• Title/Summary/Keyword: Earthquake force

Search Result 694, Processing Time 0.033 seconds

Non-linear Time History Analyses of a Piloti-type Building Structure (필로티형 건물의 비선형 시간이력해석)

  • Lee, Han-Seon;Ko, Dong-Woo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.169-176
    • /
    • 2005
  • Many RC building structures of multiple uses constructed in Korea have the irregularities of torsion and soft story at bottom stories. A typical irregular building was selected as prototype and shaking table tests were performed to investigate the seismic performance of this building. The objective of this study is to evaluate the correlation between the experimental and analytical responses of this irregular building structure subjected to the earthquake excitation by using OpenSees(Open System for Earthquake Engineering Simulation). The results of analyses simulate well the effect of axial forces on the shear force of column and axial deformation. However, some discrepancy between analytical and experimental results in the distribution of shear forces and overturning deformation were observed.

  • PDF

Parameter Identification and Nonlinear Seismic Analysis of Soil-Structure Interaction System (지반-구조물 상호작용계의 계수추정 및 비선형 지진응답해석)

  • 윤정방
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.265-272
    • /
    • 1997
  • This paper presents the result of an international cooperative research on the post-correlation analysis of forced vibration tests and the prediction of earthquake responses of a large-scale seismic test structure. Through the post-correlation analysis, the properties of the soil layers are revised so that the best correlation in the responses may be obtained compared with the measured force vibration test data. Utilizing the revised soil properties as the initial linear values, the seismic responses are predicted for an earthquake using the equivalent linearlization technique based on the specified strain dependent characteristics of the shear moduli and damping ratios. It has been found that the predicted responses by the equivalent nonlinear procedure are in excellent agreement with the observed responses, which those using the initial properties are fairly off from the measured results.

  • PDF

Seismic Design and Isolation Design for Highway Bridges (교량구조물의 내진설계 및 면진설계(교량 받침을 중심으로))

  • 전규식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.115-122
    • /
    • 1998
  • Earthquake damage civil engineering structures every year in the world and bridges are no exception. Bridge structures have proven to be vulnerable to earthquake, sustaining damage to substructure and foundation and being totally destroys as superstructures collapse from their supporting elements. The poor seismic performance of bridge structures is surprising in view of the substantial advance made in design and construction for vertical load. Recently, bridge spans have been pushed further than before, alignment has become increasingly complex and aesthetic requirement have been become more demanding. To reduce the seismic force and to improve the safety of the advanced bridges, the bridge bearings which are the substructures and foundations and their connections to the superstructure become more important and critical elements. Therefore, the functions about seismic devices to be using as bridge bearing are discussed.

  • PDF

Evaluation of Seismic Force Effects on Skew Bridges (사교에 작용하는 지진하중의 영향 평가)

  • 박형기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.113-119
    • /
    • 1998
  • This study is focused on evaluation of the structural behavior of skewed bridge during earthquake. The variation of natural frequencies and the lateral forces at pier shoes by the skewness and the rotational effect about vertical axis of skewed bridge due to seismic activity are analytically evaluated and identified through case studies. For this purpose, the composite steel girder highway bridges are selected as case study models. The seismic analyses by response spectrum method and time history method are performed for the selected models. It has been recognized that the frequency of longitudinal model increased as the skew angle decreased, while the lateral mode frequency showed the opposite trends. When the skew angle decreased, longitudina seismic forces of the bridge at the pier were increased but decreased in transverse direction. And it also has been found that the skewed bridges of the case study models showed the rotational behavior about vertical axis due to motion of San Fernando earthquake at Pacoima Dam.

  • PDF

A Comparative Study on Aseimatic Performances of Various Base Isolation Systems (여러 가지 기초분리 장치의 내진성능에 관한 비교연구)

  • 박규식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.236-243
    • /
    • 1999
  • A comparative study on aseismatic performances of various base isolation systems for the multi-span continuous bridge is carried out. Several leading base isolation systems the LRB system the RF system the R-FBI system and the EDF system are considered, The displacement of the deck the deformation of the upper ends of the piers the shear force and the bending moment of the lower ends of the piers are obtained by using the accelerograms of the N00W component of El Centro earthquake(1940) and the N90W component of Mexico City earthquake(1985) Nonlinear time-history analysis is carried out. comparisons of the results with the conventional bearing show that the base isolation systems are very effective in reducing the forces transmitted to the superstructures. Furthermore the results also show that the friction-type base isolation systems are less sensitive to unexpected variations in frequency content of the ground acceleration. The R-FBI system shows a good aseismatic performance comparing with other base isolation systems.

