• Title/Summary/Keyword: EPRI

Search Result 167, Processing Time 0.033 seconds

Probabilistic Reliability Analysis of KEPCO System Using TRELSS

  • Tran Trung Tinh;Kwon Jung-Ji;Choi Jae-Seok;Choo Jin-Boo;Jeon Dong-Hun;Han Kyoeng-Nam;Billinton Roy
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.10-18
    • /
    • 2007
  • The importance of conducting necessary studies on grid reliability evaluation has become increasingly important in recent years due to the number of blackout events occurring throughout the world. Additionally, quantitative evaluation of transmission system reliability is very important in a competitive electricity environment. The reason behind this is that successful operation of an electric power company under a deregulated electricity market depends on transmission system reliability management. The results of many case studies for the Korea Electric Power Cooperation (KEPCO) system using the Transmission Reliability Evaluation for Large-Scale Systems (TRELSS) Version 6.2 are illustrated in this paper. The TRELSS was developed by EPRI and Southern Company Services Inc. This paper presents the reliability analysis of KEPCO system expansion planning by using the TRELSS program.

A Study on Development of Value-added Service Application for ESP based on Consumer Portal System (수용가 포탈 시스템 기반의 전력부가서비스 개발에 관한 연구)

  • Yang, Won-Chul;Kim, Jae-Hee;Kim, Sang-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.653-656
    • /
    • 2006
  • 선진 전력시장에서는 전력산업의 환경이 수용가 중심의 시장구조로 변화함에 따라, 이들을 대상으로하여 IT 기반의 다양한 전력부가서비스가 제공되고 있다. 이러한 서비스에 대한 연구개발은, 시간이 흐르면서 단방향이 아닌 양방향 통신 기반의 소비자 중심 서비스 분야로 확대되는 경향을 보인다. 특히, 미국 EPRI의 IntelliGrid 컨소시엄에서 제시한 수용가 포탈은 소비자 영역내의 장비와 에너지 서비스 기관 간의 양방향 통신을 지원하는 통합적인 개념의 서비스 기반으로, ESP(Energy Service Provider)와 소비자는 더욱 상세한 정보를 이용하여 더 많은 이익과 혜택을 기대할 수 있다. 이에 비해 국내의 전력부가서비스 제공 수준은 아직 시작 단계에 불과하지만, 머지않아 국내 전력시장 역시 양방향 통신 기반의 수준 높은 전력부가서비스를 요구하게 될 것으로 보인다. 따라서 국내환경에 적합한 수용가 포탈 기반의 전력부가서비스 개발이 필요하며 이를 통해 수용가에게는 비용 절감이 가능한 합리적인 소비 방안을 제시하고, ESP에게는 부하 수요관리 및 투자비를 절감할 수 있는 기회를 제공해야 할 것이다. 본 논문에서는 새로운 전력부가서비스를 기반이 될 수용가 포탈을 분석하고, 현행 전력부가서비스의 현황과 동향 분석, 적용가능 기술 분석을 수행하여 그 결과를 바탕으로 국내환경에 적합한 수용가 포탈시스템 기반의 전력부가서비스 선정 및 구축 방안을 제시하고자 한다.

  • PDF

The feasibility study of the application of PRA(probabilistic reliability assessment) at the practical operational planning task (계통운영분야에 확률론적 신뢰도 평가 적용 가능성에 관한 연구)

  • Choi, H.S.;Song, T.Y.;Rju, H.K.;Jeon, D.H.;Kyak, N.H.;Choi, J.S.;Jeong, S.H.;Kwon, J.J.;Park, J.J.;Yoon, Y.T.;Lee, H.C.;Cha, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.50-51
    • /
    • 2007
  • 과거 단일 회사로 구성된 전력산업 체제하에서의 신뢰도에 대한 인식과 중요성들이 전력시장과 경쟁이 도입된 다각화된 이해 주체들 이 존재하는 현행의 국내 전력산업 구조에서는 서로 다른 양상을 띄고 변화하고 있다. 전원 및 송?변전 시설계획에서부터 계통운영 계획 및 실시간 급전에 이르기까지 연속선상의 계통운영 업무에 있어 전력공급의 안정성 확보와 더불어 보다 합리적이고 효율적인 또는 경제적인 계획과 운영에 대한 요구(Needs)가 기존의 결정론적인 신뢰도 평가의 다각적 접근 즉, 확률론적인 신뢰도평가 기법을 개발하게 하였으며, 이에 미국 전력중앙연구소(EPRI)의 PRA(Probabilistic Reliability Assessment) S/W를 도입하여 실제 계통운영의 단위업무와 접목하여 리스크를 고려한 계통안전도평가 구현의 잠재적 가능성과 극복해야 할 한계를 파악하였다.

