• 제목/요약/키워드: EPS density

검색결과 52건 처리시간 0.022초

태풍 진로예측을 위한 다중모델 선택 컨센서스 기법 개발 (Development of the Selected Multi-model Consensus Technique for the Tropical Cyclone Track Forecast in the Western North Pacific)

  • 전상희;이우정;강기룡;윤원태
    • 대기
    • /
    • 제25권2호
    • /
    • pp.375-387
    • /
    • 2015
  • A Selected Multi-model CONsensus (SMCON) technique was developed and verified for the tropical cyclone track forecast in the western North Pacific. The SMCON forecasts were produced by averaging numerical model forecasts showing low 70% latest 6 h prediction errors among 21 models. In the homogeneous comparison for 54 tropical cyclones in 2013 and 2014, the SMCON improvement rate was higher than the other forecasts such as the Non-Selected Multi-model CONsensus (NSMCON) and other numerical models (i.e., GDAPS, GEPS, GFS, HWRF, ECMWF, ECMWF_H, ECMWF_EPS, JGSM, TEPS). However, the SMCON showed lower or similar improvement rate than a few forecasts including ECMWF_EPS forecasts at 96 h in 2013 and at 72 h in 2014 and the TEPS forecast at 120 h in 2013. Mean track errors of the SMCON for two year were smaller than the NSMCON and these differences were 0.4, 1.2, 5.9, 12.9, 8.2 km at 24-, 48-, 72-, 96-, 120-h respectively. The SMCON error distributions showed smaller central tendency than the NSMCON's except 72-, 96-h forecasts in 2013. Similarly, the density for smaller track errors of the SMCON was higher than the NSMCON's except at 72-, 96-h forecast in 2013 in the kernel density estimation analysis. In addition, the NSMCON has lager range of errors above the third quantile and larger standard deviation than the SMCON's at 72-, 96-h forecasts in 2013. Also, the SMCON showed smaller bias than ECMWF_H for the cross track bias. Thus, we concluded that the SMCON could provide more reliable information on the tropical cyclone track forecast by reflecting the real-time performance of the numerical models.

EC-MBR에서 전기응집이 슬러지 특성에 미치는 영향 (Effect of electrocoagulation on sludge characteristics in EC-MBR)

  • 엄세은;장인성
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.42-49
    • /
    • 2017
  • 전기응집 공정은 MBR (Membrane Bio-Reactor) 공정의 막 오염을 해결하기 위한 일환으로 응용되고 있다. 본 연구는 전기응집 공정의 중요한 운전변수인 전류밀도와 접촉시간에 따른 활성슬러지의 특성 변화에 관한 연구를 수행하였다. 전류밀도를 2.5, 12, $24A/m^2$로, 접촉시간은 0, 2, 6 hr로 변화시켜 가며 활성슬러지의 특성 변화를 관찰하였다. 전류밀도 $24A/m^2$ 조건에서 6시간 동안 MLSS는 6,800에서 7,000 mg/L로 3% 증가하였고, MLVSS는 6,280에서 6,300 mg/L로 큰 변화가 없었다. 다른 전류밀도 조건 하에서도 동일한 경향이 관찰되었다. COD는 전류밀도가 $24A/m^2$일 때 71에서 37 mg/L로 감소하였고, $12A/m^2$일 때는 113에서 67 mg/L로, $2.5A/m^2$일 때는 84에서 80 mg/L로 감소하였다. 반면 TN과 TP는 전반적으로 큰 변화를 보이지 않았다. Soluble-EPS와 Bound-EPS는 전류밀도가 증가할수록 약간 감소하는 경향을 보였다. 전기응집을 거친 활성슬러지로 막 여과를 수행하여 여과성능이 개선되는지 평가하였다. 전기응집을 수행하지 않은 대조군에 비해 총여과저항 ($R_t$)이 6~61% 감소한 것으로 나타났다. 특히 전류밀도와 접촉시간이 증가할수록 막 여과 저항이 감소하는 것을 확인하였다. 이를 통해 전기응집 공정이 MBR 공정의 막 여과 성능 개선에 사용될 수 있음을 확인하였다.

