• Title/Summary/Keyword: EYE type

Search Result 406, Processing Time 0.024 seconds

Design of a Thrust Stand Using Flexure (플렉셔를 적용한 추력 시험대 설계)

  • Jin, Juneyub;Park, Youngseok;Lee, Changwook;Jeong, Sangseop;Lee, Juhyung;Baek, Cheulwoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.3
    • /
    • pp.205-212
    • /
    • 2021
  • In this study, two types of thrust stand modeling were proposed for the design of a thrust stand using flexure. Type A model generate combined load for tangential (thrust) and axial compressive load (self weight). And type B generate combined load for tangential and axial tensile load. The research was done by comparing the influence of the load between the models through a 1D calculation and computational analysis. The 1D calculated value and the computational analysis value were compared for a total of 10 sections and the results were confirmed to be very similar. In order to prove the validity of the analysis results, the equivalent stress was confirmed from the computational analysis of the flexure, and the production of the Type B model was selected from the evaluation of the yield condition (Von-Mises Yield Criterion).

Analysis of Astigmatism in Korean Adults from 20 to 29 Yesrs Old (20세부터 29세까지 한국인 성인 난시 분석)

  • Kim, Douk-Hoon;Park, Sang-Youl
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1478-1485
    • /
    • 2021
  • Purpose. To analysis of astigmatism in Korean adults from 20 to 29 years old. Methods. From January 2019 to February 2020, one hundred two subjects were performed in refraction test using the Auto-Refractometry. Results. In the type of astigmatism based on refractive error, the male's right eye was 4.26% simple myopic astigmatism and 95.74% complex myopic astigmatism, and the left eye was 2.22% simple myopic astigmatism and 97.78% complex myopic astigmatism. However, in the female's right eye, simple myopic astigmatism was 2.27%, complex myopic astigmatism was 97.73%, and left eye was simple myopic astigmatism was 2.17%, complex myopic astigmatism was 97.83%. The types of astigmatism in men and women similar to other. The mean refractive astigmatism values were -0.922±-0.798 diopter and -0.877±-0.707 diopter for male right and left eye, and -0.765±-0.599 diopter and -0.853±-0.586 diopter for female. On the other hand, the refraction values of the right and left eyes of men and women have statistical significance(p=0.000). The mean power comparative between refractive astigmatism and corneal astigmatism power were -0.186±-0.745 diopter, -1.091±-0.589 diopter in male and -1.140±-0.593 diopter, -1.140±-0.534 diopter in female. Therefore, the mean power values of the refractive astigmatism and corneal astigmatism of men and women were statistical significance(p=0.000). At the 0.75 diopter or more, which can have clinical symptoms of astigmatism power, males have 60.86% and 72.09% of the right and left eyes, and females have 47,64% and 60.10% of the right and left eyes. At 0.75 diopter or more, which can have clinical symptoms of corneal astigmatism power, males have 68.75% and 74% of the right and left eyes, and females have 86.50% and 82.35% of the right and left eyes. In the type of astigmatism axis, both men and women had a high frequency of the rule astigmatism. However, men had a high frequency of against-the-rule astigmatism and women showed a high frequency of oblique astigmatism. Conclusions. In this study, the complex myopic astigmatism and with-the rule astigmatism was the most common of all subjects. However, there was a statistical significance between right and left eyes of all subjects. The corneal astigmatism was higher refractive values in both males and females than refractive astigmatism. This study suggests that the analysis of the astigmatism can provide the useful diagnosis information for the correction of visual acuity.

A Photogrammetic Study of the Eyes in Korean Youths (한국 청년층 눈의 사진 계측학적 연구)

  • Bae, Tae Hui;Kim, Jong Chan;Kim, Woo Seob;Kim, Han Koo;Kim, Seung Hong
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • Purpose: Photogrammetry has been introduced as an alternative to direct measurement to obtain facial distances for a variety of anthropometric applications. The aim of this study is to establish morphological and functional value of an eye in Korean youths using specially designed computer software with digital photographic images. Methods: Authors measured anthropometry of an eye in Korean youths 1,449 individuals(622 males, 827 females) and analyzed stastically them. Results: The mean measurements are as follows. The diameter of cornea was $11.6{\pm}0.9mm$ in males and $11.3{\pm}0.9mm$ in females. The vertical dimension of palpebral fissure was $7.4{\pm}1.7mm$ in males and $8.2{\pm}1.6mm$ in females. The intercanthal width was $35.8{\pm}3.2mm$ in males and $34.4{\pm}2.9mm$ in females. The biocular width was $90.4{\pm}5.7mm$ in males and $87.4{\pm}5.3mm$ in females. The endocantion-superior margin of palpebral fissure distance was $12.7{\pm}1.4mm$ in males and $11.6{\pm}1.4mm$ in females. The horizontal dimension of palpebral fissure was $28.5{\pm}2.2mm$ in males and $27.4{\pm}1.9mm$ in females. The slant of palpebral fissure was $10.7{\pm}2.6^{\circ}$ in males and $11.3{\pm}3.0^{\circ}$ in females. The height of upper eyelid was $10.6{\pm}2.3mm$ in males and $10.7{\pm}2.3mm$ in females. The width of double fold was $2.0{\pm}0.7mm$ in males and $1.9{\pm}0.6mm$ in females. A double fold was seen in 21.9% of males and 44.9% of females. The most frequent shape of the double fold was type IV. The most common type of epicanthal fold was type III in both males and females. Conclusion: Photogrammetic measurement of large population using specially designed software could offer reliable data and these data could be useful reference for preoperative consultation, surgical planning and anthropometic study of eye.

