• Title/Summary/Keyword: EMG(Electromyography)

Search Result 609, Processing Time 0.025 seconds

A Study of Surface Electromyography Measurement of Facial Muscles in Normal Person (정상인의 안면부 운동 시 표면근전도 측정 연구)

  • Lee, Hyung Geol;Jung, Da Jung;Choi, Yoo Min;Kim, Suk Hee;Yook, Tae Han;Song, Beom Yong;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2014
  • Background or Objectives : The purpose of this study is to measure surface Electromyography(sEMG) of facial muscles in normal person and to find method for standardizing of sEMG's value. Methods : We measured 3points on face, frontalis muscle($GB_{14}$), zygomaticus muscle($SI_{18}$), orbicularis oris muscle($LI_{19}$) of 40 normal person by sEMG. 40 normal person consist with two groups, each 20 male, 20 female. Average age of subject was $26.50{\pm}4.79$. SEMG instrument QEMG-4 XL was used. After training exercise of facial muscles, sEMG's root mean square value was measured once. Results : 1. In whole experimental group, frontalis muscle's both side average was $78.36{\pm}40.87$, zygomaticus muscle's both side average was $84.70{\pm}49.81$, orbicularis oris's both side average was $104.83{\pm}38.81$. 2. Left side of Frontalis muscle, both side of zygomaticus muscle are high marked in male than female in statistically. 3. In whole experimental group, average of ratio comparing smaller value with bigger value in difference between left side and right side was $19.60{\pm}12.88$ %. 4. Average of asymmetry index(AI) was $11.46{\pm}8.36$ %. orbicularis oris muscle's average of AI had least difference was $8.95{\pm}7.50$ %. zygomaticus muscle's average of AI had most difference was $13.95{\pm}8.90$ %. Conclusions : The result of this study could provide useful information of field of sEMG is used in oriental medicine treatment of facial muscles. To assess efficacy of treatment in facial muscles, we need to standardize facial muscle's sEMG values by using AI, ratio comparing values and etc.

Correlation between Surface Electromyography and Conventional Electromyography in Facial Nerve Palsy (안면마비 환자에서 표면 근전도 검사와 통상적 근전도 검사간 상관관계)

  • Jang, Haneul;Yoo, Seung Don;Lee, Jong Ha;Soh, Yunsoo;Kim, Dong Hwan;Chon, Jinmann;Lee, Seung Ah;Kim, Hee-Sang;Yun, Dong Hwan;Kwon, Jung Ho
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.84-90
    • /
    • 2018
  • Objective: To assess the correlation between surface electromyography (SEMG) and conventional EMG in patients with facial nerve palsy. Additionally, compare the discomfort and the time required by the patients in two methods. Method: 36 patients with facial palsy were given nerve conduction studies (NCS) via conventional EMG. Then, the peak root mean square (RMS) values were obtained from the SEMG. We also recorded visual analogue scale (VAS), House-Brackmann scale, and the time required for the examination. Results: Pearson's correlation coefficient between the amplitude loss ratio of the RMS values obtained by SEMG compared to the unaffected side (RSEMG) and the amplitude loss ratio of CMAP amplitudes compared to the unaffected side (RCMAP) was 0.567 at the frontalis, 0.456 at the orbicularis oculi, 0.393 at the nasalis, and 0.437 at the orbicularis oris. An increase in RSEMG is positively correlated with an increase in RCMAP. The mean VAS score with conventional EMG was $3.55{\pm}1.42$, whereas that experienced when using SEMG was $0.11{\pm}0.52$ and the mean time required for conventional EMG was $610{\pm}103.84$ seconds, while that required for SEMG was $420{\pm}86.32$ seconds. Conclusion: This study demonstrated a significant positive correlation between facial muscle activities as measured by SEMG and conventional EMG in patients with facial nerve palsy. SEMG has the benefits of being more comfortable and faster when diagnosing facial palsy.

Clinical Application of Electromyography and Nerve Conduction Study (근전도와 신경전도 검사의 임상적 응용)

  • Kim Ho-Bong;Park Young-Han;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.199-212
    • /
    • 1998
  • The purpose of this article is to summary about the application of electromyography and nerve conduction study. Electrodiagnostic studies, which include nerve conduction studies, electromyography, repetitive nerve stimulation, single fiber EMG, late response tests and evoked potential tests are a critical component of the neuromuscular evaluation.

  • PDF

Clinical Application of Electromyography and Nerve Conduction Study (근전도와 신경전도 검사의 임상적 응용)

  • Kim, Ho-Bong;Bae, Sung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.2
    • /
    • pp.603-616
    • /
    • 1998
  • The purpose of this article is to summary about the application of electromyography and nerve conduction study. Electrodiagnostic studies, which include nerve conduction studies, electromyography, repetitive nerve stimulation, single fiber EMG, late response tests and evoked potential tests are a critical component of the neuromuscular evaluation.