  • PDF

Effects of excitation characteristics on the equivalent linear system of a building structure with MR dampers (MR감쇠기가 설치된 구조물의 등가선형 시스템에 대한 가진 특성의 영향)

  • Park, Ji-Hun;Min, Kyung-Won;Moon, Byoung-Wook;Park, Eun-Churn
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.503-510
    • /
    • 2006
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with an MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with an MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed.

  • PDF

Performance Evaluation of Rcentering Smart Damper by Pre-Compression of Polyurethane (폴리우레탄 선압축량에 따른 자동복원 스마트 감쇠장치의 일축반복하중에 대한 성능 평가)

  • Jang, Heemyung
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • As the magnitude and frequency of earthquakes increase in Korea, interest in earthquake damage reduction technology has increased. Therefore, research on vibration damping devices that directly respond to seismic loads is being actively researched. After an earthquake, damage or destruction of the device occurs due to the yield of materials, and thus it takes considerable cost and time for restoration and replacement. To supplement the problems of the existing earthquake damage reduction technology, a study was conducted on the recentering smart damper that can be used continuously after an earthquake. In this study, the recentering smart damper that can be restored to its original shape after load removal was developed using superelastic shape memory alloy, pre-compressed polyurethane. General steel was commonly applied to verify the seismic performance of the superelastic shape memory alloy, and the performance of the smart damper was verified according to the amount of polyurethane pre-compressed

Characteristics on the Vertical Load Capacity Degradation for Impact driven Open-ended Piles During Simulated Earthquake /sinusoidal Shaking, (타격관입 개단말뚝의 동적진동에 의한 압축지지력 저감특성)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.51-64
    • /
    • 1996
  • After the model open-ended pile attached with strain gages was driven into a pressure chamber, in which the saturated microfine sand was contained, the static compression loading test was performed for that pile. Based on the test results, ultimate pile capacity was determined. Then, either simulated earthquake shaking or sinusoidal shaking was applied to the pile with the sustained certain level OP ultimate pile load. Then, pile capacity degradations characteristics during shaking were studied. Pile capacity degradation during two different shakings were greatly different. During the simulated earthquake shaking, capacity degradation depended upon the magnitude of applied load. When the load applied to the pile top was less than 70% of ultimate pile capacidy, pile capacity degradation rate was less than 8%, and pile with the sustained ultimate pile load had the degradation rate of 90%. Also, most of pile capacity degradation was reduced in outer skin friction and degradation rate was about 80% of ultimate pile capacity reduction. During sinusoidal shaking, pile capacity degradation did not depend on the magnitude of applied load. It depended on the amplitude and the frequency , the larger the amplitude and the fewer the frequency was, the higher the degradation rate was. Reduction pattern of unit soil plugging (once depended on the mode of shaking. Unit soil plugging force by the simulated earthquake shaking was reduced in the bottom 3.0 D, of the toe irrespective of the applied load, while reduction of unit soil plugging force by sinusoidal shaking was occurred in the bottom 1.0-3.0D, of the toe. Also, the soil plugging force was reduced more than that during simulated earthquake shaking and degradation rate of the pile capacity depended on the magnitude of the applied load.

  • PDF

Earthquake Analysis of Dam Floodgate Using Calibrated Added Mass (보정된 부가질량을 이용한 댐 수문의 지진해석)

  • Bea, Jung-Ju;Kim, Ho-Seung;Kim, Yong-Gon;Lee, Jee-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.31-40
    • /
    • 2009
  • In this paper, a trial-error based method is presented to calibrate added mass models through numerical iterations minimizing the difference between the measured frequency data and its numerical simulation result for a dam floodgate. Earthquake analysis of the real floodgate for which the on-site hammering vibration test is performed show that the classical Westergaard added mass model gives relatively larger values in the maximum earthquake force and the maximum total displacement than the present added mass model, based on the calibration of on-site measurement data.

Performance Evaluation of Viscoelastic Dampers installed in the Steel Frame Structures Using the shaking table set (진동대 실험을 통한 강골조 구조물에 설치된 점탄성 감쇠기의 성능평가)

  • Kim, Jin-Gu;Seo, Hyun-Su;Kwon, Min-Ho;Lim, Jeong-Hee;Kim, Jin-Sup
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.32-38
    • /
    • 2016
  • It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.