• 제목/요약/키워드: EMTDC/PSCAD

검색결과 690건 처리시간 0.026초

PSCAD응용:태양광및연료전지발전시스험의계통연재를 위한 단상인버터모델 (APSCAD/Application:Single-phaseUtility-ConnectableInverterModelforPVorFCSystem)

  • 캠벨라이언;이종수;신명철;김학만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.276-279
    • /
    • 2004
  • The purpose of this paper is to describe and demonstrate how a utility-connectable inverter for photovoltaic or fuel-cell applications can be well modeled using PSCAD/EMTDC. In this paper, a single-phase IGBT inverter using SPWM is modeled. Simple voltage magnitude and phase controls are implemented using PSCAD's Pl controller, PLL, and a 'user defined' component called Modulo (found in their extensive collection of example circuits). The circuit model also takes advantage of PSCAD's interpolated firing pulse option, which provides improved simulation results by preventing errors from being introduced when switches fire between time simulation steps. Additionally, SCAD's Online Frequency Scanner for FFT is utilized for a demonstration of PSCAD's frequency-domain analysis capabilities.

  • PDF

EMTDC를 이용한 80MVA UPFC(Unified Power Flow Controller) 계통적용 효과 분석 (The Analysis of 80MVA UPFC application effect using EMTDC)

  • 윤종수;장병훈;오관일;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.93-96
    • /
    • 2001
  • 본 논문은 2003년 한전 실계통(154kV 강진 S/S)에 적용예정인 80MVA UPFC(Unified Power Flow Controller) 시스템의 적용효과를 EMTDC/PSCAD 프로그램을 이용하여 분석한 결과이다. UPFC는 현재까지 개발된 FACTS 기기중 전압, 임피던스, 위상각등 전력전송 제어를 위한 송전선로의 모든 파라미터를 동시에 제어 할 수 있는 유일한 FACTS기기[1]로서 미국 Inez S/S에 이어 세계 두번째로 강진 S/S에 80MVA 용량의 UPFC가 실계통 적용될 예정이다. 본 논문은 대표적인 과도현상 해석프로그램인 EMTDC를 이용한 80MVA UPFC의 적용시 계통 제어효과 분석에 대하여 기술하였다. 적용된 EMTDC UPFC모델은 실제 80MVA UPFC 기기 전력회로, 제어기와 동일하게 모델링하였으며 적용 대상계통은 한전 계통 데이터를 바탕으로 강진 S/S인근 계통을 축약 등가화한 계통모델을 사용하였다.

  • PDF

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF

영구자석동기발전기 풍력시스템의 하드웨어 시뮬레이터 개발 (Development of Hardware Simulator for PMSG Wind Power System)

  • 이두영;윤동진;정종규;양승철;한병문;송승호
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.951-958
    • /
    • 2008
  • This paper describes development of hardware simulator for the PMSG wind power system, which was designed considering wind characteristic, blade characteristic and blade inertia compensation. The simulator consists of three major parts, such as wind turbine model using induction motor, PMSG generator, converter-inverter set. and control system. The turbine simulator generates torque and speed signals for a specific wind turbine with respect to given wind speed. This torque and speed signals are scaled down to fit the input of 2kW PMSG. The PMSG-side converter operates to track the maximum power point, and the grid-side inverter controls the active and reactive power supplied to the grid. The operational feasibility was verified by computer simulations with PSCAD/EMTDC, and the implementation feasibility was confirmed through experimental works with a hardware set-up.

순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption)

  • 김희중;배병열;한병문;설승기;조보형
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

저단락비 HVDC 시스템에서웨 무효편력수급 최적 방안 연구 (Study on Optimized Scheme of Reactive Power Compensation for Low Short-Circuit-Ratio HVDC System)

  • 백승택;한병문;오세승;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.434-440
    • /
    • 2005
  • This paper describes an optimized Scheme of reactive-power compensation for the low short-circuit-ratio AC system interconnected with the HVDC system. An HVDC system interconnected with tile low SCR AC system is vulnerable to the ac voltage variation, which brings about the commutation failure of the converter. This problem can be solved using optimized compensation of reactive power. In this study, a benchmark system for HVDC system interconnected with low SCR AC system is derived using PSS/E simulation. Then an optimized srheme for reactive power compensation was derived using integer programming. The feasibility of proposed scheme was analyzed through silnulations with PSS/E and PSCAD/EMTDC. The proposed scheme can compensate the reactive power accurately and minimize the number of switching for harmonic filters and shunt reactors.

계통 연계형 권선형 유도발전기의 동작특성 연구 (Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network)

  • 김찬기;한상열;추진부
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.247-257
    • /
    • 2006
  • 본 논문은 이중여자권선을 갖는 권선형 유도발전기와 농형유도발전기사이의 운전특성비교를 보여준다. 농형유도발 전기는 자화리액턴스에 의한 무효전력소비 때문에, 역률을 보상하기 위한 콘덴서를 필요로 하나, DFIG는 회전자에 Back-To Back컨버터를 가지고 있기 때문에 저속/고속에서 유도발전기가 운전이 가능하다. 본 논문에서는 PSCAD/TMTDC를 이용하여 농형유도기와 DFIG의 응답특성이 분석되었다.

배전시스템에서의 저항형 초전도 한류기 파라미터 산정방법 (Application Analysis of a Resistive type SFCL for Distribution Systems)

  • 허태전;배형택;박민원;유인근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.28-31
    • /
    • 2004
  • Since the discovery of the high temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results. significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a distribution system are performed by the PSCAD/EMTDC-based simulation method in which a component for resistive type ot SFCL is presented. Through the simulation. the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended.

Modular Multilevel Converter 시스템을 위한 PSCAD/EMTDC 시뮬레이션 (PSCAD/EMTDC Simulation for Modular Multilevel Converter System)

  • 손금태;이희진;백승택;이욱화;정용호;허견;박정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1214-1215
    • /
    • 2011
  • 현재 HVDC 및 FACTS와 같은 전력전자소자 기반 전력기기의 최신 개발은 능동형 스위치소자의 발전 및 설치 환경의 변화로 인하여 VSC Topology로 이동되고 있다. 하지만 VSC Toplolgy의 스위칭 손실등의 문제로 대용량 전력기기의 경우 MMC(Modular Multilevel Converter) 적용이 가속화되고 있다. 이에 본 논문에서는 MMC Topology의 특징, 구동 원리, 시뮬레이션 과정을 소개한다. Modulation 및 Quantization 그리고 Sorting Algorithm을 통해 7-level, 151-level 삼상 MMC Topology을 시뮬레이션을 수행하였다.

  • PDF

고속전철 변전소의 고조파 분석과 대책에 관한 연구 (A Study on Harmonic Analysis and Countermeasure at the High Speed Railway Substation)

  • 김재철;박수만;강창원
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.138-143
    • /
    • 2004
  • 본 논문은 고속전철 차량에서부터 변전소까지의 고조파에 대해서 분석하였으며, 수동필터를 이용한 고조파 저감 방법을 제시한다. 고속전철 변전소가 공급하는 열차구간에 있어서 운행 열차의 수에 따라 고조파의 파급 특성을 살펴보았다. 고조파는 변압기 과열과 통신유도장해 등 문제를 일으킬 수 있다. 이러한 고조파에 의한 손상을 줄이기 위하여 본 논문은 고조파 저감방법을 제시하였다. 제안된 방법은 PSCAD/EMTDC 시뮬레이션에 의해 증명되었다.