  • PDF

Area Annual Outage Cost Assessment of KEPCO System by TRELSS (TRELSS를 이용한 KEPCO 계통의 공급지장비 추정연구)

  • Shi, Bo;Jeong, S.H.;Park, J.J.;Choi, J.S.;Jeon, D.H.;Yun, Y.B.;Jang, B.H.;Moon, S.P.;Han, K.N.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.578-579
    • /
    • 2007
  • The importance and necessity of conducting studies on area outage cost assessment have been increasingly important in recent years due to the competitive electricity market environment. The objective of operational issues would be to minimize the total area cost while satisfying all associated system constrains of each area[2]. This paper presents a methodology of the Area annual outage cost assessment by probabilistic reliability evaluation using TRELSS program for KEPCO system. The interrupted energy assessment rate (IEAR) is evaluated by macro approach that is using relations between GRDP and the electrical energy demand. The Expected Energy Not Supplied (EENS) of each area was evaluated using the Transmission Reliability Evaluation for Large-Scale Systems (TRELSS) Version 6_2, a program developed by EPRI are introduced in this paper.

  • PDF

A Study on Intelligent Grid R&D Programs (Intelligent Grid 연구개발 프로그램 조사 연구)

  • Jung, Nam-Joon;Yang, Il-Kwon;Oh, Do-Eun;Yu, In-Hyeob
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.798-799
    • /
    • 2007
  • 전력 및 IT기술의 발달은 사전에 전력 문제를 예측하고 조치할 수 '지능적인 전기 그리드'의 생성을 가능하게 하였다. 이러한 'Intelligent Grid'는 전력 산업의 신뢰도 및 고객 서비스 측면에서 에너지 공급자들의 성장을 가능하게 했다고 할 수 있겠다. 최근 많은 새로운 연구개발 프로그램들은 전력 기반시설의 지능화를 향상시키는 목표를 가지고 구성되고 있다. 이미 설립된 다른 R&D 조직과 더불어 이러한 프로그램들은 더욱 지능화된 그리드를 만드는데 있어서 기술적, 경제적, 그리고 정책적인 장벽을 호소하고 있다. 그러나 이러한 풍부한 연구 활동은 그리드 사업이 진정으로 완성 될 수 있다고 생각하는 산업관계자들에게는 더욱 자신감을 심어주고 있는 상황이다. 동시에 이러한 유틸리티, 제조사, 표준화 기구 그리고 공공 기관과 같은 관계자들은 연구기관들이 제안하는 도전에 대하여 다양한 연구 프로그램들을 어떻게 구별하고 또한 어떻게 결과를 이해해야 할지 등에 관하여 고민하고 있다. 다양한 프로그램에 대한 노력과 결과의 명쾌한 그림을 찾고 있으며, 프로그램들 사이의 더 높은 수준의 협력을 요청하고 있다. 본 논문에서는 다양한 'Intelligent Grid' 프로그램을 간단히 소개하고 협력을 위한 EPRI의 노력에 대하여 소개하고자 한다.

  • PDF

A Study on the Feasibility Analysis and Capacity Estimation of BESS for Self-Starting Generators (자체기동발전원으로서 BESS의 활용가능성 분석 및 용량 산정에 관한 연구)

  • Kim, Cha-Nyeon;Yu, Won-Kun;kim, Heon-Tae;Lee, Heung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1119-1124
    • /
    • 2018
  • So far BESS(Battery Energy storage system) has been widely applied to power systems rapidly. Usually it has been used to regulate the renewable energy output and to adjust the power system frequency. In 2013, EPRI has reported a study of utilizing BESS to replace two black start generators of American Electric Power(AEP) that will be demolished. If the BESS can be used as a self-starting generator, it is possible to shorten the long-distance primary transmission line and shorten the restoration time because BESS is capable of the high-speed start and there is no restriction on the installation position. This paper presents a possibility of using BESS as a self-starting generator by using PSCAD/EMTDC in Korean power systems. Herein, the process to estimated the required capacity of BESS is also presented.

