• Title/Summary/Keyword: Earthquake Characteristics

Search Result 1,219, Processing Time 0.031 seconds

Comparison of Wave Model with KMA Buoy Observation Results in the 2002 - 2005 year (기상청 부이 관측결과를 이용한 파랑모델 비교 : 2002년 - 2005년)

  • You, Sung Hyup;Seo, Jang-Won;Chang, You-Soon;Park, Sangwook;Youn, Yong-Hoon
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.279-301
    • /
    • 2006
  • This study analyzed the characteristics of the wind waves near the Korean marginal seas in the 2002 - 2005 year using the third generation wave model, WAVEWATCH - III model. In order to investigate the model performance, model results were compared with the marine meteorological observation results. The 4 years average correlation coefficient between model and observation shows very high value of about 0.77. The model of this study represents very well the characteristics of wind waves near the Korean marginal seas. Simulated monthly sea surface winds and wind waves show the evident spatial variations and this model also simulates very well seasonal characteristics of wind waves in this region.

Inelastic Seismic Behavior of Low-story Standard School Buildings according to Characteristics of Earthquake Loads and Hysteresis Models (지진하중의 특성과 이력모델에 따른 저층 표준학교건물의 비탄성 지진거동)

  • Kim, Jin-Sang;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4294-4301
    • /
    • 2012
  • The inelastic response characteristics of the standard school buildings depending on selection of hysteresis models and variable earthquakes are studied. Three earthquake records of El-centro, Santa-Monica, Taft in accordance with KBC2009 standard and four inelastic hysteresis models such as Degrading tri-linear model, Clough model, Takeda model, and Modified Takeda model are used. The inelastic response characteristics such as story shear force, story drift ratio, story displacement are reviewed. As results, El-centro earthquake shows large response in transverse direction and Santa Monica earthquake shows larger response in longitudinal direction on the contrary. Taft earthquake shows less variation of story drift ratio and story displacement for all hysteresis models and stable response.

Vibration characteristics change of a base-isolated building with semi-active dampers before, during, and after the 2011 Great East Japan earthquake

  • Dan, Maki;Ishizawa, Yuji;Tanaka, Sho;Nakahara, Shuchi;Wakayama, Shizuka;Kohiyama, Masayuki
    • Earthquakes and Structures
    • /
    • v.8 no.4
    • /
    • pp.889-913
    • /
    • 2015
  • Structural vibration characteristics of a semi-active base-isolated building were investigated using seismic observation records including those of the 2011 Great East Japan earthquake (Tohoku earthquake). Three different types of analyses were conducted. First, we investigated the long-term changes in the natural frequencies and damping factors by using an ARX model and confirmed that the natural frequency of the superstructure decreased slightly after the main shock of the Tohoku earthquake. Second, we investigated short-term changes in the natural frequencies and damping factors during the main shock by using the N4SID method and observed different transition characteristics between the first and second modes. In the second mode, in which the superstructure response is most significant, the natural frequency changed depending on the response amplitude. In addition, at the beginning of the ground motion, the identified first natural frequency was high possibly as a result of sliding friction. Third, we compared the natural frequencies and damping factors between the conditions of a properly functional semi-active control system and a nonfunctional system, by using the records of the aftershocks of the Tohoku earthquake. However, we could not detect major differences because the response was probably influenced by sliding friction, which had a more significant effect on damping characteristics than did the semi-active dampers.

Characteristics of Earthquake Responses of an Isolated Containment Building in Nuclear Power Plants According to Natural Frequency of Soil (지반의 고유진동수에 따른 면진 원전 격납건물의 지진응답 특성)

  • Lee, Jin Ho;Kim, Jae Kwan;Hong, Kee Jeung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.245-255
    • /
    • 2013
  • According to natural frequency of soil, characteristics of earthquake responses of an isolated containment building in nuclear power plants are examined. For this, earthquake response analysis of seismically isolated containment buildings in nuclear power plants is carried out by strictly considering soil-structure interactions. The structure and near-field soil are modeled by the finite element method while far-field soil by consistent transmitting boundary. The equation of motion of a soil-structure interaction system under incident seismic wave is derived. The derived equations of motion are solved to carry out earthquake analysis of a seismically isolated soil-structure system. Generally, the results of this analysis show that seismic isolation significantly reduces the responses of the soil-structure system. However, if the natural frequency of the soil is similar to that of the soil-structure system, the responses of the containment buildings in nuclear power plants rather increases due to interactions in the system.

Liquefaction Hazard Map Based on in Pohang Under Based on Earthquake Scenarios (지진시나리오 기반의 포항지역 액상화위험도 작성 연구)

  • Baek, Woo Hyun;Choi, Jae Soon;Ahn, Jae-Kwang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.219-224
    • /
    • 2018
  • The The purpose of this study is to investigate the actual liquefaction occurrence site in Pohang area and to analyze the ground characteristics of Pohang area using the data of the National Geotechnical Information DB Center and to calculate the liquefaction potential index. Based on the results, the distribution of soil classification in Pohang area and the risk of liquefaction under various earthquake accelerations were prepared. As a result of the study, soils in Pohang has the soil characteristics that can cause the site amplification phenomenon. In the analysis through liquefaction hazard maps under earthquake scenarios, it is found that the liquefaction occurred in the area of Heunghae town is more likely to be liquefied than other areas in Pohang. From these results, it is expected that the study on the preparation of liquefaction hazard maps will contribute to the preparation of countermeasures against liquefaction by predicting the possibility in the future.