가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method)

  • 심지훈;이재걸;한경호;김주완;송석훈;조형원;윤도영
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.519-524
    • /
    • 2022
  • 국내 건축물 마감재는 국토교통부 고시에 따라 KS F 2271 기준에 의해 평가되어지고 있으며, 이 실험은 실험동물을 사용하여 평가하고 있다. 본 연구에서는 가연성이 높은 유기물 단열재 EPS, 우레탄, 페놀폼에 대해 실험을 진행하였다. 이 3종의 단열재가 연소 시 발생되는 유해성 가스에 의한 실험용 쥐의 평균행동정지시간을 측정하여, 실험용 쥐의 행동정지에 대한 원인을 분석하고자 하였다. 실험용 쥐의 행동정지에 대한 원인분석방법으로는 FTIR 분석과 연기밀도실험을 진행하였고, 마우스의 행동정지 원인을 입자상물질에 의한 질식과 가스상물질에 의한 독성흡입으로 구분하여 실험결과를 분석하였다. 실험결과 우레탄이 가장 유해한 단열재로 평가되었으며, 가스유해성 실험결과에 대한 원인분석으로 FTIR분석과 연기밀도 실험을 진행한 결과, 독성흡입에 의한 영향보다 질식에 의한 실험용 쥐의 행동정지가 높은 것으로 나타났다. 본 연구는 유해성가스의 원인분석에 대한 기초연구로서, 독성의 근거를 마련하고 나아가 다양한 재료와 가스에 대한 분석을 통하여 보다 구체적인 독성평가의 기준이 마련될 수 있을 것으로 기대된다.

전기분해를 이용한 하수슬러지 가용화 연구 (The Study on the Solubilization of Sewage Sludge by Electrolysis Treatment)

  • 김재형;전혜연;이준철;박대원
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.194-201
    • /
    • 2012
  • 본 연구에서는 소화가스 효율 향상을 위한 전처리로 전기분해를 이용한 하수슬러지 가용화 연구를 수행하였다. 전기분해 처리시간과 전류밀도가 증가함에 따라 SCOD 농도가 증가하였고, 처리시간 60분에 SCOD, TN, TP가 각각 7.4배, 1.9배, 1.3배로 가장 높은 증가율을 보였다. 하수슬러지 초기 pH별 전기분해 처리효과는 강산성, 강알칼리성에서 가용화율이 높았고, 특히 pH 12에서 32.9%의 높은 가용화율을 보였다. 이상의 결과는 전기분해에 의한 직 간접산화작용으로 인해 슬러지의 플록, EPS 구조가 파괴되어 미생물이 이용가능한 유기물들이 증가되었음을 의미한다.

마감모르타르 물결합재비에 따른 바닥충격음 특성 변화 (Characteristics of the floor impact sound by water to binder ratio of mortar)

  • 이원학;한찬훈
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.671-677
    • /
    • 2021
  • 본 연구의 목적은 마감모르타르의 물결합재비가 공동주택 바닥충격음에 미치는 영향을 조사하는 것이다. 이를 위하여 동일한 동탄성계수를 지닌 Expanded Polystyrene(EPS) 완충재와 52 %, 66 %, 72 % 의 물결합재비를 가진 모르타르를 활용하여 뜬바닥구조를 시공하였으며, 표준실험동에서 바닥충격음을 측정하였다. 실험결과, 경량충격음에 있어서는 물결합재비 52 % 일 때, 밀도가 높은 관계로 경량충격음 전달특성이 높게 나타났다. 마감모르타르의 물결합재비가 높아지면 완충재 상부층 질량이 낮아지고, 이로 인해 뜬바닥구조의 고유진동수가 63 Hz 대역으로 이동하게 되면서 중량충격음의 음압레벨이 높게 나타났다. 이를 통하여 마감모르타르의 물결합재비가 중량충격음에 미치는 특성을 규명하였다.