A Study on Application of PRA for Korea Power System in Planning Mode (계통계획측면에서의 우리나라 전력계통에 대한 PRA활용연구)

  • Jeong, S.H.;Kwon, J.J.;Shi, Bo;Park, J.J.;Choi, J.S.;Yoon, Y.T.;Lee, H.C.;Cha, J.M.;Jeon, D.H.;Choi, H.S.;Song, T.Y.;Rju, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.3-4
    • /
    • 2007
  • 본 논문은 전력계통의 보다 합리적인 신뢰도 운영을 실시하고자 근래 V&R Energy System Research에서 개발한 신뢰도 평가 프로그램인 POM과 EPRI에서 개발한 PRA를 이용하여 우리나라계통에 적용하여 성공적으로 얻은 다양한 사례연구 결과를 소개한다. 여기서는 PRA 프로그램을 우리나라 전력계통의 계획측면에서 활용방안을 모색하기로 하고 다음과 같은 몇 가지 사례연구에 주안점을 두고 실시하였다. 2008년도 우리나라 계통의 병입되는 당진화력 7,8호기의 신설에 따란 계통영향에 대한 신뢰도 지수 비교 순석과 2007년부터 2012년까지의 향후 6년간에 걸친 장기계통계획에 대한 우리나라계통의 신뢰도 지수의 변화를 비교 분석하는 등 계통계획측면에서의 활용방안의 타당성에 관하여 검토하였다.

  • PDF

An Investigation on the Environmental Effect of the Magnetic Field due to Overhead Transmission Line (가공송전선로에 의한 자계환경영향 검토 및 수동루프에 의한 자계저감효과 검토)

  • Jeong, Seung-Yong;Lim, Yun-Sok;Lee, Sang-Wha;Koo, Ja-Yoon;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.116-118
    • /
    • 2004
  • 송전선로 주변의 전자계 노출은 소아들의 암 발생/사망과 성인의 암 등 여러 가지 질병 발생 가능성이 항상 있으므로 전자계 노출을 장기간 계속적으로 받고 있는 환경을 관찰하는 것이 가장 중요하다. 따라서 본 연구에서는 이에 대한 연구기반을 형성하기 위해 송전 선로의 모델과 현장 실측을 통해 송전선로 자계치를 계산하여 시뮬레이션 하고자한다. 시뮬레이션을 통해 산출된 자계치를 이용하여 최근 효과적인 자계 저감책으로 보고되고 있는 수동루프에 의한 자계저감효과를 검토하고자 한다. 입력된 데이터는 765kV 실 송전선로를 모델로 사용하였으며, 자계의 계산 및 수동 루프에 의한 자계 저감 효과를 알아보기 위해서 미국 EPRI에서 개발한 자계 계산 전용 프로그램인 EMF Modeler를 이용하였다. 먼저 송전선로에 의해 발생되는 자계의 원리를 서술하였으며, 수동 루프를 통한 자계 감소 정도를 수식으로 유도하였고, EMF Modeler를 통하여 송전선 주변의 자계 분포 및 수동루프에 의한 자계 저감 효과를 각각 확인하였다.

  • PDF

On the Reconstruction of Pinwise Flux Distribution Using Several Types of Boundary Conditions

  • Park, C. J.;Kim, Y. H.;N. Z. Cho
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.311-319
    • /
    • 1996
  • We reconstruct the assembly pinwise flux using several types of boundary conditions and confirm that the reconstructed fluxes are the same with the reference flux if the boundary condition is exact. We test EPRI-9R benchmark problem with four boundary conditions, such as Dirichlet boundary condition, Neumann boundary condition, homogeneous mixed boundary condition (albedo type), and inhomogeneous mixed boundary condition. We also test reconstruction of the pinwise flux from nodal values, specifically from the AFEN [1, 2] results. From the nodal flux distribution we obtain surface flux and surface current distributions, which can be used to construct various types of boundary conditions. The result show that the Neumann boundary condition cannot be used for iterative schemes because of its ill-conditioning problem and that the other three boundary conditions give similar accuracy. The Dirichlet boundary condition requires the shortest computing time. The inhomogeneous mixed boundary condition requires only slightly longer computing time than the Dirichlet boundary condition, so that it could also be an alternative. In contrast to the fixed-source type problem resulting from the Dirichlet, Neumann, inhomogeneous mixed boundary conditions, the homogeneous mixed boundary condition constitutes an eigenvalue problem and requires longest computing time among the three (Dirichlet, inhomogeneous mixed, homogeneous mixed) boundary condition problems.

  • PDF

Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment (기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가)

  • Park, Junhee;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2015
  • There are a lot of equipment related to safety and electric power production in nuclear power plants. The structure and equipment in NPPs were generally designed considering a high safety factor to remain in the elastic zone under earthquake load. However it is needed to revaluate the seismic capacity of the structure and equipment as the magnitude of earthquake was recently increased. In this study the floor response due to the nonlinear behaviors of structure was analyzed and the inelastic structural response factor was calculated by the nonlinear time history analysis. The inelastic structural response factor was calculated by the EPRI method and the nonlinear analysis method to realistically evaluate the seismic fragility for the equipment. According to the analysis result, it was represented that the inelastic structural response factor was affected by the natural frequency of equipment, the location of equipment and the dynamic property of structure.