• Title/Summary/Keyword: ENERGY model

Search Result 11,789, Processing Time 0.042 seconds

Analysis of Potential Reductions of Greenhouse Gas Emissions on the College Campus through the Energy Saving Action Programs

  • Woo, Jeongho;Choi, Kyoung-Sik
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.191-197
    • /
    • 2013
  • Republic of Korea announced the reduction target to be around 30% of business as usual greenhouse gas emissions by 2020. College campuses were ranked at the 5th of high energy consumption areas in the building sectors. Target management scheme was designed to set greenhouse gas emissions target including several college campuses. Previous studies showed the amount of greenhouse gas emissions with several assumptions such as the applications of renewable energy systems and light emitting diode lamps, etc. Long-range Energy Alternatives Planning model was utilized to simulate future greenhouse gas emissions. This study sets standard model labs for energy saving action programs by applying guidance studies. It has been deduced that energy saving action programs was responsible for reducing 949.5 kWh for each standard model lab and the total reduction of all 59 model labs in the Engineering College building has been calculated to 56,020.5 kWh. The objective of the study is to provide guidelines on standard model laboratory for greenhouse gas emissions reduction on the campus.

Electrostatic Discharge Energy Estimation of the Charged Human Body by the Rompe-Weisel Model (Rompe-Weisel Model에 의한 대전 인체의 정전기 방전 에너지 평가)

  • 이종호;김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.54-59
    • /
    • 2003
  • The discharge energy by electrostatic discharge of the charged human body is calculated under the assumption that the stored charge is dissipated completely. However, it is well-known that the charge is slightly remained after electrostatic discharge. Therefore, The Rompe-Weisel model of the discharge analysis, which has somewhat more of a physical justification than the conventional energy equation, is proposed. It is proposed that the electrical conductivity of the arc should be proportional to the energy density transferred to it by Ohmic dissipation. For the electrostatic discharge energy analysis, the Rompe-Weisel model was compared by quasi static analysis. As a consequence, a study on a reliable energy evaluation based on simulation models during electrostatic discharge is carried out in this paper and is adopted to estimate the explosion hazards of flammable gases.

A Study on the Perfomance Analysis of Low Energy Cooling Systems in Office building (사무소건물의 에너지절약형 냉방시스템 성능분석에 관한 연구)

  • Park, Chang-Bong;Rhee, Eon-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.89-94
    • /
    • 2010
  • A large portion of the energy cost of a building is cooling and heating to maintain a comfortable indoor environment. Air conditioning is now one of the important parts in the building design, as increase in energy consumption and pollutant emission in energy conversion process. In this study, elements that affects the energy consumption of model building are identified and the perfomance analysis of the alternative a Low Energy Cooling Systems considering characteristics of model building and energy saving performance is analyzed. In this study, elements that affect the energy consumption of office building are identified and energy saving performance of the alternative air conditioning system is analyzed. As a result, applied to earn and suggest basic data for energy saving measures. In this study, EnergyPlus simulation program was used to evaluate the energy load when alternative Low Energy Cooling Systems are applied to the model building. The reliability of simulation program is verified by comparing actual energy load from operation data of building management office and predicted energy load using simulation program. For Low Energy Cooling System application which considers the purpose and characteristics of the building, reasonable and energy-saving air conditioning method obtained by analyzing energy consumption elements for each expected air conditioning methods is used to deduct result of this study.

Model-independent reconstruction of the equation of state of dark energy

  • Hwang, Seung-gyu;L'Huillier, Benjamin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.69.1-69.1
    • /
    • 2020
  • While Dark Energy is one of the explanations for the accelerating expansion of the Universe, its nature remains a mystery. The standard (flat) ΛCDM model is consistent with cosmological observations: type Ia Supernova, BAO, CMB, and so on. However, the analysis of observations assuming a model, model-dependent approach, is likely to bias the results towards the assumed model. In this poster, I will introduce model-independent approach with Gaussian process and the application of Gaussian process regression to reconstruct the equation of state of dark energy.

  • PDF

Development of Bottom-up model for Residential Energy Consumption by Use (생활행위 분류에 의한 가정부문 용도별 에너지소비 분석모형 개발)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.22 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • There was a dire need to compile data about energy consumption data by use to analyze residential energy consumption patterns relating to changes in lifestyles, or changes in life behavior. Accordingly, bottom-up model for residential energy consumption by residential use was developed by life behavior classification in an attempt to analyze energy consumption. This paper multiplied each appliance's running times by each appliance by life behavior and built a residential bottoms-up model to figure out the energy consumption of each household. The uses by life behavior were broken down into lighting, heating, cooling, entertainment, obtaining information, hygiene, and cooking.

Analysis of the Factor of Renewable Energy Consumption in Korea, China and Japan (한.중.일의 신재생에너지 소비량 결정 요인 분석에 관한 연구)

  • Jeon, Mi-Hwa;Jang, Woon-Jeong;Kim, Yoon-Kyung
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.13-21
    • /
    • 2010
  • This paper analyzes the factors of renewable energy consumption in Korea, China and Japan. We consider renewable energy consumption per capita as dependent variable, GDP per capita, $CO_2$ emissions per capita and real oil prices as independent variables. To analyze this model, this paper uses three econometric methods such as OLS, fixed effect model and panel GLS, utilizing data from 1990 to 2006 in Korea, China and Japan. According to the results by OLS for each country, an increase in GDP per capita or $CO_2$ emissions per capita or oil prices leads to an increase in renewable energy consumption. According to the results by fixed effect model, an increase in GDP per capita or $CO_2$ emissions per capita leads to an increase in renewable energy consumption. And real oil prices do not have a significant impacts on this model. According to the results by panel GLS, an increase in real GDP per capita as a proxy of income leads to an increase renewable energy consumption. And both $CO_2$ emissions per capita and real oil prices do not correlated closely with renewable energy consumption. Thus oil is not substituted to renewable energy in Northeast asian countries.

Creep strain modeling for alloy 690 SG tube material based on modified theta projection method

  • Moon, Seongin;Kim, Jong-Min;Kwon, Joon-Yeop;Lee, Bong-Sang;Choi, Kwon-Jae;Kim, Min-Chul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1570-1578
    • /
    • 2022
  • During a severe accident, steam generator (SG) tubes undergo rapid changes in the pressure and temperature. Therefore, an appropriate creep model to predict a short term creep damage is essential. In this paper, a novel creep model for Alloy 690 SG tube material was proposed. It is based on the theta (θ) projection method that can represent all three stages of the creep process. The original θ projection method poses a limitation owing to its inability to represent experimental creep curves for SG tube materials for a large strain rate in the tertiary creep region. Therefore, a new modified θ projection method is proposed; subsequently, a master curve for Alloy 690 SG material is also proposed to optimize the creep model parameters, θi (i = 1-5). To adapt the implicit creep scheme to the finite element code, a partial derivative of incremental creep with respect to the stress is necessary. Accordingly, creep model parameters with a strictly linear relationship with the stress and temperature were proposed. The effectiveness of the model was validated using a commercial finite element analysis software. The creep model can be applied to evaluate the creep rupture behavior of SG tubes in nuclear power plants.

Experimental investigation on multi-parameter classification predicting degradation model for rock failure using Bayesian method

  • Wang, Chunlai;Li, Changfeng;Chen, Zeng;Liao, Zefeng;Zhao, Guangming;Shi, Feng;Yu, Weijian
    • Geomechanics and Engineering
    • /
    • v.20 no.2
    • /
    • pp.113-120
    • /
    • 2020
  • Rock damage is the main cause of accidents in underground engineering. It is difficult to predict rock damage accurately by using only one parameter. In this study, a rock failure prediction model was established by using stress, energy, and damage. The prediction level was divided into three levels according to the ratio of the damage threshold stress to the peak stress. A classification predicting model was established, including the stress, energy, damage and AE impact rate using Bayesian method. Results show that the model is good practicability and effectiveness in predicting the degree of rock failure. On the basis of this, a multi-parameter classification predicting deterioration model of rock failure was established. The results provide a new idea for classifying and predicting rockburst.

A Study on the Estimation model of the Amount of the Electric Energy Consumption according to the Apartment Heating Type (공동주택 난방방식별 전력에너지 소비량 추정모델 작성 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Ryu, U-Sang
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Electric energy is indispensible of the development of the industrial and living sector. Among the energy sectors, the building area shares 20% of the produced electric power in Korea. As we plan to supply the apartment, we need to forecast the required amount of the electric energy and supply the infrastructure to apartment for the lighting, cooling. Nonetheless, it is not easy to forecast the required amount of the electric energy, considering the management aspect, building physical aspect and social-geographic aspect. In this paper, it studied the estimation model of the electric energy, reflecting the affecting variables such as total area, number of household, geography and so on. The estimation model is proposed in 3-types which explained in central heating, individual heating and district heating, and each type have two estimation model, reflecting the affecting variable and corelation between variables to eliminate the muticolinearity. The unit of electric energy consumption per area and year is similar in three heating type and the results are as follows; the central heating is $34.446kWh/yr{\cdot}m^2$, individual type is $35.756446kWh/yr{\cdot}m^2$ and district heating is $34.285446kWh/yr{\cdot}m^2$.

A new practical equivalent linear model for estimating seismic hysteretic energy demand of bilinear systems

  • Samimifar, Maryam;Massumi, Ali;Moghadam, Abdolreza S.
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.289-301
    • /
    • 2019
  • Hysteretic energy is defined as energy dissipated through inelastic deformations during a ground motion by the system. It includes frequency content and duration of ground motion as two remarkable parameters, while these characteristics are not seen in displacement spectrum. Since maximum displacement individually cannot be the appropriate criterion for damage assessment, hysteretic energy has been evaluated in this research as a more comprehensive seismic demand parameter. An innovative methodology has been proposed to establish a new equivalent linear model to estimate hysteretic energy spectrum for bilinear SDOF models under two different sets of earthquake excitations. Error minimization has been defined in the space of equivalent linearization concept, which resulted in equivalent damping and equivalent period as representative parameters of the linear model. Nonlinear regression analysis was carried out for predicting these equivalent parameter as a function of ductility. The results also indicate differences between seismic demand characteristics of far-field and near-field ground motions, which are not identified by most of previous equations presented for predicting seismic energy. The main advantage of the proposed model is its independency on parameters related to earthquake and response characteristics, which has led to more efficiency as well as simplicity. The capability of providing a practical energy based seismic performance evaluation is another outstanding feature of the proposed model.