• 제목/요약/키워드: Earthing system

검색결과 47건 처리시간 0.019초

방전전극을 사용한 접지시스템에 관한 연구 (A Study on the Earthing System of Using Discharge Electrodes)

  • 설동화;김명생;김창봉;우제욱
    • 정보통신설비학회논문지
    • /
    • 제8권2호
    • /
    • pp.84-89
    • /
    • 2009
  • This paper has purpose of designing the earthing system installed on the ground without laying under the ground. As a solution for green IT environment to solve the existing earthing system, the third generation earthing machine was designed by using discharge electrodes, catalyzer, and hot wires. As a result of comparison, it found that the third generation earthing system suggested in this research had more increased discharge currents by 31[A] and the speed 25 times faster than the second generation earthing system. The suggested earthing system is allowed to be installed on the ground and solve construction costs, time, area, and environment pollution, which are problems in the existing earthing system. In addition, as the earthing technique has recently developed, the earthing system is classified by generation based on capacity.

  • PDF

국제표준에 따른 건축전기설비의 접지시스템 설계순서 (The Design Flowchart of Earthing System for Building Electrical Installations in Accordance with International Standards)

  • 이주철;염진근;정승현;변철균;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.113-120
    • /
    • 2014
  • In this paper, designing of an earthing system in accordance with international standards with regard to 22.9kV-y multi-grounded neutral system is discussed and confirmed that the consumer's earthing system can be a part of a global earthing system by interconnecting its earthing system with the neutral conductor of 22.9kV-y multi-grounded system. Further, it is proposed that some modification of the earthing system design flowchart given in the international standards are necessary when considering the equipotential bonding, lightning protection, and telecommunications facilities as well as the basic safety requirements.

접지시스템에 관한 연구 (A Study on the Earthing System)

  • 설동화;김명생;김창봉;우제욱
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.375-378
    • /
    • 2009
  • This paper will arrange and classify the earthing system by the latest developed technique tendency, and suggest how to solve the problem of a current earthing system. The 3rd generation earthing system is environment-friendly and designed to use discharge electrodes, catalysts and heat rays. A discharge current has increased by 31 [A] in the 3rd generation of earthing system compared to the 2nd one and it is 25 times faster. This system is not buried under but built on the ground. It solves the problems that the current system has; expenses, time, area and pollutions followed by the construction.

  • PDF

대지에 매설할 필요가 없는 접지시스템에 관한 연구 (A study on an earthing system without ground connection)

  • 설동화;김창봉;우제욱
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF

콘크리트에 매입된 기초접지극의 크기 및 설치방법에 관한 고찰 (A Consideration of Volume and Installation Method of Concrete-Embedded Foundation Earthed an Electrode)

  • 이주철;이영철;김재철
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.82-88
    • /
    • 2013
  • IEC standards do not require to limit the earthing resistance of the concrete-embedded foundation earthing electrode which is installed to a specific value. However, in Korea the value of $5{\Omega}$ and below applies to the earthing resistance for a domestic customer whose receiving voltage is 22.9kV. This paper calculates the minimum area and volume of the concrete-embedded foundation earthing electrode in order to obtain a specific value of the earthing resistance when the electrode of the building's lightning protection system and that of its power system are interconnected. It also suggested the most appropriate method of installing the foundation earthing electrode, taking the electric characteristics of concrete into account.

철도 지하구간에 대한 효율적인 접지방안에 대한 연구 (Study on the effective earthing method in underground section of railways)

  • 김양수;김재문
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.767-775
    • /
    • 2005
  • Power Supply System for electric railways is diversified with technical development and is required high technologies. especially, recently there is required many research and development for earthing to ensure safety of people and protection of installations. Generally, leakage resistance is high between rail and ground at tunnel section of subway. because of short circuit of feeding line, earthing interference by transient overvoltage between signals and communication system, and insulation failure, it can damage to human and equipments To minimize these obstacles, earthing equipment is installed at underground section of railway, but it brings about problems in accordance with operate each earthing system to be not enough required protection provisions for electrified railways. This paper proposes effective earthing method to be concerned about installation cost and maintenance. The validity of the proposed earth method is verified by simulation results at underground section of railways.

  • PDF

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System)

  • 김정철;이규선;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

접지품질 개선을 위한 접지저항 최적화 및 접지충진제의 전기적 특성 연구 (Optimization of the Earthing Resistance and Research on the Electrical Characteristics of New Catalyst for the Quality Earthing)

  • 박철근;안성준;우제욱;안수준;유용정;안승준
    • 한국산학기술학회논문지
    • /
    • 제7권6호
    • /
    • pp.1078-1085
    • /
    • 2006
  • 시설물이나 장비로 surge wave가 유입되는 것을 방지하기 위해서는 접지시스템의 접지저항을 수 $\Omega$ 정도로 낮추어야 하지만 시공비를 낮추기 위하여 적절한 접지저항 값을 결정하는 것이 중요한 문제이다. 본 연구에서는 접지저항 simulator를 이용하여 최적화된 경제적 접지저항(임피던스) 값을 설정하였으며 수용성 알칼리족 원소와 활성탄소를 주성분으로 하는 새로운 접지충진제를 개발하여 접지품질을 개선하기 위한 전기적 특성을 평가하였다.

  • PDF

지중송전케이블의 불완전 순환전류에 관한 연구 (A Study on unperfected circuiting current of undergrounded cable)

  • 이관우;이용성;김보경;박복기;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.3-6
    • /
    • 2004
  • In this paper, we studied on permissible current of unperfected earthing for cross-bond system. The factors of unperfected earth were jacket damage, cross-bonding mistake, arrestor damage, effect of other circuit but we only studied permissible current of arrestor or jacket damage. In the result, we earned that permissible current of normal 154[[kV]] CV $1C{\times}400SQMM$ cable is 760[A] but current of unperfected earthing cable is 76[A], unperfected earthing confirmed that accident of underground cable could occur. So, we could confirmed that Earthing resistance of unperfected earthing need to limit.

  • PDF

전기철도 시스템에서의 터널, 교량구간 접지방안 연구 (A Study on the Electric Railroad Grounding System of Tunnels and Bridges)

  • 윤응규;오광해;오기봉
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.559-565
    • /
    • 2002
  • This paper presents a standard grounding scheme for bridge and tunnel areas where earthing wires cannot be easily buried. Specially, a new grounding method in which structure grounding devices are used shows good grounding effects like the earthing-wire grounding scheme. The proposed method can be a measure for equal potential in case earthing cables are disconnected.