• Title/Summary/Keyword: ENERGY-10

Search Result 46,987, Processing Time 0.063 seconds

Fuzzy Logic based Admission Control for On-grid Energy Saving in Hybrid Energy Powered Cellular Networks

  • Wang, Heng;Tang, Chaowei;Zhao, Zhenzhen;Tang, Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.10
    • /
    • pp.4724-4747
    • /
    • 2016
  • To efficiently reduce on-grid energy consumption, the admission control algorithm in the hybrid energy powered cellular network (HybE-Net) with base stations (BSs) powered by on-grid energy and solar energy is studied. In HybE-Net, the fluctuation of solar energy harvesting and energy consumption may result in the imbalance of solar energy utilization among BSs, i.e., some BSs may be surplus in solar energy, while others may maintain operation with on-grid energy supply. Obviously, it makes solar energy not completely useable, and on-grid energy cannot be reduced at capacity. Thus, how to control user admission to improve solar energy utilization and to reduce on-grid energy consumption is a great challenge. Motivated by this, we first model the energy flow behavior by using stochastic queue model, and dynamic energy characteristics are analyzed mathematically. Then, fuzzy logic based admission control algorithm is proposed, which comprehensively considers admission judgment parameters, e.g., transmission rate, bandwidth, energy state of BSs. Moreover, the index of solar energy utilization balancing is proposed to improve the balance of energy utilization among different BSs in the proposed algorithm. Finally, simulation results demonstrate that the proposed algorithm performs excellently in improving solar energy utilization and reducing on-grid energy consumption of the HybE-Net.

Energy-efficiency enhancement and displacement-offset elimination for hybrid vibration control

  • Makihara, Kanjuro
    • Smart Structures and Systems
    • /
    • v.10 no.3
    • /
    • pp.193-207
    • /
    • 2012
  • New insights into our previously proposed hybrid-type method for vibration control are highlighted in terms of energy analysis, such as the assessment of energy efficiency and system stability. The hybrid method improves the bang-bang active method by combining it with an energy-recycling approach. Its simple configuration and low energy-consumption property are quite suitable especially for isolated structures whose energy sources are strictly limited. The harmful influence of the external voltage is assessed, as well as its beneficial performance. We show a new chattering prevention approach that both harvests electrical energy from piezoelectric actuators and eliminates the displacement-offset of the equilibrium point of structures. The amount of energy consumption of the hybrid system is assessed qualitatively and is compared with other control systems. Experiments and numerical simulations conducted on a 10-bay truss can provide a thorough energy-efficiency evaluation of the hybrid suppression system having our energy-harvesting system.

Resource Assessment of Theoretical Potential of Ocean Energy in Korea (국내 해양에너지 이론적 잠재량 산정 연구)

  • HWANG, SUJIN;JO, CHULHEE
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.5
    • /
    • pp.465-472
    • /
    • 2019
  • This paper describes the resource assessment of theoretical potential of ocean energy including tidal current energy, tidal range energy, wave energy and ocean thermal energy in Korea to provide reliable basis for feasible development plan of ocean energy. Because of different characteristics of each ocean energy resources, the resource assessment methods were established considering characteristics of each ocean energy resources. The coastal region of Korea has been divided into 10 regions. The results show that tidal current energy is abundant in Incheon-Gyunggi and Jeollanam-do and tidal range energy is abundant in Incheon-Gyunggi. And wave energy is abundant in Jeollanam-do, Jeju and Gyeongsangbuk-do and there is ocean thermal energy in Gangwon-do and Gyeongsangbuk-do.

Can cities become self-reliant in energy? A technological scenario analysis for Kampala, Uganda

  • Munu, Nicholas;Banadda, Noble
    • Environmental Engineering Research
    • /
    • v.21 no.3
    • /
    • pp.219-225
    • /
    • 2016
  • Energy self-reliance is important for economic growth and development for any nation. An energy self-reliance technological analysis for Kampala the capital city of Uganda is presented. Three renewable energy sources: Municipal Solid Waste (MSW), solar and wind are assessed for the period of 2014 to 2030. Annual MSW generation will increase from $6.2{\times}10^5$ tons in 2014 to $8.5{\times}10^5$ and $1.14{\times}10^6$ tons by 2030 at 2% and 3.9% population growth respectively. MSW energy recovery yield varies from 136.7 GWh (2014, 65% collection) to 387.9 GWh (2030, 100% collection). MSW can at best contribute 2.1% and 1.6% to total Kampala energy demands for 2014 and 2030 respectively. Wind contribution is 5.6% and 2.3% in those respective years. To meet Kampala energy demands through solar, 26.6% of Kampala area and 2.4 times her size is required for panel installation in 2014 and 2030 respectively. This study concludes that improving renewable energy production may not necessarily translate into energy self-reliant Kampala City based on current and predicted conditions on a business as usual energy utilization situation. More studies should be done to integrate improvement in renewable energy production with improvement in efficiency in energy utilization.

