attitude angle and Sommerfeld reciprocal are calculated from the load. Also, the torque on the rotating inner cylinder was calculated. considering the skin friction. The attitude angle and Sommerfeld reciprocal are decreased with eccentricity. Viscous damping coefficient due to the skin friction becomes larger with decreasing the annular space. It is found the non-linear effects of the convection terms on the flow and the load are important. especially on the attitude angle, for relatively wide annular configurations however, the effects on those are minor for very narrow annular ones.

Difference in Quadriceps and Hamstring torque during exercise with concentric and eccentric contractions according to hip joint anglet (등속성 근력측정 시 Hip Joint Angle에 따른 대퇴사두근과 햄스트링의 단축성과 신장성 근력 차이)

  • Kim, eui-young;Lee, jong-hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2010.05a
    • /
    • pp.161-163
    • /
    • 2010
  • 본 연구의 목적은 등속성 운동수행 및 측정시 hip joint angle에 따라 대퇴근육의 concentric 과 eccentric 근력차이를 분석하기 위하여 등속성 기기 의자 등받이 경사각도를 $100^{\circ}$, $120^{\circ}$, $140^{\circ}$에서 peak torque를 검사하였다. 대상자는 20대 초반의 건강한 남자 대학생 12명을 대상으로, 등속성 기기(Isomed 2000, Germany)를 이용하여 seated position에서 $60^{\circ}/s$ 의 각속도를 사용하여 검사를 수행하였다. 측정순서는 등속성기기 의자 등받이 경사각도 $100^{\circ}$, $120^{\circ}$, $140^{\circ}$ 순으로 2-3일 간격으로 진행하였다. 통계처리 방법은 SPSS 12.0 프로그램을 이용하여 평균과 표준편차를 산출하였으며, 각각의 hip angle에 따른 단축성과 신장성 peak torque 값의 차이는 one-way ANOVA(3RM)을 이용하여 처리하였고, 사후검증은 Tukey를 사용하였으며, 유의수준은 p<.05로 하였다. 연구결과 대퇴사두근의 단축성 근력은 등속성 기기 의자 등받이 경사각 $100^{\circ}$, $120^{\circ}$, $140^{\circ}$사이에 유의한 차이(p=.000)가 나타나 사후 분석결과 $100^{\circ}$$120^{\circ}$ 사이(p<.01) 그리고 $100^{\circ}$$140^{\circ}$ 사이(p<.001)에 유의한 차이를 나타내었으며, 신장성 근력에서는 유의한 차이가 나타나지 않았다. 햄스트링의 단축성 근력은 3종류의 hip angle사이에 유의한 차이(p=.001)가 나타나 사후분석결과 $100^{\circ}$$140^{\circ}$사이(p<.05) 그리고 $120^{\circ}$$140^{\circ}$ 사이(p<.01)에 유의한 차이를 나타내었으며, 그러나 신장성 근력에서는 유의한 차이가 나타지 않았다. 이러한 결과로 미루어 볼 때 등속성 운동수행 및 근력측정 시 hip joint angle 에 따라 대퇴사두근과 햄스트링의 단축성 근력에서 유의한 차이가 나타나 hip joint angle을 고려하여 대퇴근육의 운동및 측정이 이루어져야 할 것으로 사료된다.

  • PDF

Dynamic Behavior Analysis of a Crankshaft-Bearing System in Variable Speed Reciprocating Compressor (가변속 왕복동형 압축기 크랭크축-베어링계의 동적 거동 해석)

  • 김태종
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.426-434
    • /
    • 2001
  • The hermetic reciprocating compressor driven by the BLDC motor rotating with variable speeds, is modelled and analyzed for dynamic characteristics. The governing equations of piston, connecting rod and crank-shaft of the reciprocating compression mechanism and characteristics of driving torque of the motor are obtained. Dynamic behavior of the crankshaft supported on 2 journal bearings is analyzed considering compression load and eccentric unbalance for the 4 rotating speeds of crankshaft. And. reaction forces generated from oil film in the journal bearings are analyzed under transient condition using Reynolds' equation. To take into account the dynamic characteristics depending on the variable rotating speeds, comparison on the dynamic behavior of crank-shaft is made for the 4 operating modes of the compressor. Results show that the magnitude of crankshaft locioperating on the lower rotating speeds is more larger than the higher ones due to reduction of inertia force of the reciprocating piston.

A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path (하악운동 회전량과 과로의 형태에 관한 연구)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF