• Title/Summary/Keyword: Earth Heat

Search Result 428, Processing Time 0.023 seconds

Phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) Superconductor during Continuous Cooling and Isothermal Heat Treatment (등온열처리와 냉각에 따른 $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) 초전도체의 상변화)

  • O, Yong-Taek;Shin, Dong-Chan;Han, Young-Hee;Sung, Tae-Hyun;Jeong, Nyeon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.42-45
    • /
    • 2003
  • The phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) was investigated using isothermal heat-treatment and continuous cooling in air. During continuous cooling, the $REBa_2Cu_3O_{7-x}$ (RE=123) superconducting phase with well-distributed $REBa_2Cu_3O_{7-x}$ (RE-211) was obtainde at a cooling rate of $0.001^{\circ}C$/s. Single phase RE-123 (Nd, Gd, Dy) was stable at $1050^{\circ}C$, $1050^{\circ}C$, and $950^{\circ}C$ during isothermal heat-treatment, respectively. Above these temperatures the RE-211 phase existed within the RE-123 grains. The RE-123, RE-211, $BaCu_2Od_2$, and CuO phases coexisted at $50^{\circ}C$ below the partial melting temperature for each respective rare-earth RE-123.

  • PDF

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

A Study of Seepage in Earth Structure of Zone Types (이형제체의 침투에 관한 연구)

  • Shin, Bang Woong;Lee, Bong Jik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.135-144
    • /
    • 1991
  • The phreatic surface in earth embankment of zone types are investigated in this thesis. Also the shape of phreatic surface are analyzed according to rising velocity and slope angle. In order to verify the validity of experimental results, the results are compared with theoretical result. From this comparison, the shape of phreatic surface in multi-layer is predicted by heat transfer equation.

  • PDF

Characteristics of Mesoscale Circulation with the Detailed Building Distribution in Busan Metropolitan Area (부산지역 빌딩 분포 상세화에 따른 중규모 순환 특성)

  • Son, Jeong-Ock;Lee, Hwa-Woon;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.2
    • /
    • pp.203-215
    • /
    • 2012
  • In order to clarify the impacts of thermal difference in atmospheric boundary layer due to the different sophistication of building information in Busan metropolitan areas, several numerical simulations were carried out. ACM (Albedo Calculation Model) and WRF (Weather Research and Forecasting) was applied for estimating albedo and meteorological elements in urban area, respectively. In comparison with coarse aggregated and small buildings, diurnal variation of albedo is highly frequent and its total value tend to be smaller in densely aggregated and tall buildings. Estimated TKE and sensible heat flux with sophisticatedly urban building parameterization is more resonable and valid values are mainly induced by urban building sophistication. The simulation results suggest that decreased albedo and increased roughness due to skyscraper plays an important role in the result of thermal change in atmospheric boundary layer.

Micro-structural defects in ruby samples from Mong Hsu, Myanmar

  • Maneeratanasarn, P.;Wathanakul, P.;Kim, Y.C.;Choi, H.M.;Bang, S.Y.;Choi, B.G.;Shim, K.B.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.90-94
    • /
    • 2009
  • Mong Hsu rubies from Myanmar were heat treated in oxidizing(oxygen) atmosphere at $1650^{\circ}C$ for 1 hour. The investigations of the micro-structural defects in the samples before and after heat treatment have been carried out by the variety of analysis techniques of FTIR, UV-VIS-NIR and SEM-EDS. It was found that after heat treatment the dark blue cores region were disappeared and turned to orange red color with the presence of the dense cloudy brownish colored tiny particles in and near former blue zoning. As-received ruby samples only revealed the presence of FTIR absorption peaks of diaspore, boehmite and O-H stretching, at 1986, 2115 and $3078/3319\;cm^{-1}$ respectively. The UV-VIS-NIR absorption of as-received and heat treated ruby samples similarly showed peaks at 405, 554 and 693 nm associated with $Cr^{3+}$, but for the same samples, the absorption peak of heat-treated ruby samples at 693 nm was somewhat stronger than that of the untreated ruby samples. Especially the presence of $Cr^{3+}$ peaks at 659 and 675 nm was found obviously in as-received ruby samples only. The SEM-EDS investigation disclosed the micro-porous defect structures commonly related to the core regions of the untreated ruby samples, which after heat treatment in an oxidizing environment those defect features have been dissolved into the host phase resulting in the lightening or disappearance of the dark coloration of ruby core.

Heat Treatment Condition for Preparing $Nd_{1+x}Ba_{2-x}Cu_{3}O_{7-\delta}$ Superconductors

  • Fan Zhan guo;wha, Soh-Dea;zhan, Si-Ping;Li Yingmel;Lim Byongjae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.624-627
    • /
    • 2001
  • Two kinds of Nd$_{1+x}$Ba$_{2-x}$Cu$_3$O$_{7-{\delta}}$, the sintering samples and zone melting samples, were heat treated under pure Ar at 95$0^{\circ}C$. The substitution of Nd ion for Ba ion in the Nd$_{1+x}$Ba$_{2-x}$Cu$_3$O$_{7-{\delta}}$ before and after the heat treatment were investigated by XRD. In order to know the effects of the heat treatment, the T$_{c}$ and J$_{c}$ of samples with the heat treatment and those without the heat treatment by Ar were comparatively studied. The results show that the substitution of Nd for Ba decreased, T$_{c}$, and J$_{c}$ increased after the treatment under Ar at 95$0^{\circ}C$. The Nd$_{1+x}$Ba$_{2-x}$Cu$_3$O$_{7-{\delta}}$ samples were oxygenated under pure oxygen at 30$0^{\circ}C$. From the XRD pattern it was found that the sample with x< 0.4 could transfer from tetragonal phase to orthorhombic phase after the oxygenation, but the sample with x>0.4 could not make the phase transition even after a long time oxygenation.ion even after a long time oxygenation.ation.n.ation.ation.

  • PDF

INTRODUCTION OF J-OFURO LATENT HEAT FLUX VERSION 2

  • Kubota, Masahisa;Hiroyuki, Tomita;iwasaki, Shinsuke;Hihara, Tsutomu;Kawatsura, Ayako
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.306-309
    • /
    • 2007
  • Japanese Ocean Flux Data Sets with Use of Remote Sensing Observations (J-OFURO) includes global ocean surface heat flux data derived from satellite data and are used in many studies related to air-sea interaction. Recently latent heat flux data version 2 was constructed in J-OFURO. In version 2 many points are improved compared with version 1. A bulk algorithm used for estimation of latent heat flux is changed from Kondo (1975) to COASRE 3.0(Fairall et al., 2005). In version 1 we used NCEP reanalysis data (Reynolds and Smith, 1994) as SST data. However, the temporal resolution of the data is weekly and considerably low. Recently there are many kinds of global SST data because we can obtain SST data using a microwave radiometer sensor such as TRMM/MI and Aqua/AMSR-E. Therefore, we compared many SST products and determined to use Merged satellite and in situ data Global Daily (MGD) SST provided by Japan Meteorological Agency. Since we use wind speed and specific humidity data derived from one DMSP/SSMI sensor in J-OFURO, we obtain two data at most one day. Therefore, there may be large sampling errors for the daily-mean value. In order to escape this problem, multi-satellite data are used in version 2. As a result we could improve temporal resolution from 3-days mean value in version 1 to daily-mean value in version 2. Also we used an Optimum Interpolation method to estimate wind speed and specific humidity data instead of a simple mean method. Finally the data period is extended to 1989-2004. In this presentation we will introduce latent heat flux data version 2 in J-OFURO and comparison results with other surface latent heat flux data such as GSSTF2 and HOAPS etc. Moreover, we will present validation results by using buoy data.

