• Title/Summary/Keyword: Ease of Breathing

Search Result 9, Processing Time 0.028 seconds

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask (작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향)

  • Lee, Jinsil;Cho, Sunhee;Yun, Jungmin;Kim, Min-Sun;Park, Jaekyu;Choe, Jaeho
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.301-310
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

A Study on Breathing Method of Healing as a Health-Oriented Leisure Activity (건강지향적 여가활동으로서 힐링(Healing)호흡법에 대한 고찰)

  • Kim, Ji-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.140-146
    • /
    • 2016
  • This study was conducted to examine the meaning and value of the healing mechanism of breathing as a health-oriented leisure activity to ease mental and physical tension and stress to improve quality of life. The results of this study indicated that leisure activities are increasing in diverse fields. Because modern people have a strong interest in the value of a healthy life, there will be more opportunities to enjoy health-oriented leisure activities, and their health-management efforts will be more fruitful. Additionally, if individuals undergo the process of healing and thereby build the right values about life, it will be possible to set the right direction for "holistic healing" that is needed in social relationships. Moreover, healing breathing can be defined as a leisure activity that aims to promote health through physical and mental healing. Overall, use of health-oriented leisure activities such as the breathing method of healing is expected to increase the essential value of human life and facilitate well-rounded socialization.

Development of Personalized Respiratory Training Device with Real-time Feedback for Respiratory Muscle Strengthening

  • Merve Nur Uygun;Yeong-geol Bae;Yejin Choi;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.251-258
    • /
    • 2023
  • Objective: The practice of breathing exercises involves altering the depth and frequency of respiration. Strengthening respiratory muscles plays a crucial role in maintaining overall health and well-being. The efficiency of the respiratory system affects not only physical activity but also various physiological processes including cardiovascular health, lung function, and cognitive abilities. The study evaluated the reliability of the developed device for inspiratory/expiratory training using pressure sensors and Bluetooth connectivity with a smartphone application. Design: Design & development research Methods: The research methodology involved connecting a custom-made respiratory sensor to an IMT-PEP BIC Breath device. Various pressure conditions were measured, and statistical analyses were performed to assess reliability and consistency. Results showed high Intraclass Coefficient Correlation (ICC) values for both inspiratory and expiratory pressures, indicating strong test-retest reliability. The device was designed for ease of use and wireless monitoring through a smartphone app. Results: This study conducted at expiratory pressure confirmed the proper operation of the IMT/PEP breathing trainer at the specified pressure setting in the product. The pressure sensor demonstrated high test-retest reliability with an ICC value of 0.999 for both expiratory and inspiratory pressure measurements. Conclusions: The developed respiratory training device measured and monitored inspiratory and expiratory pressures, demonstrating its reliability for respiratory training. The system could be utilized to record training frequency and intensity, providing potential benefits for patients requiring respiratory interventions. Further research is needed to assess the full potential of the device in diverse populations and applications.

The effect of contact sport athletes' recognition and wearing of mouthguards on wearing frequency (접촉성 운동선수의 마우스가드에 대한 인식과 착용감이 착용빈도에 미치는 영향)

  • Im, Joong-Jae;Lee, Hye-Eun
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.89-96
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the types of mouthguards athletes who play contact sports use as well as their perceived discomfort of wearing them in order to analyze the relationship with wearing frequency so as acquire basic data for the development of more user-friendly mouthguards. Methods: The participants, who completed a self-report questionnaire, included 70 contact sports athletes, including high school contact (rugby and boxing) sport department affiliated athletes located in the city of Daejeon. Results: Breathing (p<0.01), fitting (p<0.05), ease of wearing (p<0.01), occlusion (p<0.05), and fatigue in muscles (p<0.05) were positively correlated with wearing frequency. Furthermore, the recognition of the mouthguards was not significantly correlated with wearing frequency. Conclusion: To prevent oral and maxillofacial trauma, multi-directional studies are imperative to develop mouthguards, which are comfortable and cost-efficient.

A CASE STUDY OF VARIOUS CLINICAL APPLICATION OF THE RUBBER DAM IN PEDIATRIC DENTISTRY (소아치과 영역에서 러버댐의 다양한 임상적 적용에 대한 증례보고)

  • Yi, Soung-Hyuck;Kim, Jong-Bum;Jang, Ki-Taeg;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.549-555
    • /
    • 1997
  • Usage of the rubber dam has been advocated by countless number of dentists. The advantages of the rubber dam such as the following are well-known 1. Moisture control. 2. Improved field of vision. 3. Ease of approach. 4. Soft tissue retraction and Injury prevention. 5. Prevention of aspiration of materials or instruments. 6. Shortened chair time. 7. Induction of nasal breathing during administration of $N_2O-O_2$ sedation. Recent reports indicate the rubber dam can protect the dental staffs from the infection when treating HBV or HIV positive patients. Also, improved moisture control and freeing of both hands allowed by the rubber dam makes it very useful when bonding orthodontic brackets. This case study presents the various clinical application of the rubber dam on patients visiting SNUDH dept. of pediatric dentistry to emphasize the importance of its use in pediatric dentistry.

  • PDF

Wear Evaluation of Protective Mask according to Internal Volume (보호마스크의 내부 부피에 따른 착용 평가)

  • Eom, Ran-i;Park, Sunhee;Park, Soyoung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.4
    • /
    • pp.626-638
    • /
    • 2020
  • In this study, protective masks were designed in varying internal volume and analyzed in regards to wearing effect. Masks were measured by surface temperature and subjective wear evaluation. Four experimental masks were created with an increasing distance between the mask center line and nose in increments. The distances were set at 0.0 cm (M0), 2.0 cm (M2), 4.0 cm (M4), and 6.0 cm (M6). The area and volume of each experimental mask was measured and both measurements had a positive correlation with the set distances. Among the experimental masks, M2 was the most breathable. The heat between the face and the mask created by exhalation was able to escape from the mask and provided the highest comfort sensation when worn. Conversely, an internal volume that is too large would decrease its comfort because repetitive breathing deforms the appearance of the mask and adversely affects its fit. Therefore, creating and maintaining the optimal internal volume of the M2 mask is important to achieve maximum thermal sensation and ease of wear.

