• Title/Summary/Keyword: ESAF

Search Result 3, Processing Time 0.014 seconds

A Study on the Impact Sensing Device for Improving the Firing Function Reliability of ESAF (ESAF의 기폭 신뢰성 향상을 위한 충격감지장치 연구)

  • Jo, Seyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.525-531
    • /
    • 2015
  • In this paper, a novel impact sensing device for an ESAF(Electronic Safe and Arming Fuze) is presented. An impact sensing device is mounted in front of a weapon, and it detects an impact when it crashes against a target. There are two main design requirements to enhance the firing functional reliability of the ESAF; an operational reliability and a reduced latency, which is a delay time needed for sensing the impact. The design method of the contact-type impact sensing device, which employs an FPCB(Flexible Printed Circuit Board) so it can be used other weapons, is proposed. The tests demonstrated that the design described in this work show a reduced delay time with ensuring the operational reliability.

Atrial Fibrillation Waveform Extraction Algorithm for Holter Systems (홀터 심전계를 위한 심방세동 신호 추출 알고리즘)

  • Lee, Jeon;Song, Mi-Hye;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.38-46
    • /
    • 2012
  • Atrial fibrillation is needed to be detected at paroxysmal stage and to be treated. But, paroxysmal atrial fibrillation ECG is hardly obtained with 12-lead electrocardiographs but Holter systems. Presently, the averaged beat subtraction(ABS) method is solely used to estimate atrial fibrillatory waves even with somewhat large residual error. As an alternative, in this study, we suggested an ESAF(event-synchronous adaptive filter) based algorithm, in which the AF ECG was treated as a primary input and event-synchronous impulse train(ESIT) as a reference. And, ESIT was generated so to be synchronized with the ventricular activity by detecting QRS complex. We tested proposed algorithm with simulated AF ECGs and real AF ECGs. As results, even with low computational cost, this ESAF based algorithm showed better performance than the ABS method and comparable performance to algorithm based on PCA(principal component analysis) or SVD(singular value decomposition). We also proposed an expanded version of ESAF for some AF ECGs with multi-morphologic ventricular activities and this also showed reasonable performance. Ultimately, with Holter systems including our proposed algorithm, atrial activity signal can be precisely estimated in real-time so that it will be possible to calculate atrial fibrillatory rate and to evaluate the effect of anti-arrhythmic drugs.

Isolation and Characterization of Three Zygomycetous Fungi in Korea: Backusella circina, Circinella muscae, and Mucor ramosissimus

  • Nguyen, Thuong T.T.;Lee, Hyang Burm
    • Mycobiology
    • /
    • v.46 no.4
    • /
    • pp.317-327
    • /
    • 2018
  • While surveying undiscovered fungal taxa in Korea, three rare zygomycetous fungal strains, CNUFC-PTF2-1, CNUFC-TF3-1, and CNUFC-ESAF3-1, were isolated from soil, leaf, and freshwater samples, respectively. The strains were analyzed morphologically as well as phylogenetically based on the internal transcribed spacer region and 28S rDNA sequences. Sequence analysis of the two loci revealed that the isolates, CNUFC-PTF2-1, CNUFC-TF3-1, and CNUFC-ESAF3-1, were identified as Backusella circina, Circinella muscae, and Mucor ramosissimus, respectively. These species have not yet been previously described in Korea.