  • PDF

The Analysis of Mesoscale Circulations Characteristics Caused by the Evaporation-Efficiency of Water Retention Pavement (보수성 도로 포장재의 증발효율 변화에 의한 중규모 순환장 특성 분석)

  • Kim, In-Su;Lee, Soon-Hwan;Kim, Hae-Dong;Suh, Young-Chan
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.709-720
    • /
    • 2009
  • Field observation and numerical experiments were conducted to understand the impact of water retention pavement on the surface heat budget and on the regional circulation. The numerical model applied in this study is the atmospheric dynamic model Local Circulation Model (LCM) with two dimensional grid system, and a field observation was carried out under the clear sky and calm conditions of the weather on 19 July 2007. In the field observation, the maximum value of surface temperature on pavement covered with water retention material reached the $41.2^{\circ}C$ at 1430 LST and the values was lower for $16.1^{\circ}C$ than that of asphalt without the material. The Case BET03 assumed to be 0.3 for the surface evaporation efficiency was in good agreement with the observation and its sensible and latent heat fluxes were numerically estimated to be 229 and 227 $W/m^2$, respectively. Results of the numerical experiments demonstrated that the water retention pavement tends to induce the increase of latent heat flux associated with the lower surface temperature and mixing height during the daytime. Discontinuity of latent heat caused by the water retention pavement also tends to promote the development of mesoscale circulation called as land-land breeze or country breeze.

Cold Surges over Korean Peninsula Associated with Arctic Oscillation and the Role of Heat Source (극 진동에 연관된 한반도 한파와 열원의 역할)

  • Shin, Sung-Chul;Kim, Maeng-Ki;Lee, Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.27 no.3
    • /
    • pp.302-312
    • /
    • 2006
  • This study has investigated the effect of Arctic Oscillation (AO) on cold surge through atmospheric circulation and heat source analysis for the past winters from 1979 to 2004. The number of occurrence of cold surge in the negative AO phase is about 14.3% larger than that in the positive AO phase. The number of occurrence of cold surge per a month in the negative (positive) AO phase is about 1.33 (1.05), respectively, indicating that the negative AO phase has about 26.6% larger occurrence than the positive AO phase. It means that the cold surge has occurred frequently in particular months with the negative AO phase. And it also shows that surface temperature in the negative AO phase is about $0.6^{\circ}C$ lower than in positive AO phase. As a result of the analysis for the difference of heat source according to the intensity of AO, it shows that surface air temperature around the Korean peninsula in the negative AO phase is more lower than in positive AO phase by the intensification of cold advection term. However, heat source term cancels out the cooling effect by cold advection term, indicating that it suppresses the decrease in surface air temperature. It results in a small difference of $0.6^{\circ}C$ in surface air temperature between the positive and negative AO phase in spite of the significance of atmospheric circulation change.

Design and Thermal Analysis of Focal Plane Assembly Cooling Unit of Earth Observation Camera (저궤도 지구관측위성 주탑재체 냉각유닛 설계와 열해석)

  • Seo, Joung-Ki;Cho, Hee-Ken;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin;Kang, Seok-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.580-585
    • /
    • 2009
  • Thermal analysis and design of FPA(Focal Plane Assembly)-CU(Cooling Unit) for Earth observation camera is performed. FPA-CU is the first cooling device for a spacecraft which is designed and manufactured by its own technology in Korea. FPA-CU has a special feature, TBM(Thermal Buffer Mass) which is discriminated from typical cooling devices using heat pipes and radiator. TBM can be regarded as a thermal energy reservoir and it shows thermally transient characteristics, which make it difficult to design the size and shape of TBM. In current study, a method to determine the volume and the size of TBM is proposed and validated. The transient thermal analysis for FPA-CU for 5 operational scenarios is performed and validates the final design of FPA-CU (Radiator,TBM, Heat pipe I/F). In case of an abnormal operation of a heat pipe among three radiator heat pipes, the temperature of FPA can be increased $3{\sim}4^{\circ}C$ according to the numerical simulation.