• 제목/요약/키워드: ESI tandem mass spectrometry

검색결과 99건 처리시간 0.026초

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

  • Lee, Jaeick;Lee, Seunghwa;Kim, Byungjoo;Lee, Joonhee;Kwon, Oh-Seung;Cha, Eunju
    • Mass Spectrometry Letters
    • /
    • 제9권1호
    • /
    • pp.30-36
    • /
    • 2018
  • A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • 한국식품위생안전성학회지
    • /
    • 제32권2호
    • /
    • pp.89-95
    • /
    • 2017
  • 에너지 음료는 카페인을 주성분으로 타우린, 비타민 같은 다른 energy-enhancing 성분을 함유하고 있다. 미국과 유럽에서는 글루쿠로노락톤이 에너지 음료에 첨가될수 있으나, 국내에서 의약품으로는 허가되어 있다. 따라서 식품 첨가물로는 그 사용이 금지 되어 있어, 지속적으로 수입 및 유통 음료에서 시험검사를 하여 규제하고 있다. 현재 분석법으로 사용하는 LC-PDA 법은 복잡한 유도체화 과정을 거치고, 음료 중에 당류들이 위양성 결과를 나타내기도 한다. 이런 기존 방법의 단점을 개선하기 위해 HILIC-ESI-MS/MS(hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry)를 이용한 분석법을 개발하고, 선택성, 직선성, 검출한계, 정량한계, 정밀도, 정확성, 재현성에 대하여 분석법 유효성 검증을 수행했고, AOAC, EURACHEM 가이드라인에 부합되는 결과를 얻었다.

Oligomer Complexes of the (VQIVYK + NNQQNY) and (VQIVYK + LYQLEN) Mixing Solutions

  • Jung, Yeon-Ji;Shin, Min-Ji;Kim, Ho-Tae
    • Mass Spectrometry Letters
    • /
    • 제10권1호
    • /
    • pp.32-37
    • /
    • 2019
  • The ${\pi}-{\pi}$ interactions of the peptide-dimer and peptide-trimer complexes were investigated in the (VQIVYK + LYQLEN) and (VQIVYK + NNQQNY) mixing solutions. The results showed that tyrosine (Y) residues were critical in the formation of hetero peptide-dimers and -trimers during the early oligomerization process. We used collision-induced dissociation (CID) along with electrospray ionization mass spectroscopy (ESI-MS) to obtain the structural information of the hetero-dimers and -trimers. We chose three amyloidogenic peptides-VQIVYK, NNQQNY, and LYQLEN-from tau protein, yeast prion-like protein Sup35, and insulin chain A, respectively. Hetero-dimer, -trimer, -tetramer, and -pentamer complexes were observed in the mass spectra. The tandem mass spectrum of the hetero-dimer and hetero-trimer showed two different fragmentation patterns (covalent and non-covalent bond dissociation). Y-Y interaction structures were also proposed for the hetero-dimer and -trimer complexes.

Comparative Proteomic Analysis of Human Amniotic Fluid Supernatants with Down Syndrome Using Mass Spectrometry

  • Park, Ji-Sook;Cha, Dong-Hyun;Jung, Jin-Woo;Kim, Young-Hwan;Lee, Sook-Hwan;Kim, Young-Jun;Kim, Kwang-Pyo
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권6호
    • /
    • pp.959-967
    • /
    • 2010
  • Down syndrome (DS) is an abnormality of the 21st chromosome that commonly occurs in children born to older women. Thus, amniotic fluid (AF) is usually collected from such women for prenatal diagnosis. This study analyzed human AF supernatants (AFS) using a mass spectrometric (MS) approach to search for candidate biomarkers of a DS pregnancy. The AFS were collected from older pregnant women at weeks 16-18 of their gestation by amniocentesis for cytogenetic analysis. The AFS from the pregnancies carrying DS (n=4) or chromosomally normal (n=6) fetuses, as revealed by the cytogenetic analysis, were then subjected to global protein profiling based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Affinity chromatography was also applied prior to the LC-ESI-MS/MS to minimize the masking effect of highly abundant albumin and immunoglobulin and thereby increase the diversity of the identified proteins. As a result, at least 30 new AFS proteins were identified and 44 AFS proteins were found to be differentially expressed between the DS and normal cases, where 6 of the proteins were unique to the DS cases and 11 were unique to the chromosomally normal cases. In addition, in the DS cases, 19 AFS proteins were downregulated and 8 were upregulated to varying degrees. A Western blot analysis confirmed the LC-ESI-MS/MS data, indicating that the combined detection of apolipoprotein A-II (apoA-II) and alpha-fetoprotein (AFP) could be a potential tool for diagnosing DS cases.

IN VIVO METABOLISM OF 2-METHYLAMINOETHYL-4,4'-DIMETHOXY-5,6,5',6'-DIMETHYLENEDIOXYBIPHENYL-2'-CARBOXY-2-CARBOXYLATE (DDB-S) BY LC/ESI TANDEM MASS SPECTROMETRY

  • Son, Jung-Hyun;Lee, Jae-Ick;Yang, Ryung;Kim, Dong-Hyun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.251.2-251.2
    • /
    • 2002
  • 2-Methylaminoethyl- 4,4' -dimethoxy- 5, 5',6,6' -dimethylenedioxybiphenyl- 2' -carboxy- 2-carboxylate (DDB-S) is a synthetic compound derived from DDB. which is protects liver against carbon tetrachloride-, D-galactosamine-, thioacetamine-, and prednisolone- induced hepatic injury in experimental animals. We assessed the use of liquid chromatography/electrospray iontrap tandem mass spectrometry (LC/MS/MS) method to identify and quantify in vivo metabolites and to measure excretion. (omitted)

