• Title/Summary/Keyword: EMP filter

Search Result 7, Processing Time 0.019 seconds

Novel Partitioning Algorithm for a Gaussian Inverse Wishart PHD Filter for Extended Target Tracking

  • Li, Peng;Ge, Hongwei;Yang, Jinlong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5491-5505
    • /
    • 2017
  • Use of the Gaussian inverse Wishart PHD (GIW-PHD) filter has demonstrated promise as an approach to track an unknown number of extended targets. However, the partitioning approaches used in the GIW-PHD filter, such as distance partition with sub-partition (DP-SP), prediction partition (PP) and expectation maximization partition (EMP), fails to provided accurate partition results when targets are spaced closely together and performing maneuvers. In order to improve the performance of a GIW-PHD filter, this paper presents a cooperation partitioning (CP) algorithm to solve the partitioning issue when targets are spaced closely together. In the GIW-PHD filter, the DP-SP is insensitive to target maneuvers but sensitive to the differences in target sizes, while EMP is the opposite. The proposed CP algorithm is a fusion approach of DP-SP and EMP, which employs EMP as a sub-partition approach after DP. Therefore, the CP algorithm will be sensitive to neither target maneuvers nor differences in target sizes. The simulation results show that the use of the proposed CP algorithm will improve the performance of the GIW-PHD filter when targets are spaced closely together.

Estimation of the Penetrated Pulse using Measured Shielding Effectiveness (측정된 전자파 차폐율을 이용한 시스템 내부 침투파형 예측)

  • Kang, Rae-Choong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1121-1128
    • /
    • 2011
  • The HEMP has very short rising time with several tens of kV/m, and very dangerous to almost of the electronics. And the certain level of EMP shielding effectiveness is necessary for mos t of the systems andequipment. In EMP shielding effectiveness, the peak value and the rising time in the system are the most considerable parameters. In order to find out these parameters, we need to estimate the pulse shape in time domain. In this paper, we propose the methods to estimate the penetrated pulse in time domain using measured shielding effectiveness and digital filter modeling technique. The validity of the Digital filter modeling technique is verified by the HFSS.

Implementation of Dedicated Power Line Filter for HEMP Protection (HEMP 보호용 전원선 필터 구현)

  • Kim, Keun-Nam;Lee, Sung-Hwa;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.47-52
    • /
    • 2016
  • This paper covers the importance of a dedicated Power Line Filter implementation against HEMP(High altitude ElectroMagnetic Pulse) threats caused by high altitude nuclear detonations. As the PCI test results for E1 short pulse with 2500[A], only HEMP filter obtained the required residual current around 8[A], but others didn't meet below 10[A] on MIL-STD-188-125 PCI regulation. Consequently, the development of a dedicated power line filter turned out to be a essential element in order to protect the power related system against HEMP transient.

A Method to Suppress the Spurious Radiation due to the Current Pulse on the Cable using the Frequency Selective Metamaterial Structure (주파수 선택도를 가지는 메타재질구조를 이용한, 선로상의 전류펄스에 의한 불요방사 억제기법)

  • Kahng, Sungtek;Yang, Inkyu;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.517-522
    • /
    • 2013
  • The spurious electromagnetic radiation is generated due to the RF unbalanced current on a conductive cable connecting an electronic device to another. A metamaterial-based filtering geometry with frequency selectivity is suggested to reduce the radiation with a bandgap structure, where the right-handed inductance and capacitance stem from the transmission-like configuration between the cable and the metal protrusion, and the left-handed components come from the narrow cavities. The effect of the structure on the unbalanced current pulse and its spurious radiation is presented in the FDTD-method frame work.

Transparent Electrode Performance of TiO2/ZnS/Ag/ZnS/TiO2 Multi-Layer for PDP Filter (TiO2/ZnS/Ag/ZnS/TiO2 다층막의 PDP 필터용 전극 특성)

  • Oh, Won-Seok;Lee, Seo-Hee;Jang, Gun-Eik;Park, Seong-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.681-684
    • /
    • 2010
  • The $TiO_2$/ZnS/Ag/ZnS/$TiO_2$ multilayered structure for the transparent electrodes in plasma display panel was designed by essential macleod program (EMP) and the multilayered film was deposited on a glass substrate by direct-current (DC)/radio-frequency (RF) magnetron sputtering system. During film deposition process, the Ag layer in $TiO_2$/Ag/$TiO_2$ structure became oxidized and the filter characteristic was degraded easily. In this study, ZnS layer was adopted as a diffusion blocking layer between $TiO_2$ and Ag to prevent the oxidation of Ag layer efficiently in $TiO_2$/ZnS/Ag/ZnS/$TiO_2$ structure. Based on the AES depth profiling analysis, the Ag layer was effectively protected by the ZnS layer as compared with the $TiO_2$/Ag/$TiO_2$ multilayered films without ZnS as an antioxidant layer. The 3 times stacked $TiO_2$/ZnS/Ag/ZnS/$TiO_2$ films have low sheet resistance of $1.22{\Omega}/{\square}$ and luminous transmittance was as high as 62% in the visible ranges.

Effect of Si3N4 Buffer Layer on Transmittance of TiO2/Si3N4/Ag/Si3N4/TiO2 Multi Layered Structure (TiO2/Si3N4/Ag/Si3N4/TiO2 다층구조에서 Si3N4 버퍼층이 투과율에 미치는 영향)

  • Lee, Seo-Hee;Jang, Gun-Eik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The $TiO_2/Si_3N_4/Ag/Si_3N_4/TiO_2$ multi layered structure was designed for the possible application of transparent electrodes in PDP (Plasma Display Panel). Multi layered film was deposited on a glass substrate at room temperature by DC/RF magnetron sputtering system and EMP (Essential Macleod Program) was adopted to optimize the optical characteristics of film. During the deposition process, the Ag layer in $TiO_2/Ag/TiO_2$ became heavily oxidized and the filter characteristic was degraded easily. In thus study, Si3N4 layer was used as a diffusion buffer layer between $TiO_2$ and Ag. in order to prevent the oxidation of Ag layer in $TiO_2/Si_3N_4/Ag/Si_3N_4/TiO_2$ structure. It was confirmed that $Si_3N_4$ layer is one of candidate materials acting as diffusin barrier between $TiO_2/Ag/TiO_2$.

Development of the HEMP Generation, Propagation Analysis, and Optimal Shelter Design Tool (고 고도 전자기파(HEMP) 발생과 전파해석 및 방호실 최적 설계 Tool 개발)

  • Kim, Dong Il;Min, Gyeong Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2331-2338
    • /
    • 2014
  • The HEMP threat may have acquired new, and urgent, relevance as the proliferation of nuclear weapons and missile technology accelerates of the North Korea, for example, is assessed as already having developed few atomic weapons, and is on the verge of North Korea already has missiles capable of delivering a nuclear warhead against South Korea. ITU K.78, K81 and IEC recommended its counter-measuring for the industrial facilities with navigation and sailing facilities in order to obviate the all of processor equipped system malfunctions from the EMP/HEMP but its simulation must only be done by the computer simulation which had studied on the 1960-1990 years USA/AFWL papers. This result has a significant activities to the South Korea being under the North Korea threat because all of HEMP related products was strongly limited for export. The HEMP cord which was developed newly by the KTI including the HEMP generation & propagation analysis, optimal shelter design tool, essential EM energy attenuation in multi-layered various soils and rocks and HEMP filter design tool. Especially, the least square fitting method was adopted to analysis for the EM energy attenuation in the soils and rocks because it has a various characteristics based on the many times field test reports.