• Title/Summary/Keyword: Earth fault

Search Result 425, Processing Time 0.03 seconds

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Development of Digital Distance Relay Algorithm Using Fuzzy Inference System on Underground Power Cable Systems (퍼지추론 시스템을 이용한 지중송전계통 보호용 디지털 거리계전 알고리즘 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.502-503
    • /
    • 2006
  • If the fault occurs on the underground Power cable system, the fault current on the sheath has the influence on all sections because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) at joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current. Then the impedance between relaying point and fault point is Increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting of the underground power cable systems was developed. It effectively advance the errors using ACI(Advanced Computing Intelligence) technique. In this algorithm, the optimization was performed by fuzzy inference system and genetic algorithm.

  • PDF

Sediment-hosted gold mineralization of the Kyaukpahto mine, Kawlin Township, Myanmar

  • Swe, Ye-Myint;Min, A-Ung;Lee, In-Sung
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.315-315
    • /
    • 2003
  • Gold mineralization at Kyaukpahto occurs as stockworks/disseminations and locally as breccia zones in silicified sandstones of Lower to Middle Eocene Male Formation of Myanmar. The mineralization is spatially related with NNE -trending fracture zones_probably tensional open fractures caused by the right-lateral Sagaing fault system. Intensive silicification, sericitization, argillic alteration, sulfidation, and decalcification are recognized in the Kyaukpahto mine area. (omitted)

  • PDF

A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems (배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin;Lee, Kang-Soo;Choi, Sun-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • A safe grounding design is used for providing means to carry electric currents into the earth under fault conditions without exceeding any operating limits and for assuring that a person in the vicinity of grounded facilities is not exposed to danger of critical electrical shock. Transformer neutral point grounding is for the purpose of controlling the voltage to earth within tolerable limits under a line-to-ground fault. Transformer frame grounding is for the purpose of minimizing the hazardous potential within safety criteria appearing at the faulted equipment. ills paper deeply investigates the grounding resistance effects of distribution power transformers by analysing the neutral to eatth voltages and touch voltages when the fault occurs.

Friction-dependent Slip Behavior of Imgok Fault under the Present-day Stress Field (현생 응력하에서 단층 마찰계수에 따른 임곡단층의 거동 가능성 해석)

  • Na, Hyun-Woo;Chang, Chandong;Chang, Chun-Joong
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2013
  • We carried out geometrical, kinematic, and geomechanical analyses on a lineament (the Imgok fault) near Gangneung, observed in ASTER images and aerial photographs, and field surveys. Earthquake focal mechanism solutions, used to estimate the present-day stress state, revealed that the direction of maximum compression is approximately N$70^{\circ}$E and that the stress condition is in favor of either strike-slip or reverse movement on the fault. The strike of the fault is not ideal for slip under the present-day stress field and thus the fault has a low slip tendency. However, the fault may be able to slip if the frictional coefficient (${\mu}$), representing the resistance of the fault to slip, is sufficiently low (e.g., ${\mu}$ < 0.25).

Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage (직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단)

  • Park, Je-Wook;Baek, Seong-Won;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.457-465
    • /
    • 2011
  • The fault analysis and detecting algorithm for a 3 phase diode rectifier is proposed. The 3 phase dioderectifier is used for the AC power rectifier of the PWM inverter. The input power or diode faults cause theripples of the DC voltage, degradation of the control performance and life shortening of the DC link capacitor.In this paper, the ripple of the DC voltage is mathematically analyzed for the earth fault of input power andopen circuit fault of the diode, respectively. The fault detection and type of fault can be obtained by comparingthe average DC voltage and the instant DC voltage which is sampled with 6 times of grid frequency. Theproposed method can be easily applicable and doesn't require additional circuit. The experimental and simulationresults are presented to verify the validity of the proposed method.