Comparative Analysis of the Extracellular Matrix Composition in Proliferating and Involuted Infantile Hemangiomas

  • Park, Hyochun;Park, Hannara;Chung, Ho Yun;Teresa, MO;Waner, Milton
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.544-551
    • /
    • 2015
  • Background Changes in the composition of the extracellular matrix (ECM) occur between the proliferating and involuted phases of infantile hemangiomas (IH), and are associated with angiogenic growth. We examined the composition of the ECM in proliferating and involuted IHs and assessed correlations between the composition of the ECM and whether the IH was in the proliferating or the involuted phase. Methods We evaluated IH samples from a cohort of patients who had five proliferating IHs and five involuted IHs. The following ECM molecules were analyzed using enzyme-linked immunosorbent assays and immunohistochemistry: laminin, fibronectin, collagen type I, collagen type II, and collagen type III. Results The involuted IHs had higher levels of deposition of collagen type III than the proliferating IHs. The median values (interquartile ranges) were 1.135 (0.946-1.486) and 1.008 (0.780- 1.166) (P=0.019), respectively. The level of laminin was higher in involuted IHs than in proliferating IHs, with median values (interquartile ranges) of 3.191 (2.945-3.191) and 2.479 (1.699- 3.284) (P=0.047), respectively. Abundant collagen type III staining was found in involuted IHs. Laminin ${\alpha}4$ chain staining was clearly present within the basement membrane adjacent to the blood vessels, and was significantly more intense in involuted IHs than in proliferative IHs. Conclusions Involuted hemangiomas showed extensive deposition of collagen III and laminin, suggesting that differences in the composition of the ECM reflect stages of the development of IHs. This pattern may be due to the rapid senescence of IHs.

Existence of "25 kDa Thiol Peroxidase" in Retina: Evidence for An Antioxidative Role

  • Cha, Mee-Kyung;Kim, Il-Han
    • BMB Reports
    • /
    • v.31 no.4
    • /
    • pp.409-412
    • /
    • 1998
  • We isolated and sequenced a human retina cDNA fragment that encodes 25 kDa thiol peroxidase. A search of a databank showed that the 25 kDa thiol peroxidase from retina is the same type of thiol peroxidase which exists in human brain and red blood cells. This type of tbiol peroxidase was distributed in all of the tested tissues including retina. This result suggests a physiological role for the 25 kDa thiol peroxidase as an important antioxidant.

  • PDF

A Study on the Health Status of Some Industrial Workers in Seoul. (서울시내 일부 산업근로자들의 건강상태에 관한 조사연구)

  • 오세중
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.13-22
    • /
    • 1977
  • In an attempt to evaluate working conditions and hazardous environmental factors, a survey on health problems was conducted for 721 employees from 18 industrial plants in Young Dung Po and Sung Dong districts of Seoul in the period from May 1975 to Feb, 1976. The questionnaire and survey was inclusive of all illnesses known as most common to industrial workers (according to the report by Korea Industrial Health Association) of this country and envi ronmental factors pointed out by the workers. The results were as following. 1. The over whelming majority of complaints were psychiatric, ear,eye, and digestive disorders. 2. Those whose work time is the longest have a propotionately higer incidence of complaints especially in eye,ear, neuromusculoskeletal, and neurosensory systems. 3. In females whose occupational history is relatively short, a higher incidence of digestive and skin section disorders was noted and this is especially true among those working in night shift. 4. Among machinery industry workers, most complaints were of eye, ear, and neuro musculoskeletal disturbances, and this fact seems to be closely related to physical over works. 5. Dust and noise were pointed out by the largest number of workers as undisirable conditions in work environment. 6. Distribution of complaints are closely related to the type of industry, and in comparison with the result reported by Korea Industrial Health Association in 1972, the prevalence rates of occupational disorder were similar in our study,

