• Title/Summary/Keyword: Early hydration behaviour

Search Result 6, Processing Time 0.024 seconds

Early Hydration of Portland Cement-Blast furnace Slag System by Impedance Techniques (임피던스 측정법을 이용한 포틀랜드 시멘트 -고로 슬래그계의 초기수화)

  • 송종택;김훈상;황인수
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.99-107
    • /
    • 2002
  • Impedance Spectroscopy (IS) has been used to study microstructure and hydration mechanism of cement pastes. In this work, the early hydration behaviour of portland cement paste with different blame values and contents of blast-furnace slag was investigated by IS. As slag was added to portland cement, the values of $R_{t(s+1)}$ (the solid-liquid phase resistance) and $R_{t(int)}$ were decreased in the early hydration period. It showed that hydration of cement paste containing slag was slower than it of the reference cement paste. As the content of slag was increased, the values of $R_{t(s+1)}$ was decreased. Furthermore, the diameter of semicircle, $R_{t(int)}$ observed at 72 hours was decreased with the increment of slag content. However, the values of $R_{t(s+1)}$ and $R_{t(int)}$ were increased with blame value of slag from the early hydration period.

Hydration of Portland Cement Containing Blending Components by Impedance Spectroscopy (임피던스 측정에 의한 혼합재를 포함한 포틀랜드 시멘트의 수화)

  • 송종택;김훈상;배승훈
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.540-549
    • /
    • 2002
  • In this work, the hydration behaviour of portland cement pastes containing fly ash, blast-furnace slag and silica fume is investigated by Impedance Spectroscopy(IS). As fly ash or blast-furnace slag was added to portland cement, the values of R$_{t(s+1)}$ and R$_{t(s+1)}$ were decreased in the early hydration period. It showed that hydration of cement containing blending components was slower than it of the reference cement paste with the same W/C ratio. However, the cement paste containing silica fume had a large value of R$_{t(s+1)}$ and R$_{t(int)}$due to very rapid pozzolanic reactivity of silica fume in the hydration time. In OPC-fly ash system, a characteristic plateau region appeared between straight-line and semicircle. The plateau region continued to grow in range with the content of fly ash and the hydration time.

A 3-dimensional Finite Element analysis of the Temperature and Stress Development in Mass Concrete Pier due to Heat of Hydration (매스콘크리트 교각의 수화열에 의한 온도 및 응력 거동에 대한 3차원 유한요소 해석)

  • 주영춘;김은겸;신치범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.928-933
    • /
    • 1998
  • The temperature and stress behaviour of mass concrete pier at early ages was analysed based on the finite element method. The pier investigated is a three-dimensional structure of which the cross-sectional shape varies from a circle to an ellipsoid along the longitudinal axis. In order to obtain the transient temperature and stress distributions in the structure, a three dimensional method was adopted, because the structure of this type cannot be modeled accurately by a two-dimensional method. Temperature analysis was performed by taking into consideration of the cement type and content, boundary and environment conditions including the variations of atmospheric temperature and wind velocity. The results of this study may be useful for the temperature control to restrain thermal cracking and the construction management to design the resonable curing method of mass concrete structure.

  • PDF

Synthesis and Properties of Calcium Sulfoaluminate Clinker Using Waste Shell, Spent Oil-Refining Catalyst and Desulfurized Gypsum (폐패각-정유폐촉매-배연탈황석고를 사용한 Calcium Sulfoaluminate 클링커의 합성과 특성)

  • Lee, Keon-Ho;Song, Tae-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.7 s.278
    • /
    • pp.483-489
    • /
    • 2005
  • For the raw materials of 3CaO$\cdot$3Al$_{2}$O$_{3}$ $\cdot$CaSO$_{4}$(CSA) clinker manufacturing, the applications of industrial wastes such as waste shell, spent oil-refining catalyst and desulfurized gypsum were examined. The c1inkerbility of the raw mix and the behaviour of formation of clinker minerals were studied and then some hydraulic properties of cements containing the clinker were also investigated. By virtue of the high reactivity of thermally decomposed raw materials, CSA clinkers were obtained at relatively low temperature of 1250$^{\circ}C$ and thus oil-refining catalysts were more desirable than aluminium hydroxide as an aluminous raw material. The expansive cement samples showed somewhat lower flow value than that of OPC, but their compressive strengths were developed earlier and higher than that of OPC due to formation of ettringite in the early hydration time, which indicated the possibility of practical use of low-cost CSA clinker using industrial wastes only.

