• Title/Summary/Keyword: EMR시스템

Search Result 115, Processing Time 0.018 seconds

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

Database for Hospice Nursing in Electronic Medical Record (호스피스 전자기록을 위한 데이터베이스 개발)

  • Kim, Young-Soon;Lee, Chang-Geol;Lee, Kyoung-Ok;Kim, Ok-Kyum;Kim, In-Hye;Kim, Mi-Jeong;Hwang, Ae-Ran;Lee, Won-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.7 no.2
    • /
    • pp.200-213
    • /
    • 2004
  • Purpose: The purpose of this study was to create an electronic nursing record form to build a hospice nursing process database to be used in the u-hospital EMR system. Specific aims of the study were: 1. To generate a complete, accurate, and simple electronic nursing record form. 2. To verify its appropriateness following documentation with the standardized hospice protocol. 3. To verify its validity and finalize the hospice nursing process database through discussion among hospice professionals. Methods: Nursing records from three independent hospice organizations were collected and analyzed by five expert hospice nurses with more than 10 years of experience, and a nursing record database was developed. This database was applied to 81 hospice patients at three hospice organizations to verify its completeness. Results: 1. An electronic nursing record form with completeness, accuracy, and simplicity was developed. 2. The completeness of the standardized home hospice service protocol was 95.86 percent. 3. The hospice nursing process database contains 18 items on health problems, 79 items on related causes and major symptoms, and 229 items on nursing interventions. Conclusion: The new nursing record form and database will reduce documentation time and articulate and streamline the working process among team members. They can also improve the quality of hospice services, and ultimately enable us to estimate hospice service costs.

  • PDF

Analyzing Health Information Technology and Electronic Medical Record System-Related Patient Safety Incidents Using Data from the Korea Patient Safety Reporting and Learning System (환자안전보고학습시스템 자료를 활용한 의료정보기술 및 전자의무기록시스템 관련 환자안전사건 분석)

  • Cho, Dan Bi;Lee, Yu-Ra;Lee, Won;Lee, Eu Sun;Lee, Jae-Ho
    • Quality Improvement in Health Care
    • /
    • v.27 no.2
    • /
    • pp.57-72
    • /
    • 2021
  • Purpose: At present, there are a variety of serious patient safety incidents related to problems in health information technology (HIT), specifically involving electronic medical records (EMRs). This emphasizes the need for an enhanced electronic medical record system (EMRS). As such, this study analyzed both the nature of and potential to prevent incidents associated with HIT/EMRS based on data from the Korea Patient Safety Reporting and Learning System (KOPS). Methods: This study analyzed patient safety incidents submitted to KOPS between August 2016 and December 2019. HIT keywords were used to extract HIT/EMRS incidents. Each case was reviewed to confirm whether the contributing factors were related to HIT/EMRS (HIT/EMRS-related incidents) and if the incident could have been prevented (HIT/EMRS-preventable incidents). The selected reports were summarized for general clarity (e.g., incident type, and degree of harm). Results: Of the 25,515 obtained reports, 2,664 incidents (10.4%) were HIT-related, while 2,525 (9.9%) were EMRS-related. HIT/EMRS-related incidents were the third largest type of incident followed by 'fall' and 'medication incidents.' More than 80% of HIT/EMRS-related incidents were medication-related, accounting for approximately one-third of the total number of medication incidents. Approximately 10% of HIT/EMRS-related incidents resulted in patient harm, with more than 94% of these deemed as preventable; further, sentinel events were wholly preventable. Conclusion: This study provides basic data for improving EMR use/safety standards based on real-world patient safety incidents. Such improvements entail the establishment of long-term plans, research, and incident analysis, thus ensuring a safe healthcare environment for patients and healthcare providers.

Consideration of Adverse Reaction to MDCT Contrast Media (MDCT에 사용되는 조영제의 부작용에 대한 고찰)

  • Yang, Won-Seok;Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.51-57
    • /
    • 2012
  • In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows : use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF