• Title/Summary/Keyword: ETFE membrane

Search Result 20, Processing Time 0.024 seconds

Preparation and Characterization of Ionic Permselective Membrane by Radiation Grafting for Vanadium Redox Flow Battery (방사선을 이용한 바나듐 레독스 흐름전지용 이온 투과선택성 분리막의 제조 및 특성 평가)

  • Sohn, Joon-Yong;Song, Ju-Myung;Shin, Junhwa
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed ionic permselective membrane as a core material of redox flow battery using radiation grafting method. Two ionic permselective membranes, ETFE-g-PSSA and ETFE-g-PVBSA were prepared by radiation grafting with styrene and VBC followed by sulfonation, respectively. We confirmed that the prepared membranes were successfully prepared via FT-IR. The prepared ionic permselcetive membranes were characterized and the performance of the membranes were evaluated as ionic permselective membranes for vanadium redox flow battery.

A Study on the Radiolytic Synthesis of PVBC-grafted ETFE Films and Their Quaternarization with Diamines for the Preparation of Anion Exchange Membranes (음이온 교환막 제조를 위한 염화비닐벤질 고분자가 그라프트된 ETFE 필름의 방사선 합성과 디아민류와의 4차 아민화에 관한 연구)

  • Ko, Beom-Seok;Sohn, Joon-Yong;Nho, Young-Chang;Shin, Junhwa
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.179-184
    • /
    • 2011
  • In this study, several anion exchange membranes were successfully prepared by radiation grafting of vinylbenzyl chloride (VBC) monomer onto a polyethylene-co-tetrafluoroethylene (ETFE) film and subsequent quaternarization with diamins such as 1,4-diazbicyclo[2,2,2]octane, N,N,N',N'-tetramethyl-1,3-diaminopropane, N,N,N',N'-tetramethyl-1,6-diaminohexane, and trimethylamine. The anion exchange capacities of the prepared membranes were determined by using acid-base titration method. The cross-sectional morphology of the membranes was studied by using SEM instrument. The cross-sectional distribution patterns of the grafted polymers with anion exchange functional groups were also studied by EDX analysis.

Basic Test on the Mechanical Characteristics of Polyester Membrane (폴리에스터 막재의 역학적 특성에 관한 기초시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Lee, Jang-Bok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of architectural membrane have fire proofing, lack of strength, tear resistance, durability and elasticity. For the estimation of this problems, it will be tested the basic mechanical properties of membrane material about tensile strength, tearing resistance and repeated loading behavior. Elastic modulus is 337.30~1257.63N/$mm^2$, and strain is 17.90~26.91%.

  • PDF

Radiolytic Preparation and Characterization of Poly(styrene sulfonic acic)-grafted ETFE Membranes (스타이렌 술폰산 고분자가 그래프트된 ETFE 막의 방사선 제조 방법 및 특성 분석)

  • Ko, Beom-Seok;Kang, Sung-A;Fei, Geng;Jeun, Joon-Pyo;Nho, Young-Chang;Kang, Phil-Hyun;Kim, Chong-Yeal;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.20-24
    • /
    • 2010
  • In this study, ETFE-g-PSSA membranes with various degrees of grafting (DOG) and thicknesses were prepared by a simultaneous irradiation method. SEM-EDX instrument was applied to measure the relative distribution of sulfur which is corresponding to that of a grafted polymer over the Cross-section of the ETFE-g-PSSA membranes prepared at various irradiation conditions. The results indicate that to obtain the evenly-grafted membranes, a styrene/dichloromethane ratio is needed to be under 60 (v/v%), and a higher DOG is required as the film thickness increases. The effects of DOG and thickness on the ion exchanging capacity (IEC) and water uptake (WU) were investigated by measuring the IEC and WU values of the membranes with various DOG and thicknesses.

Application of Diffusion Models to Anomalous Sorption in Fluoropolymer-aromatic Solvent Systems (불소고분자-방향족 용매계의 비이상적 흡수에 대한 확산 모델식의 적용)

  • 이상화
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.139-147
    • /
    • 2000
  • Non-Fickian (or anomalous) diffusion was observed in transient sorption of aromatic solvents(such as benzene, toluene, and chlorobenzene) in fluoropolymers (such as ETFE, ECTFE and PVDF). In this study, five other transient sorption models (Crank, Long & Richman, Berens & Hopfenberg, Neogi, Li) based on Fick's law were employed to fit the anomalous sorption data for aromatic solvents. The adjustable parameters were determined by least square analysis of the measured and predicted fractional uptake. For ETFE sorption data slightly deviating from Fickian behavior, all the models exhibited satisfactory results in fitting the anomalous sorption data. In particular, Neogj model predicted intrinsic diffusivity (0.4~0.8$\times$10$^{-5}$ $\textrm{cm}^2$/day) and equilibrium diffusivity (0.13~0.31$\times$10$^{-4}$ $\textrm{cm}^2$/day) as well as relaxation kinetics related to non-Fickain diffusion. For a typical sigmoidal sorption behavior in PVDF, only Crank's model could give the reasonable evaluation on transport properties. The ratio of intial diffusivity (D$_{i}$) to final equilibrium diffusivity (D$_{\infty}$) was ranged from 80 to 200. For the final stage of uptake In ECTFE with drastic acceleration, all the models exhibited significant deviations from the sorption data. New diffusion models based on thermodynamics and continuum mechanics should be employed to get valuable information on transport properties as well as relaxation kinetics coupled with non-Fickian diffusion.