The study of strength behaviour of zeolite in cemented paste backfill

  • Eker, Hasan;Bascetin, Atac
    • Geomechanics and Engineering
    • /
    • v.29 no.4
    • /
    • pp.421-434
    • /
    • 2022
  • In the present study, reference samples were prepared using ore preparation facility tailings taken from the copper mine (Kure, Kastamonu), Portland cement (PC) in certain proportions (3 wt%, 5 wt%, 7 wt%, 9wt% and 11 wt%), and water. Then natural zeolite taken from the Bigadic Region was mixed in certain proportions (10 wt%, 20 wt%, 30 wt% and 40 wt%) for each cement ratio, instead of the PC, to prepare zeolite-substituted CPB samples. Thus, the effect of using Zeolite instead of PC on CPB's strength was investigated. The obtained CPB samples were kept in the curing cabinet at a temperature of 25℃ and at least 80% humidity, and they were subjected to the Uniaxial Compressive Strength (UCS) test at the end of the curing periods of 3, 7, 14, 28, 56, and 90 days. Except for the 3 wt% cement ratio, zeolite substitution was observed to increase the compressive strength in all mixtures. Also, the liquefaction risk limit for paste backfill was achieved for all mixtures, and the desired strength limit value (0.7 MPa) was achieved for all mixtures with 28 days of curing time and 7 wt%, 9 wt%, 11 wt% cement ratios and 5% cement - 10% zeolite substituted mixture. Moreover, the limit value (4 MPa) required for use as roof support was obtained only for mixtures with 11% cement - 10% and 20% zeolite content. Generally, zeolite substitution seems to be more effective in early strength (up to 28th day). It has been determined that the long-term strength losses of zeolite-substituted paste backfill mixtures were caused by the reaction of sulfate and hydration products to form secondary gypsum, ettringite, and iron sulfate.

A Study on Chloride Binding Capacity of Various Blended Concretes at Early Age (초기재령에서 각종 혼합콘크리트의 염소이온 고정화능력에 관한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.133-142
    • /
    • 2008
  • This paper studies the early-aged chloride binding capacity of various blended concretes including OPC(ordinary Portland cement), PFA(pulversied fly ash), GGBFS(ground granulated blast furnace slag) and SF(silica fume) cement paste. Cement pastes with 0.4 of a free water/binder ratio were cast with chloride admixed in mixing water, which ranged from 0.1 to 3.0% by weight of cement and different replacement ratios for the PFA, GGBFS and SF were used. The content of chloride in each paste was measured using water extraction method after 7 days curing. It was found that the chloride binding capacity strongly depends on binder type, replacement ratio and total chloride content. An increase in total chloride results in a decrease in the chloride binding, because of the restriction of the binding capacity of cement matrix. For the pastes containing maximum level of PFA(30%) and GGBFS(60%) replacement in this study, the chloride binding capacity was lower than those of OPC paste, and an increase in SF resulted in decreased chloride binding, which are ascribed to a latent hydration of pozzolanic materials and a fall in the pH of the pore solution, respectively. The chloride binding capacity at 7 days shows that the order of the resistance to chloride-induced corrosion is 30%PFA > 10%SF > 60%GGBFS > OPC, when chlorides are internally intruded in concrete. In addition, it is found that the binding behaviour of all binders are well described by both the Langmuir and Freundlich isotherms.