  • PDF

Development of Ultra-High Pressure Capillary Reverse-Phase Liquid Chromatography/Tandem Mass Spectrometry for High-Sensitive and High-Throughput Proteomics

  • Kim, Min-Sik;Choie, Woo-Suk;Shin, Yong-Seung;Yu, Myeong-Hee;Lee, Sang-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권12호
    • /
    • pp.1833-1839
    • /
    • 2004
  • Recently mass spectrometry and separation methods such as liquid chromatography have become major tools in the field of proteomics. In this report, we describe in detail our efforts to develop ultra-high pressure capillary reverse-phase liquid chromatography (cRPLC) and its online coupling to a mass spectrometer by a nanoelectrospray (nanoESI) interface. The RPLC system is constructed in house to deliver LC solvents at the pressure up to 20,000 psig, which is four times higher than conventional RPLC systems. The high operation pressure allows the efficient use of packed micro-capillary columns (50, 75 and 150 ${\mu}$m i.d., up to 1.5 m long). We will discuss the effect of column diameter on the sensitivity of cRPLC/MS/MS experiments and the utility of the developed technique for proteome analysis by its application in the analysis of proteome samples having different levels of complexity.

Electrospray Tandem Mass를 이용한 혈중 글리퀴돈의 정량법 개발 및 생체이용률시험 (Electrospray Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Gliquidone in Human Plasma)

  • 문철진;이은희;양송현;문해란
    • 약학회지
    • /
    • 제49권3호
    • /
    • pp.212-216
    • /
    • 2005
  • A rapid, sensitive and selective electrospray tandem mass spectrometric (ESI-LC/MS/MS) method for the quantitation of gliquidone in human plasma was developed. A bioavailability study of gliquidone tablet (30 mg gliquidone, Boehringer Ingelheim Korea Co.) was performed using the validated ESI-LC/MS/MS method. The dose of 30 mg of gliquidone (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, 24, and 33 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $10\~1000 ng/ml$. The coefficient of variation for intra- and inter-day assay were $8.30\~18.86$, and $2.19\~12.92\%$, respectively. The lower limit of quantification for gliquidone was 10 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 3861.17$\pm$1328.61 ng-hr/ml, $C_{max}$ was 831.02$\pm$227.99 ng/ml, $T_{max}$ was $2.94{\pm}0.77 hr,\;K_e$, was 0.19$\pm$0.06 1/hr, and $t_{l/2}$ was 4.47$\pm$3.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of gliquidone dosage forms was prepared successfully and could be used for the bioequivalence test of gliquidone preparation.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Rapid Screening of Phospholipid Biomarker Candidates from Prostate Cancer Urine Samples by Multiple Reaction Monitoring of UPLC-ESI-MS/MS and Statistical Approaches

  • Lim, Sangsoo;Bang, Dae Young;Rha, Koon Ho;Moon, Myeong Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1133-1138
    • /
    • 2014
  • Ultrahigh performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI- MS/MS) provides a high-speed method to screen a large number of samples for small molecules with specific properties. In this study, UPLC-ESI-MS/MS with multiple reaction monitoring (MRM) was employed to screen urinary phospholipid (PL) content for biomarkers of prostate cancer. From lists of urinary PLs structurally identified using nanoflow LC-ESI-MS/MS, 52 PL species were selected for quantitative analysis in urine samples between 22 cancer-free urologic patients as controls and 45 prostate cancer patients. Statistical treatment of data by receiver operating characteristic (ROC) analysis yielded 14 PL species that differed significantly in relative concentrations (area under curve (AUC) > 0.8) between the two groups. Among PLs present at higher levels in prostate cancer urine, phosphatidylcholines (PCs) and phosphatidylinositols (PIs) constituted the major head group PLs (3 PCs and 7 PIs). For technical reasons, PL species of low abundance may be underrepresented in data from UPLC-ESI-MS/MS performed in MRM mode. However, the proposed method enables the rapid screening of large numbers of plasma or urine samples in the search for biomarkers of human disease.

Comparison of Anthocyanin Content in Seed Coats of Black Soybean [Glycine max(L.) Merr.] Cultivars Using Liquid Chromatography Coupled to Tandem Mass Spectrometry

  • Shin, Sung-Chul;Lee, Soo-Jung;Lee, Sung-Joong;Chung, Jong-Il;Bae, Dong-Won;Kim, Soo-Taek;Sung, Nak-Ju
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1470-1475
    • /
    • 2009
  • The seed coat of the black soybean contains 3 main anthocyanins such as delphinidin-3-O-$\beta$-glucoside, cyanidin-3-O-$\beta$-glucoside, and petunidin-3-O-$\beta$-glucoside. As a part of our effort on discovering and breeding new black soybean cultivars which possesses specific anthocyanin component rich, we determined the anthocyanin profiles of the 2 cultivars recently developed soybean cv. Gaechuck #1 and cv. Gyeongsang #1, using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and compared their content and identity with those of previously known 10 cultivar controls. The Cosmosil-$5C_{18}$-AR-II column were selected for the analysis because of the best peak separation. The column temperature was set up at $35^{\circ}C$. The mobile phase consisting of water containing 0.5%(v/v) formic acid and methanol gave good separation between the 3 anthocyanin analytes and internal standard (quercetin 3-O-$\beta$-rutinoside) and peaks with suppressed tail. The MS/MS spectra of each individual anthocyanin standard were detected in positive electron spray ionization (ESI) modes. It was disclosed that the anthocyanin contents of the soybean cv. Gaechuck#1 and cv. Gyeongsang#1 are roughly higher than those of the 10 controls.