• 제목/요약/키워드: Earth Leakage Circuit Breaker

검색결과 45건 처리시간 0.024초

전기적 노이즈에 의한 누전차단기의 오동작에 관한 실험적 연구 (An Empirical Study on Malfunction of the Earth Leakage Circuit Breaker)

  • 김태만;권용준;기도형
    • 한국안전학회지
    • /
    • 제17권1호
    • /
    • pp.45-53
    • /
    • 2002
  • The purpose of this study was to investigate effect of electrical noise on malfunction of the earth leakage circuit breaker. A three-way experiment for studying its malfunction was conducted, in which electrical products such as radio, alternating current are welder and cellular phone, distance from the earth leakage breaker to electrical products, and whether or not the earth leakage breaker is contained is contained in the steel box were employed as experimental variables. Eleven earth leakage breakers frequently used in real situations were tested in each experimental treatment. The electrical products were used for generating electrical noise that is known to be able to cause malfunction of the earth leakage breaker. The results showed that except a case for one of the 11 earth leakage breakers when the radio made by M company was located 30 cm ahead of the breaker, malfunction did not occur in any other experimental treatment. Consequently, it is suggested that the breaker should be normally used for preventing electricity-related accidents without fear of its malfunction in industrial sites.

적분기를 이용한 저항성 누전전류 작동방식 누전차단기 개발 (Development of an Earth Leakage Breaker Operating by Resistive Leakage Current using a Resetable Integrator)

  • 함승진;한송엽;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.917-918
    • /
    • 2007
  • The former earth leakage breaker is operating by total leakage current which is the vector-sum of resistive leakage current and capacitive leakage current. However, the electric disaster like the electric shock and fire is caused mainly by resistive leakage current. Therefore, the earth leakage breaker is ideal when it is operating by resistive leakage current. In this paper, the theory for finding the component of resistive leakage current from total leakage current is suggested and it is embodied to actual circuit. The resistive leakage current can be found by integrating the total leakage current during half cycle of line voltage. Thus, we can simply find resistive leakage current by using OP-AMP integrators, and we can confirm that the resistive leakage current is computed exactly from total leakage current obtained by resistive leakage current and capacitive leakage current. The results that the earth leakage breaker is operating within regular interrupt time are verified when the former earth leakage breaker's controller circuit is replaced by the proposed controller circuit.

  • PDF

화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구 (Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function)

  • 고완수;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.43-48
    • /
    • 2020
  • 본 연구에서는 누전경보 기능이 내장된 누전경보차단기(JER-E2S, ETECKOREA Co., Korea)를 개발하고, 그 특성을 분석하였다. 개발된 누전경보차단기는 단상 220 V 전용으로 정격전류는 32 A, 20 A, 20 A(화장실용), 16 A 등이다. JER-E2S는 기존 누전차단기(ELB)의 특성을 모두 만족하고 있으며, 13 ± 2 mA의 저항성누설전류(Igr)인 화재전류가 전선로에 흐르면 실시간 검출하여 LED 램프로 위험 상태를 점멸할 수 있는 제품이다. 개발된 누전경보차단기는 LED 램프 및 통신기기 등에서 필연적으로 발생되는 용량성누설전류(Igc)에 대한 내성이 있어서 안정적인 전기 공급이 가능하다. 또한, 누전경보차단기는 순간지락 정전보호 기능이 있어서 작은 물방울 및 나뭇잎 등의 순간지락에 따른 차단기의 오동작 없이 전원 공급이 가능하다. 그리고 개발된 누전경보차단기의 대기전력은 0.1 W 이하로 기존 ELB에 비해 절전 성능이 3~8배 우수한 특성을 나타냈으며, 일반 120 ㎡의 아파트 1 세대에 10개 정도의 누전경보차단기가 설치되었을 때 1 개월에 2~5 kWh의 전기를 절감할 수 있다. 개발된 누전경보차단기는 기존 누전차단기의 특성을 만족할 뿐만 아니라 전기화재 예방기능 및 오동작 방지기능이 있어서 전원 품질이 우수하고, 전기화재 예방에 혁신적으로 기여할 수 있는 제품이다.

가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구 (A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test)

  • 강신동;김재호
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

저항성 누전전류에 의하여 동작하는 새로운 누전차단기 (The New Residual Current Protective Devices Operating by Resistive Leakage Current)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발 (Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구 (The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker)

  • 류행수;김명석;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF

전기자동차 충전기의 누전차단기 감도 전류 Trip 방지를 위한 Joule Heating 시뮬레이션 방안연구 (A Study on Joule Heating Simulation Method to Prevent Sensitivity Current Trip of Electric Vehicle Charger)

  • 이병국;어익수
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.150-159
    • /
    • 2021
  • 본 논문에서는 충전 시 발생하는 누전차단기 Trip으로 충전 중단에 의한 전기자동차 사용자의 불편함을 방지하기 위한 것이다. 현장 사례연구로 충전기 고장(failure) 유형, 차종별 누설전류 측정실험, 누전차단기 동작 실험 시 여름철 충전기 내부 온도가 60 ℃이상까지 상승하여 누전차단기가 정격 감도 전류의 80%에서 Trip으로 충전 중단됨을 확인하였다. Joule Heating 모델링을 통하여 32A 전류를 초기 시간 t=0 (s)의 기준온도 30℃에서 통전하여 t=3000 (s)경과 후에는 누전차단기 충전부 주위에서 발열이 32.4℃까지 증가함을 시뮬레이션으로 확인하였으며, 통계 검증 tool을 활용하여 온도 및 시간(s) 요인이 발생 열량에 상관관계 0.97로 검증되었다. 본 논문의 연구 실험 결과는 충전기 기구 물 개발 시 충전케이스의 재질, 내부 배선의 배치, 유전 매질에 따른 Joule Heating 시뮬레이션 수행으로 여름철 충전기 내부 온도 상승에 의한 누전차단기 감도 전류 Trip을 방지할 수 있음을 알 수 있었다.

병렬아크에 대한 누전차단기의 트립특성 분석 (Analysis of Tripping Characteristics of Earth Leakage Circuit Breakers against Parallel Arcing)

  • 김일권;박대원;최수연;조영진;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.478-479
    • /
    • 2007
  • Many electrical fires are occurred by leakage currents and sparks generated by a short circuit. Earth leakage circuit breakers (ELCBs) should be tripped at the moment of the faults mentioned above. In this paper, we described the tripping characteristics of ELCBs against parallel arcing faults. A diesel engine generator with the capacity of 375 kVA source was adopted to provide enough large current when a parallel arcing occurred. The experimental results showed that most ELCBs we experimented were not tripped against short-duration pulse currents produced by parallel arcing because the ELCBs are designed to be tripped by a large current with long duration similar to power frequency.

  • PDF