An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

스프링클러 헤드의 응답시간지수 측정 (A Study on Response Time Index for Sprinkler Head)

  • 태순호;이병곤
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.51-55
    • /
    • 1990
  • This study describes the engineering approach adopted to investigate sprinkler head during the early stage of a fire when they are subjected to convective heating and low gas velocities. Comparions are made between the parameters derived using basic methods, ie. ramp test, for evaluating sprinkler parameters(time constant, response time index) is illustrated. Evidence is presented that the propotion of heat loss by conduction from a sprinkler element may very typically employed in the rate of rise test. This fact alone may justfy the precautionary need to perform a limited number of rate of rise tests to confirm a sprinklers capacity to function correctly in reasonably unfavourable yet realistic conditions. The work is aimed primarily at meeting the needs of sprinkler industry.

  • PDF

[논문철회]노인관련시설에서 조기반응형 스프링클러헤드의 유용성 ([Retracted]Evaluation of Early Suppression-Fast Response (ESFR) Sprinklers in Facilities and Residences for Elderly People)

  • 최영상;공예린;공하성
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.15-20
    • /
    • 2015
  • 이 연구는 노인관련시설에 스프링클러 설치유무와 종류에 따른 연기층 및 공기층의 온도변화와 연기층의 높이변화를 화재시뮬레이션을 통해 비교한 것으로 복사열은 거실에 표준반응형 헤드가 작동한 경우는 플래시오버 발생조건을 초과하였으나 조기반응형 헤드는 플래시오버가 발생되지 않는 것으로 나타났다. 인체표면의 경우도 조기 반응형 헤드가 작동하면 열유속의 최대값이 $2,293W/m^2$에 머물러 인체화상 위험조건인 $4,000W/m^2$ 이하가 되어 거주자가 열에 의해 인체화상은 입지 않는 것을 알 수 있다. 화재실의 최고온도는 연기층 및 공기층 모두 인명안전기준을 초과하였으나 일정시간 후 급격히 하강하여 인명안전기준에서 요구하는 온도 이하로 유지되는 것을 알 수 있었다. 연기층의 높이는 조기반응형 헤드가 작동하면 연기층을 1.1 m 이상으로 유지할 수 있어서 표준반응형 헤드가 작동한 경우보다 연기층 하강을 더 지연시킬 수 있음을 알 수 있다.

저성장속도 화재에서의 스프링클러 헤드 동작특성에 관한 실험적 연구 (An Experimental Study on Characteristics of Sprinkler Head Activation in Low Growth Rate Fire)

  • 최용섭;윤종칠
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.26-35
    • /
    • 2016
  • 스프링클러 설비는 화재 발생 시 화재를 초기에 제어 및 진압하는 설비로서 어떠한 화재 분위기에서도 스프링클러 헤드의 작동온도에서 정상적인 동작을 하여야 한다. 그러나 최근 화재성장속도가 느린 화재 발생 장소에서 일부 조기반응형 스프링클러 헤드가 정상적인 동작을 하지 않을 수 있다는 문제가 제기되고 있다. 이에 본 논문에서는 공동주택 침실규모의 모형실험 및 캐비넷형 버너를 이용하여 화재성장속도가 느린 조건을 형성하고 실제 현장에서 배관 내에 가해지는 최소압력인 0.2MPa 이상의 가압수를 공급하여 실험을 진행하였다. 실험결과 국내에서 사용되고 있는 과반수 이상의 플러쉬형 조기반응형 스프링클러 헤드에서 Cold Soldering 현상이 발생되면서 불완전하게 개방되는 것이 확인되었다. 이러한 현상은 화재 조기진압 및 제어에 실패하여 화재확산 및 인명피해의 원인이 될 수 있으므로 추가적인 연구를 통해 국내 형식승인 및 제품검사기준의 보완의 필요할 것으로 판단된다.

풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구 (Study on the Operation Characteristics of Heat Detectors through Fire and Wind Tunnel Experiment)

  • Ryu, Hocheol;Kim, Doohyun
    • 한국재난정보학회 논문집
    • /
    • 제11권2호
    • /
    • pp.203-209
    • /
    • 2015
  • 열감지기는 화재시 발생되는 열을 감지하는 것으로 모든 소방대상물에 일반적으로 사용되는 자동화재탐지설비의 중요한 핵심 요소이다. 열감지기는 스포트(spot)형과 분포형으로 구분되며, 스포트형에는 차동식과 정온식이 있다. 이러한 열감지기는 실제 화재시 작동시간 및 작동온도 등 반응의 민감도에 따라 인명과 재산 손실에 큰 영향을 준다. 국내에서는 스프링클러 헤드제품에 응답시간지수를 도입하여 사용하고 있으나, 열감지기에 대해서는 현재 적용이 되어지지 않고 있으며, 반응의 민감도를 표시하는 응답시간지수의 도입이 필수적으로 본 연구에서는 국내 생산된 정온식 스포트형 열감지기와 다이아프램형 및 반도체 형식의 차동식 스포트형 열감지기에 대하여 풍동실험 및 화재실험을 통하여 응답시간지수, 작동시간, 작동온도 등에 대하여 연구하였다. 응답시간지수를 적용한 열감지기를 설치하여 신속한 경보로 인한 국민의 생명과 재산손실을 줄이는데 도움을 주고자 한다.