고밀도 EPS를 이용한 돔 구조 안전성에 대한 고찰 (Dome Structure using High-Density EPS Review of Safety)

  • 장석준;이동운
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.119-120
    • /
    • 2011
  • Dome structure to form a space-efficient, applied a lot of beautiful buildings with structural systems, as well as a large space structure in the form of new residential lots have been applied. And domestic demand for housing in the dome with increasing dome house using various materials, are becoming commonplace. But now the Dome House is mainly used in construction steel, wood, stone, FRP construction and building materials per unit area and the high cost, long construction time, energy efficiency, has some disadvantages such as degradation. And structural strength of the structure is weak, the natural ingredients used come from natural damage is so big. In addition, demolition of buildings in trouble when handling the environmental problems has emerged. Recently expanded polystyrene to improve these problems by using the various approaches and research is being attempted and there.

  • PDF

박테리아의 Quorum Sensing 및 생물막 형성 억제를 위한 Quorum Quenching 연구 동향 (Bacterial Quorum Sensing and Quorum Quenching for the Inhibition of Biofilm Formation)

  • 이정기
    • 한국미생물·생명공학회지
    • /
    • 제40권2호
    • /
    • pp.83-91
    • /
    • 2012
  • 본 총설은 N-acyl-homoserine lactone (AHL)에 기반한 quorum sensing(QS)을 비롯한 다양한 QS 시스템 및 생물막 형성과의 관련성에 대한 연구 동향을 정리하였다. 또한 anti-QS으로서 quorum quenching 전략을 이용한 생물막 억제 연구 동향에 대해 중점적으로 서술하였다. 세균의 독특한 신호전달 체계인 QS는 AHL과 같은 특정한 신호분자의 농도에 의해 세균의 집단적 행동 양식이 결정되는 세포밀도-의존성 유전자 발현 조절 메커니즘이다. QS 시스템은 미생물의 부착 및 생물막 형성에 있어 중요한 역할을 한다. AI-1이나 AI-2에 의한 QS는 생물막 형성 과정에 필요한 세포외 다당류, 단백질, 세포 외 DNA 등 주요한 구성 성분 등의 생산뿐만 아니라, 세균의 운동성 조절, 부착, 생물막 해체 과정까지도 조절하는 기능을 한다. 일부 세균의 경우 QS시스템 이외에도 second messenger로 알려진 c-di-GMP에 의한 signaling이 QS와 서로 연결되어 생물막 형성이나 병독성과 같은 타깃들을 함께 조절한다. 생물막은 병원성 세균에 의한 감염 시 여러 가지 병독성 가운데 가장 중요한 요소 중 하나이기 때문에, 생물막 형성을 조절하는 QS를 차단하기 위한 다양한 anti-quorum sensing 전략이 연구되고 있다. Anti-QS 접근 방식은 의학적 이용뿐만 아니라 물에 노출되어있는 MBR을 비롯한 많은 산업적 장치 등에서 생물막 형성으로 인한 손상 및 오염을 방지하기 위해 쓰일 수 있다. Anti-QS 전략 중 신호분자인 AHL을 무력화 시키는 quorum quenching 효소(AHL-lactonase, AHL-acylase, oxidoreductas)를 이용하여 생물막 형성을 억제할 수 있으며, 막을 이용한 수처리 공정에서 막에 발생하는 biofouling을 완화시킬 수 있는 새로운 anti-fouling 처리 기술로서 이러한 QQ 효소의적용 가능성을 보여 주고 있다.

A Feasibility Study on the Formation of the Permeable Reactive Biobarier treated with Beijerinckia indica

  • Lim, Dong-Hee;Lee, Jai-Young
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.75-78
    • /
    • 2001
  • Authors evaluated the feasibility of a permeable reactive biobarrier (PRB) treated with biofilm formed by Beijerinckia indica (B.indica). This study focused on evaluating two potentials of B.indica for the requirements of PRB: reducing the hydraulic conductivity and degrading the polycyclic aromatic hydrocarbons (PAHs). The hydraulic conductivity was estimated by rigid wall column test and finally the values were converted to the values of intrinsic permeability. The nutrient solution was passed through the biobarrier column to activate the bacterium and then leachate was in turn carried into the column to evaluate the durability of the biobarrier. Phenanthrene was selected as a representative substance of PAHs. The ability of degrading phenanthrene by B.indica was evaluated by two-phase partitioning bioreactor after estimating the possibility with two pretests: observing the colony formation and the optical density on glucose-free medium containing phenanthrene. With the results, B.indica produced large amount of strongly adhesive exopolysaccharides (EPS) and reduced several orders of magnitude of the hydraulic conductivity after 2 weeks of cultivation. Furthermore, about 1000mg/1 of phenanthrene could be degraded by B.indica in the two-phase partitioning bioreactor. In conclusion, the application of the bacterium, B.indica, was found to have a potential role of a PRB to retain and remove contaminants in porous media.

  • PDF

유기질 단열재 장기 흡수율에 관한 연구 (A Study on the Long-term Absorption Rate of Organic Insulation Materials)

  • 김해나;박준서;신종현;홍상훈;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.195-196
    • /
    • 2022
  • Insulation material absorption rate is closely related to thermal conductivity. In Korea, there is no study on the change of insulation material in a long-term continuous exposure environment. In this study, basic data on the long-term durability of insulation materials were obtained by measuring the absorption rate of insulation materials over time. For the purpose of providing, as a result of the measurement, PIR class2 No.2 and PIR noncombustible show similar absorption rate trends, which is thought to be due to the fact that both are made of rigid urethane foam, and flame retardant EPS has the highest absorption rate except for PF. This is thought to be because there is a space for absorption between the beads and the beads. In the case of XPS, it is thought that the reason for showing the lowest absorption rate is that because it is produced by extrusion, it has a high density and thus has less space for moisture to penetrate.

  • PDF

그린리모델링 성과 평가 관점에서 본 준공 시점 단열 성능 검증의 중요성 (Importance of Preliminary Validation of Exterior Wall Thermal Resistance in the Evaluation Context of Building Energy Retrofit Projects)

  • 임승민;김소연;강창오;김가인;임종연
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.29-37
    • /
    • 2024
  • 본 논문에서는 공공건축물 그린리모델링 과정에서 철거되는 단열재 샘플을 수거하여 열전도율과 밀도 등 단열성능과 관련된 물성치에 대한 측정 결과를 제시하였다. 단열재의 장기 열저항은 제조 초기 단계의 열전도율을 추정하기 위한 자료가 남아있지 않다는 한계로 인해 정확한 변화 양상을 도출하기 어려웠지만, 설계도서를 통해 추정한 정보에 기반하여 비드법 단열재의 경우 기존 지식과 동일하게 설치 후 10년 이상 경과 시 성능변화가 크지 않다는 결과를 얻을 수 있었다. 하지만 동일 등급, 동일 경과 기간의 단열재에서 측정된 열전도율의 편차가 크고, 특히 단열재 샘플의 밀도가 설계도서상에 기재된 설치 단열재의 등급 기준에 크게 못 미친다는 결과를 얻었다. 준공 시점 및 운영 단계의 성능 관리가 되지 않고 있다는 것을 보여주는 실험 결과이며, 그린리모델링 등 건축물에너지 성능 개선을 적절히 평가하기 위해서는 건물생애주기에 걸친 성능 검증인 빌딩커미셔닝의 적용이 중요하다.