Exploring the Effects of Complex Body Habits Training on Autistic Youth (복합적 몸 습관훈련이 자폐 청년들에게 미치는 효과 탐색)

  • Lee, Ku Yeon;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.9 no.2
    • /
    • pp.62-70
    • /
    • 2020
  • Purpose: According to the Body-EU education program, this study investigates changes after conducting education with ten subjects with autism symptoms (disability level 2~3) 63 times (126 hours) for nearly two years. Methods: Body-EU habit practice, note writings discussion, singing, Bible study, question and communication, class arrangement, etc., a total of 63 times were educated for 2 hours each week. Results: Subjects felt comfortable breathing and improved energy. Other subject's habit of an out-toed gait step and bending back alleviated. One subject made it easier to speak, so if talking with no strength. When breathing, the stuffy nose improved, the eyes became calm, and the hands and feet were warm. Subject felt like my head was cleaned. Heart tightness disappeared. Subject felt at ease as gaining confidence. The subject gained confidence in seeing whoever the other person was. The subject's pronunciation became more sophisticated, with more confidence, and his mouth cramping alleviated. Subjects with right eye movements showed a relatively high concentration in education time. Conclusions: Subjects are educated and trained in making general habits of their body from morning to going to bed. This study was a research program for ordinary people, but it confirmed with autism. Whether it was genetic autism or acquired autism, they could be somewhat relieved.

A Clinical Case Report on Guillain-Barre Syndrome with diplopia (복시(複視)(Diplopia)를 호소하는 Guillain-Barre Syndrome(GBS) 환자 치험 1례 증례보고)

  • Kang, Sung-Wook;Moon, Mi-Hyun;Hong, Suk-Hoon;Hwang, Chung-Yeon;Kang, Jeong-Ran;Park, Joon-Young
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.18 no.3
    • /
    • pp.102-107
    • /
    • 2005
  • Guillain-Barre Syndrome (GBS) is an acute inflammatory demyelinating polyneuropathy. It is disorder in which the body's immune system, attacks parts of the peripheral nervous system. It is characterized by the rapid onset of weakness, paralysis of the legs, arms, breathing muscles and face. But the analysis of CSF and electrical tests on nerve and muscle function can be performed to confirm the diagnosis. Most cases occur shortly after a viral infection. This is a clinical ease report on Cuillain-Barre Syndrome with diplopia. The patient, a 52-year-old man had a weakness in both legs and diplopia. His weakness and diplopia improved after oriental medical treatment, so this is reported as a potential treatment. Objective: This study was designed to evaluate the effects on oriental medicine therapy on Guillain-Barre Syndrome with diplopia. Methods & Result: The Clinical data was analyzed on a patient with Cuillain-Barre Syndrome whose main symptoms were diplopia. The patient was treated by acupuncture and oriental medicine. As a result, symptoms was improved remarkably. Conclusion: The patient showed weakness and diplopia. After acupuncture and oriental medicine treatment, weakness and diplopia was improved in 4weeks after visit to clinic. The study suggests that oriental medicine treatment is effective on Cuillain-Barre Syndrome.

  • PDF

User experience of MV2000-MT (SU:M2)® as a Mechanical Ventilator: A Comparative Clinical Study on Usability, Safety, and Medical Staff Satisfaction

  • Jeon, Soeun;Kim, Hae Kyu;Lee, Dowon;Kim, Hyae Jin;Park, Eun Ji
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.260-267
    • /
    • 2019
  • In the present study, we aimed to demonstrate that MV2000-MT(SU:M2)® (MV, MEK-ICS, Paju, Korea), a domestic ventilator, is not inferior in terms of usability, safety, and medical staff satisfaction as compared to Hamilton G5 (G5, Hamilton Medical AG, Rhäzuns, Switzerland). A total of 39 patients who applied MV (group M) or G5 (group H) were included in the study sample. Usability was evaluated by the following factors: the number of alarm errors, replacement requirement of breathing circuit, replacement requirement of a right-angle connector, and ease of ventilator weaning. For safety evaluation, the number of ventilator replacements due to malfunction of the ventilator was evaluated. Items for medical staff satisfaction survey were as follows: the number of MV and G5 uses, hardware, and software assessment. In the usability evaluation, the replacement requirement of the right-angle connector was lower in Group M than in Group H (mean ± standard deviation, Group M: 7.39 ± 6.72, Group H: 14.19 ± 10.24, p = 0.021); however, the evaluations of other parts were not significantly different between the two groups. The number of ventilator replacements due to a malfunction of the ventilator did not differ between two groups. The number of MV and G5 uses was 3.0 [3.0-4.0] and 10.0 [5.0-10.0] (median [interquartile range], p < 0.001). Overall, the mean medical staff satisfaction score of Hamilton G5 was higher than that of MV2000-MT(SU:M2)®. The usability of MV is comparable to that of G5. However, medical staff satisfaction with Hamilton G5 was higher than that with MV2000-MT(SU:M2)®, and this difference could be due to the difference in the number of uses. In order to improve the penetration rate of the domestic mechanical ventilator, it is necessary to find ways to increase familiarity of medical staff with domestic mechanical ventilators.