A Study on the Lineament Analysis Along Southwestern Boundary of Okcheon Zone Using the Remote Sensing and DEM Data (원격탐사자료와 수치표고모형을 이용한 옥천대 남서경계부의 선구조 분석 연구)

  • Kim, Won Kyun;Lee, Youn Soo;Won, Joong-Sun;Min, Kyung Duck;Lee, Younghoon
    • Economic and Environmental Geology
    • /
    • v.30 no.5
    • /
    • pp.459-467
    • /
    • 1997
  • In order to examine the primary trends and characteristics of geological lineaments along the southwestern boundary of Okcheon zone, we carried out the analysis of geological lineament trends over six selected sub-areas using Landsat-5 TM images and digital elevation model. The trends of lineaments is determined by a minimum variance method, and the resulting geological lineament map can be obtained through generalized Hough transform. We have corrected look direction biases reduces the interpretability of remotely sensed image. An approach of histogram modification is also adopted to extract drainage pattern specifically in alluvial plains. The lineament extracting method adopted in this study is very effective to analyze geological lineaments, and that helps estimate geological trends associated various with the tectonic events. In six sub-areas, the general trends of lineaments are characterized NW, NNW, NS-NNE, and NE directions. NW trends in Cretaceous volcanic rocks and Jurassic granite areas may represent tension joints that developed by rejuvenated end of the Early Cretaceous left-lateral strike-slip motion along the Honam Shear Zone, while NE and NS-NNE trends correspond to fault directions which are parallel to the above Shear Zone. NE and NW trends in Granitic Gneiss are parallel to the direction of schitosity, and NS-NNE and NE trends are interpreted the lineation by compressive force which acted by right-lateral strike-slip fault from late Triassic to Jurassic. And in foliated Granite, NE and NNE trends are coincided with directions of ductile foliation and Honam Shear Zone, and NW-NNW trends may be interpreted direction of another compressional foliation (Triassic to Early Jurassic) or end of the Early Cretaceous tensional joints. We interpreted NS-NNE direction lineation is related with the rejuvenated Chugaryung Fault System.

  • PDF

Analysis of Earth Continuity Conductor Installation Effect According to Fault Section in Combined Transmission Systems (혼합송전계통에서 고장구간에 따른 병행지선 설치효과 검토)

  • Kang, Ji-Won;Jung, Chae-Kyun;Park, Hung-Sok;Jang, Tai-In;Yoon, Hyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.110-112
    • /
    • 2008
  • This paper describes the effects of earth continuity conductor for reducing the level of induced sheath overvoltage at the single point bonded section of combined transmission systems. Firstly, 3 kinds of fault section are considered, and also faulty phases and the distance between phase conductor and earth continuity conductor are changed for the various analysis.

  • PDF

A Study on the Unification of The Grounding System of SeoulMetro due to Ageing (서울메트로 접지시스템의 경년변화에 따른 개선 접지 기준)

  • Min Byung-Hoon;Kim Gyunl-Sig;Chung Young-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.394-400
    • /
    • 2006
  • Since Seoulmetro built the first line of electric railway at seoul 1974, the passengers of railway have been increased rapidly, and electric railway requires more electric power for the greater capacity of transport. It is important that we prevent the accidents related with the subway, because all systems of subway are constructed in artificial underground structure. Since the previous versions of the earth system were built to meet the old standards of the electric facility for the lightning, some accidents related with the DC earth fault are causing secondary damages to the electric equipments. So, the old grounding system must be improved, and new standards of grounding system are required. We compare the grounding systems of the domestic railway corporations and the accidents that are related with the grounding systems. And we give ideas to improve the grounding systems and present standards which are suitable to electric railway.

Geochemistry for the Serpentinites of the Igneous and Metamorphic Origins

  • Song, Suck-Hwan;Park, Seong-Gyu;Oh, Chang-Whan;Seo, Ji-Eun
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.196-197
    • /
    • 2003
  • Several masses of the alpine type ultramafic rocks are found within the Precambrian Kyeonggi gneiss complex, western part of Chungnam province. They occur as discontinuous isolated lenticular bodies along the fault line(NNE direction), dominant tectonic directions of Kyeonggi gneiss complex. The ultramafic rocks occur as fault contacts with the adjacent Precambrian metamorphic and metasedimentary rocks. (omitted)

  • PDF