  • PDF

Fabrication of Silane-crosslinked Proton Exchange Membranes by Radiation and Evaluation of Fuel Cell Performance (방사선을 이용한 실란 가교구조의 유/무기 복합 수소이온 교환막 제조 및 연료전지 성능 평가)

  • Lee, Ji-Hong;Sohn, Joon-Yong;Shin, Dong-Won;Song, Ju-Myung;Lee, Young-Moo;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.525-530
    • /
    • 2012
  • In this study, silane-crosslinked organic/inorganic composite membranes were prepared by simultaneous irradiation grafting of binary monomer mixtures (styrene and 3-(trimethoxysilyl)propyl methacrylate (TMSPM)) with various compositions onto a poly(ethylene-alt-tetraethylene) (ETFE) film and followed by sol-gel processing and sulfonation to provide a silane-crosslinked structure and a proton conducting ability, respectively. The Fourier transform infrared spectroscopy (FTIR) and thermo gravimetric analysis (TGA) were utilized to confirm the crosslinking of ETFE-g-PS/PTMSPM films. The prepared membranes with similar ion exchange capacity but a different TMSPM content were selected and their membrane properties were compared. The ETFE-g-PSSA/PTMSPM membranes were characterized by water uptake, dimensional stability, and proton conductivity after sulfonation. The membrane electrode assemblies (MEA) of the prepared membranes were fabricated and their single cell performances were measured.

Flame Resistance Performance of Glass Fiber and Polyester Fiber Architectural Membranes (건축용 유리섬유 및 폴리에스테르섬유 막재의 난연특성)

  • Kim, JiHyeon;Song, Hun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2016
  • Membrane structures can be used to create diverse lightweight structural forms using ductile membranes made of coated fabric. Using membrane structures, it is possible to construct large covered spaces relatively quickly and economically, and hence, they are being applied within various applications. The structures are light-weight, transparent, flexible in their application, economical and easy to maintain, and as such, their usage is being expanded. However, despite their prevalence, the standard for membrane material performance in terms of fire safety is still inadequate, and the development of membrane materials with excellent flame resistance performance is being demanded. This study determined flame resistance performance of architectural membranes, including PTFE, PVDF, PVF and ETFE film membranes, through flammability testing and incombustibility testing.

Study on Corrosion Problems in PEMFC Cooling System (PEMFC 냉각 시스템의 물부식 방지에 관한 연구)

  • Park, Kwang-Jin;Jeong, Jae-Hwa;Kim, Jung-Hyun;Bae, Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1188-1193
    • /
    • 2007
  • This study focuses on the corrosion problems of STS316(stainless steel 316) tube for the cooling system of PEMFC (Proton Exchange Membrane Fuel Cell) operation. Deionized water which is highly corrosive is used especially for cooling agent of PEMFC to eliminate electrical conductivity, The tensile stress analysis was performed to check the change of mechanical strength of cooling line and pH of the water was monitored for the observation of extent of corrosion at simulated PEMFC operating condition. When STS316 tube was exposed to deionized water for 500 hours, substantial cracks were found on the surface and the pH of water was decreased from 6.8 to 5.8. For prevention of corrosion problems, the STS316 was coated by three kinds of fluororesin such as PTFE, FEP and ETFE. Among the coating materials, PTFE was the most protective in corrosive environment and was maintained the mechanical strength. To lower the cost, the same experimental analyses were carried out for iron tubes and the result will be discussed in detail.

Mechanical Characteristic Test of Architectural ETFE Film Membrane (크기최적화 이후에 나타나는 공간구조물의 후 좌굴 거동 변화에 대한 연구)

  • Lee, Sang-Jin;Jung, Ji-Myoung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.3
    • /
    • pp.75-82
    • /
    • 2009
  • This paper investigates the variation of post-buckling behaviours of spatial structures after sizing optimization with linear assumptions. The mathematical programming technique is used to produce the optimum member size of spatial structures against external load. Total weight of structure is considered as the objective function to be minimized and the displacement occurred at loading point and member stresses of structures are used as the constraint functions. The finite difference method is used to calculate the design sensitivity of objective function with respect to design variables. The post-buckling analysis carried out by using the geometrically nonlinear finite element analysis code ISADO-GN. It is found to be that there is a huge difference between the post buckling behaviours of the initial and optimized structures. Therefore, the stability of optimized spatial structures with linear assumption should be throughly checked by appropriate nonlinear analysis techniques. Finally, the present numerical results are provided as benchmark test suite for future study of large spatial structures.

  • PDF