A Supercapacitor Remaining Energy Control Method for Smoothing a Fluctuating Renewable Energy Power

  • Lee, Wujong;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.146-154
    • /
    • 2015
  • This paper proposes a control method for maintaining the energy level for a supercapacitor energy storage system coupled with a wind generator to stabilize wind power output. Although wind power is green and clean energy source, disadvantage of the renewable energy output power is fluctuation. In order to mitigate the fluctuating output power, supercapacitor energy storage system (SCESS) and wind power simulator is developed. A remaining energy supercapacitor (RESC) control is introduced and analyzed to smooth for short-term fluctuating power and maintain the supercapacitor voltage within the designed operating range in the steady as well as transient state. When the average and fluctuating component of power increases instantaneously, the RESC compensates fluctuating power and the variation of fluctuating power is reduced 100% to 30% at 5kW power. Furthermore, supercapacitor voltage is maintained within the operating voltage range and near 50% of total energy. Feasibility of SCESS with RESC control is verified through simulation and experiment.

An Optimal Operation Model of A Centralized Micro-Energy Network (마이크로 에너지 네트워크의 중앙집중형 최적 운영 모델)

  • Lee, Ji-Hye;Kim, Hak-Man;Im, Young Hoon;Lee, Jae Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1451-1457
    • /
    • 2013
  • Recently, new concept of energy systems such as microgrid, smart grid, supergrid, and energy network has been introducing. In this paper, the concept of the centralized micro-energy network, which is an energy community of a building group without district heating system, is introduced. In addition, a mathematical model for optimal operation of the micro-energy network as a main function of an energy management system (EMS) for the micro-energy network is proposed. In order to show the validation, the proposed model is tested through the simulation and analyzed.

Seasonal Variation of Kinetic and Potential Energy of Residual Flow Field in Suyoung Bay, Korea (한국수영만에서 잔차류장의 운동 .위치에너지의 계절변화)

  • 김동선;유철웅
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.313-322
    • /
    • 1997
  • In order to study the seasonal variation of kinetic and potential energy of residual flow field In Suyoung Bay of Korea, we calculated Its energy budget and compared It with the tidal energy there. The potential energy shows the large value In winter and spring and the small one In summer and early autumn when the density stratification Is developed. The kinetic energy of residual flow varies seasonally and the seasonally averaged kinetic energy of residual flow per unit area is 6.4$\times$$10^{-4}ergs s^{-1}cm^{-}2$. It Is mainly governed by the density-driven current with the exception of that In November when the kinetic energy of tide-induced residual current is larger than those of density-driven current and wind-driven current. An averaged traction of the kinetic energy of tide-Induced residual current, wind-driven current and density-driven current, which are the major components of residual flow, is 29.1%, 3.4%, 67.5%, respectively, to the kinetic energy of residual flow, The fraction of kinetic energy of residual flow, potential energy and tidal energy per unit area is 1.0 : 6.7$\times$$10^3$: 8.2$\times$$10^4$ respectively.

  • PDF

Development of Sensor Based Energy Management System (센서기반 에너지 모니터링 프로토타입 시스템)

  • Um, Dae-Jin;Choi, Jung-In;Lee, Ingyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.69-74
    • /
    • 2014
  • With the increasing interest of energy efficiency, several buildings and factories begin to monitor energy usages with a built-in energy management system. However, the built-in energy monitoring system does not reflect the dynamics of buildings and factories energy usage. To overcome the latter, we deploy several sensors to monitor the dynamics of buildings energy usage patterns. In this paper, we are proposing a framework of a sensor based energy monitoring system. Based on our limited experiments, we can monitor power usages by a person, device and time period. As a result, we can plan a better energy usage and improve energy efficiency by the monitored energy usage profile data.

Characteristics Analysis of Domestic Wind Energy Resources (국내의 풍력자원 특성 분석)

  • Park, Kyung-Ho;Kim, Keon-Hoon;Chung, Hun-Saeng
    • Solar Energy
    • /
    • v.10 no.2
    • /
    • pp.3-9
    • /
    • 1990
  • The recent technology of Wind Energy Conversion System(WECS) in the world is well-developed and the feasibility of WECS is better than the past time. So, it is necessary to re-analyze the characteristics of wind energy in this country. This paper deals with the analysis of wind energy distribution in Korean Peninsula, Cheju and Ullung island. The assessment was performed based on the raw data collected 64 meteorological stations for the last 10 years. The wind energy characteristics were analyzed hourly, monthly, seasonally and annually. The Weibull distribution was assumed and two parameters in all areas were calculated and the wind energy potential distribution in Korea was obtained.

  • PDF

Measurements of proton beam flux and energy of APEP using foil activation technique

  • Wenlin Li;Qifan Dong;Hantao Jing;Li Ou;Zhixin Tan;Sixuan Zhuang;Qingbiao Wu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.328-334
    • /
    • 2024
  • The activation method of metallic foils is an important technique to measure the flux and energy of proton beams. In this paper, the method was used to measure the CSNS APEP proton flux at seven nominal proton energies ranging from 10 MeV to 70 MeV for beam spot sizes of the 20 mm × 20 mm and 50 mm × 50 mm. The reactions of natTi(p, x)48V, natNi(p, x)57Ni, natCu(p, x)58Co, and 27Al(p, x)24Na were employed to measure the proton beam flux with a range of 107-109 p/cm2/s. Furthermore, we also proposed a method using the activity ratio with a stacked-foil target to determine the energy spread of a Gaussian-like distribution for different nominal proton energies. The optimal combinations of Al, Cu, Ti, Ni, Mo, Fe, Nb, and In foils were adopted for the proton energies. The measured energy spreads for degraded beams of 30 MeV-70 MeV were found to be smaller than 10.00%.