  • PDF

Perception of Ship's Movement in Docking Maneuvering using Ship-Handling Simulator

  • Arai, Yasuo;Minamiya, Taro;Okuda, Shigeyuki
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.3-10
    • /
    • 2006
  • Recently it is coming to be hish reality on visual system in ship-handling simulator depending on the technical development of 3D computer graphics. Even with high reality, it is possible that visual information presented seafarers through screen or display is not equivalent to the real world. In docking maneuvering, visual targets or obstructs are sighted close to ship's operator or within few hundred meters, so it might be possible to affect visual information such as the difference between both eyes' and single eye's visual sight. Because it is not possible to perceive of very slow ship's movement by visual in case of very large vessels, so the Doppler Docking SONAR and/or Docking Speed and Distance Measurement Equipment were developed and applied for safety docking maneuvering. By the way, the simulator training includes the ship's maneuvering training in docking, but in Ship-handling Simulator and also onboard, there are some limitations of perception of ship's movement with visual information. In this paper, perception of ship's movement with visual system in Ship-handling Simulator and competition of performances of visual systems that are conventional screen type with Fixed Eye-point system and Mission Simulator. We got some conclusions not only on the effectiveness for visual system but also on the human behavior in docking maneuver.

  • PDF

Aspherical prism lens design and manufacture of a small size and light wight EGD (비구면 프리즘 렌즈를 이용한 소형 경량의 EGD용 광학계 설계 및 제작)

  • Kim, Tae-Ha;Park, Kwang-Bum;Kim, Mi-Jung;Park, Young-Su;Kim, Hwi-Woon;Moon, Hyun-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.454-454
    • /
    • 2007
  • Eye Glass Display (EGD) with microdisplay to realize the virtual display can make the large screen, so virtual image has been developed by using microdisplay panel. This paper shows study of spherical prism lens design and manufacture of a small size and light weigh EGD with 0.59" OLED panel. Code V is used and it designed an aspherical prism lens about eye relief 25mm and 42 degree of filed of view (FOV). With the application this aspheric prism lens to OLED type's microdisplay, virtual image showed 60 inch at 2m. It had less than 2% of distortion value and modulation transfer function in axial had 30% of resolution with 32 lp/mm spatial frequency. We made an injection molding bases to lens designed.

  • PDF

"Letter-Box" Conjunctival Flap in a Dog with Severe Corneal Edema after Phacoemulsification

  • Sunhyo Kim;Dohyoung Kwon;Kangmoon Seo;Seonmi Kang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.152-157
    • /
    • 2023
  • A two-year-old, spayed female, Bichon Frise, was referred for severe corneal edema and corneal ulcer in the left eye (OS). The cornea had gradually swelled over one week after phacoemulsification performed a month prior, and that was refractory to 5% sodium chloride eye drop instillation or temporary partial tarsorrhaphy. A complete ophthalmic examination was performed. Severe corneal edema with intrastromal bullae and moderate anterior chamber flare was found on slit-lamp biomicroscopy in the OS, which obstructed the fundus examination. Corneal thickness was measured using high-resolution ultrasound biomicroscopy. The thickness of the OS cornea was 2.74 mm. The "letter-box" conjunctival flap was planned. Dorsal and ventral superficial keratectomy followed by a hood conjunctival flap was performed. Topical and systemic antibiotics and 5% sodium chloride eye drops were prescribed. Decreased corneal thickness was observed at one week, two weeks, and two months postoperatively (1.53 mm, 1.32 mm, and 0.92 mm, respectively). There were no postoperative complications, such as ocular discomfort or recurrent corneal ulcers. The "letter-box" conjunctival flap, a type of superficial keratectomy and conjunctival advancement hood flap, effectively relieved the severe irreversible corneal edema. This could be a simple but effective surgical intervention for patients with endothelial cell damage especially after phacoemulsification.

Multi-focus 3D display of see-through Head-Mounted Display type (투시형 두부 장착형 디스플레이방식의 다초점 3차원 디스플레이)

  • Kim, Dong-Wook;Yoon, Seon-Kyu;Kim, Sung-Kyu
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.441-447
    • /
    • 2006
  • See-through HMD type 3D display can provide an advantage of us seeing virtual 3D data used stereoscopic display simultaneously with real object(MR-Mixed Reality). But, when user sees stereoscopic display for a long time, not only eye fatigue phenomenon happens but also de-focus phenomenon of data happens by fixed focal point of virtual data. Dissatisfaction of focus adjustment of eye can be considered as the important reason of this phenomenon. In this paper, We proposed an application of multi-focus in see-through HMD as a solution of this problem. As a result, we confirmed that the focus adjustment coincide between the object of real world and the virtual data by multi-focus in monocular condition.