Pseudo Dynamic Earthquake Response Tests on Steel Frames with Slit Plate Damper (슬릿형 댐퍼를 부착한 철골조 시스템의 가동적 지진응답실험)

  • Lee, Seung-Jae;Park, Jae-Seong;Oh, Sang-Hoon;Ryu, Hong-Sik
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.145-150
    • /
    • 2008
  • The purpose of this study is to propose damper system which is easy to design, which can ensure against risks, and to verify earthquake response characteristics. For this study, the pseudo dynamic earthquake response tests carried out for steel frames with two types of seismic and vibration control device. As a result, in case of using the slit plate damper as a vibration control device proposed by this study, the damper having higher stiffness than main-structure turned to the state of plasticity by little displacement has been proved to be able to absorb earthquake energy.

  • PDF

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

Effect of sequential earthquakes on evaluation of non-linear response of 3D RC MRFs

  • Oggu, Praveen;Gopikrishna, K.
    • Earthquakes and Structures
    • /
    • v.20 no.3
    • /
    • pp.279-293
    • /
    • 2021
  • Most of the existing seismic codes for RC buildings consider only a scenario earthquake for analysis, often characterized by the response spectrum at the specified location. However, any real earthquake event often involves occurrences of multiple earthquakes within a few hours or days, possessing similar or even higher energy than the first earthquake. This critically impairs the rehabilitation measures thereby resulting in the accumulation of structural damages for subsequent earthquakes after the first earthquake. Also, the existing seismic provisions account for the non-linear response of an RC building frame implicitly by specifying a constant response modification factor (R) in a linear elastic design. However, the 'R' specified does not address the changes in structural configurations of RC moment-resisting frames (RC MRFs) viz., building height, number of bays present, bay width, irregularities arising out of mass and stiffness changes, etc. resulting in changed dynamic characteristics of the structural system. Hence, there is an imperative need to assess the seismic performance under sequential earthquake ground motions, considering the adequacy of code-specified 'R' in the representation of dynamic characteristics of RC buildings. Therefore, the present research is focused on the evaluation of the non-linear response of medium-rise 3D RC MRFs with and without vertical irregularities under bi-directional sequential earthquake ground motions using non-linear dynamic analysis. It is evident from the results that collapse probability increases, and 'R' reduces significantly for various RC MRFs subjected to sequential earthquakes, pronouncing the vulnerability and inadequacy of estimation of design base shear by code-specified 'R' under sequential earthquakes.

Structural Effect Evaluation of an Apartment Building Due to the Water Tank under Earthquake Load (지진발생시 아파트 옥탑층 물탱크의 구조적 영향평가)

  • 정은호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.29-40
    • /
    • 1999
  • High-rise building for dwelling has many factors to be considered in structural aspects. In particular, the higher the building, the bigger the lateral loads such as wind and earthquake due to its dynamic characteristics. Unlike the wind load, the earthquake load, even if the shape of the structures are similar, depends on structural characteristics and it is difficult to predict. For an apartment building, the water tank in the penthouse, due to its heavy weight, changes the behavior of a building when the earthquake occurs. The purpose of this study is to determine how the water tank affects the behavior of an apartment building when earthquake occurs. Dynamic analysis was accomplished on two cases - 1) water tank is considered 2) water tank is not considered - to understand how it affects the behavior of a high-rise apartment building. Structural design was accomplished to understand how the water tank and the peak acceleration affects each structural member. The effect of the water tank on the response of structure was large. Elsewhere the water tank has no effect on the design of a strutural member. However some structural members were affected when the peak acceleration of an earthquake is 0.4g.

  • PDF

Earthquake Response Analysis at Port Island during the 1995 Hyogoken-nanbu Earthquake(Japan) (일본 한신 대지진에 있어서의 포트 아일랜드의 지진응답해석)

  • 황성춘
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.477-484
    • /
    • 2000
  • Earthquake response analyses are conducted for the investigation of the ground shaking during the 1995 Hyogoken-nambu earthquake. Port Island a man made island with about 8{{{{ KAPPA m^2 }} area is chosen for this purpose Because earthquake measurement with vertical array was conducted there. Strain dependent characteristics of soil can be modeled well into Hardin-Drnevich Model. Four analyses are conducted : total stress analysis by equivalent linear method non-linear method. and two effective stress analyses. All analyses except equivalent linear analysis show fairy good agreement with observed record mainly because the non-linear behavior of Holocene clay layer has predominant effect on the behavior of fill, However detailed investigation show that effective stress analyses give much better prediction than total stress analyses.

  • PDF