Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog (SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석)

  • 박재준;양태규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.500-504
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and .am) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonir waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging (코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Youn, Bok-Hee;An, Jong-Sik;Lee, Sang-Yong;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

UV Aging on EPDM rubber for use in polymer Insulators (폴리머 애자용 EPDM 고무의 자외선 열화특성)

  • Youn, Bok-Hee;Lee, Sang-Yong;An, Jong-Sik;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.62-65
    • /
    • 2001
  • The effects of accelerated UV radiation on EPDM used for a polymeric insulator were investigated by contact angle, surface voltage decay after corona charging, SEM-EDX, ATR-FTIR and XPS. EPDM occurs as loss of hydrophobicity by UV treatment, which followed by surface cracking and chalking. The surface voltage decay on UV-treated EPDM show that the shorter decay time corresponded to the treated samples with a longer UV exposure time. The surface oxygen and aluminum content were found to increase and carbon decrease, as is observed in EDX analysis. The ATR-FTIR and XPS indicated that C-C and C-H groups decreased and the highly oxidized carbon bonds such as C-O, C=O and O-C=O increase with time. Also, the effects of surface charges on hydrophobicity based on our results is discussed.

  • PDF

A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents (Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성)

  • ark, Jae-.Jun;Song, Il-keun;Lee, Jae-bong;Chun, Sung-nam
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation (인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성)

  • Kim, Y.S.;Choi, M.I.;Kim, C.M.;Bang, S.B.;Shong, K.M.;Kwag, D.S.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

The Study for the Breakdown Characteristics of Interface between LSR-XLPE, EPDM-XLPE by the Interfacial Treatment Condition (LSR-XLPE, EPDM-XLPE 이종계면에서의 계면처리에 따른 절연파괴특성)

  • Cho, Han-Goo;Lee, Yu-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.460-461
    • /
    • 2007
  • In this paper, we studied the properties of a cable insulate capacity between surfaces with the variation of the interfacial breakdown. As a function of silicon oil, the variation of pressure and interfacial roughness were investigated. The insulate trouble of a power cable is out of the interfacial parts, which breakdown the insulate breakdown capacity in a power cable. In this study, the analysis of electric field and the phenomenon of interfacial breakdown were improved by increased interfacial pressure, decreased surface roughness, and oil. And It was shown that interfacial breakdown LSR-XLPE insulators is higher that of EPDM-XLPE.

  • PDF

A Review of the Flashover Performance of High Voltage Insulators Constructed with Modern Insulating Materials

  • Khatoon, Shabana;Khan, Asfar Ali;Singh, Sakshi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.246-249
    • /
    • 2017
  • Pollution flashover of outdoor insulators is a common risk, which affects the safe operation of overhead transmission networks. Early electrical power systems, which feature insulators made from ceramic materials have been used all over the world with good performance. At present, non-ceramic insulators are in common use, as a result of their good electrical as well as mechanical properties. The aim of this paper is to discuss and compare the flashover performance of insulators typically used in power lines, such as, porcelain, ethylene-propylene-diene-monomer (EPDM) rubber, room temperature vulcanized (RTV) and high temperature vulcanized (HTV) coated silicone rubber. The effect of various parameters, including the severity of pollution, ice accumulation, and shade profile, are considered.. From the studies reviewed it was concluded that there is a distinct difference in the flashover voltages of different types of insulators, and the silicone provides the best flashover performance of all insulating materials.

Dielectric Characteristics due to Variation of Temperature at Interface of Composite Insulators (복합절연체 계면에서의 온도변화에 따른 유전정접 특성)

  • Park, Hee-Doo;An, Byung-Chul;Kim, Tag-Yong;Shin, Jong-Yeol;Kim, Gui-Yeol;Lee, Chun-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.132-133
    • /
    • 2005
  • 고분자 절연재료의 혼합사용을 통한 계면의 전기적 특성 및 온도 특성을 조사하기 위하여 XLPE층 과 EPDM 층을 각각 단일층 및 이중층으로 적층하였으며, 온도는 상온에서 100 [$^{\circ}C$]까지 변환시키면서 유전정접을 측정하였다. 또한 data는 LABview를 이용하여 GPIB통신으로 받아들인 값을 평균치를 구하여 컴퓨터에 저장하였다. 측정결과 온도에 무관하게 이층구조는 단일층 사이의 값을 나타내며, 온도증가에 따라 XLPE 단일층의 변화가 크게 나타났으며, 이중층은 EPDM의 변화에 크게 의존함을 확인할 수 있었다.

  • PDF

A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials (옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Kim, Yeong-Seong;Jeong, Sun-Ok
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.