  • PDF

Changes of Upper Trapezius Muscle Activity and EMG Gap After Transcutaneous Electrical Nerve Stimulation in Subjects With Myofascial Pain Syndrome (경피신경전기자극 후 상부 승모근 활성도와 EMG gap의 변화)

  • Koh, Eun-Kyung;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.37-50
    • /
    • 2003
  • The purpose of this study was to compare visual analogue scale (VAS), pain threshold (PT), $%RMS_{RVC}$, and EMG gaps before and after applying transcutaneous electrical nerve stimulation (TENS) on the upper trapezius muscle at the patients with myofascial pain syndrome (MPS). The subjects were 4 men and 10 women composed of both the inpatients and outpatients who were diagnosed as MPS at Wonju Medical Center. VAS and PT measurements were performed to assess the subjective pain level. The reference voluntary contraction (RVC) test was performed for 15 seconds for normalization on the bilateral trapezius muscle using surface electromyography (sEMG). After 3-minute resting time, the EMG signal was recorded while performing a typing activity for 2 minutes and then TENS was applicated with a comfortable intensity for 10 minutes. The EMG activity of the upper trapezius muscle was recorded during typing for 2 minutes. The results of study were as follows: 1) VAS score was significantly decreased on the more painful side after treatment, however, it was not significantly different on the less painful side. 2) PT was increased after treatment on both sides, however, it was not significantly different between before and after the TENS application. 3) The EMG activity during typing was significantly decreased after treatment, and 4) The EMG gaps were significantly increased after TENS treatment compared to before it. Consequently, the study showed that TENS was effective in decreasing VAS, $%RMS_{RVC}$, and in increasing EMG gaps. The EMG gap analysis could be a useful method to measure pain in patients with MPS in the upper trapezius.

  • PDF

Human-Machine Interaction based on a Real-time Upper Limb Motion Prediction using Surface Electromyography (표면 근전도 신호를 이용한 실시간 상지부 동작 예측을 통한 인간-기계 상호작용)

  • Kwon, Sun-Cheol;Kim, Jung
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.418-421
    • /
    • 2009
  • This paper presents a human-machine interaction based on a realtime upper limb motion prediction method using surface electromyography (sEMG). The motions were predicted using an artificial neural network algorithm and sEMG signals which are acquired from five muscles, and then a manipulator was controlled to follow after the predicted motions. Upper limb motions were restricted to 2D vertical plane with the contact condition between a user and an end-effector of manipulator. In order to demonstrate the feasibility of the proposed method, experiments using developed method and using a goniometer were performed. The results showed that the proposed real-time motion prediction method can be implemented a human-machine interaction system.

  • PDF

Pneumothorax Following Needle Electromyography in a Patient with Amyotrophic Lateral Sclerosis Who Presented with Respiartory Failure As an Initial Symptom (호흡곤란을 초기 증상으로 내원한 근육위축가쪽경화증 환자에서 침근전도검사 후 발생한 기흉)

  • Lee, Seung-An;Lee, Hyun-Suk;Kim, Dae-Seong
    • Annals of Clinical Neurophysiology
    • /
    • v.10 no.1
    • /
    • pp.62-65
    • /
    • 2008
  • We report a patient with amyotrophic lateral sclerosis (ALS) who developed a pneumothorax after needle electromyography (EMG), probably of the intercostal muscles. Needle EMG on intercostal muscles has a high risk of pneumothorax, not only because electromyographers are unfamiliar to its technique, but also due to its close anatomical location to the pleural cavity. In our patient, advanced intercostal muscle atrophy due to disease process would have increased the risk further.

  • PDF

Estimation of Shoulder Flexion Torque and Angle from Surface Electromyography for Physical Human-Machine Interaction (물리적 인간-기계 상호작용을 위한 표면 근전도 신호 기반의 어깨 굴곡 토크 및 각도 추정)

  • Park, Ki-Han;Lee, Dong-Ju;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.663-669
    • /
    • 2011
  • This paper examines methods to estimate torque and angle in shoulder flexion from surface electromyography(sEMG) signals for intuitive and delicate control of robotic assistance device. Five muscles on the upper arm, three for shoulder flexion and two for shoulder extension, were used to offer favorable sEMG recording conditions in the estimation. The methods tested were the mean absolute value (MAV) with linear regression and the artificial neural network (ANN) method. An optimal condition was sought by varying combination of muscles used and the parameters in each method. The estimation performance was evaluated using the correlation values and normalized root mean square error values. In addition, we discussed their possible use as an estimation of motion intent of a user or as a command input in a physical human-machine interaction system.

Effect of Quadriceps Activity for Degenerative Arthritis Applied EMG Biofeedback Training (근전도 바이오피드백 훈련이 퇴행성 슬관절염 환자의 대퇴사두근 활성에 미치는 효과)

  • Kim, Young-Eok;Kim, Dong-Youn
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.6 no.1
    • /
    • pp.31-42
    • /
    • 2008
  • This study performed in order to investigate the effect of isometric resistance exercise for vastus medialis oblique muscle with EMG(electromyography) biofeedback training which are applied to the patello-femoral joint of patients with osteoarthritis on the improve of function. The subjects had no neuromuscular disorders, and they were elder patients with osteoarthritis, 20 women. And the experiment was performed in control group, taping with EMG biofeedback training group respectively, and the measurement was carried out before and after the treatment and 4 weeks after the treatment. Motor unit action potential analysis with surface electromyography showed a significant change in RMS(root mean square) amplitude and MDF(median frequency) in vastus medialis oblique muscle(p<0.05). VMO/VL(vastus medialis oblique/vastus lateralis oblique) MDF ratio showed a significant change between groups(p<0.05). Taping with EMG biofeedback training applied to patello-femoral joint of osteoarthritis patients appeared to be effective for muscle function improvement. However, increase of muscular force in vastus medialis oblique muscle appears to have a positive effect on improve of function along with correction effect on patella malalignment. In conclusion, in case of osteoarthritis patients with loss of patello-femoral joint function, it appears to be effective to practice isometric resistance exercise of vastus medialis oblique muscle selective with taping.

  • PDF

Prediction of Head Movements Using Neck EMG for VR (근전도 신호를 이용한 헤드-트래킹 지연율 감소 방안 연구)

  • Jung, Jun-Young;Na, Jung-Seok;Lee, Chae-Woo;Lee, Gihyeon;Kim, Jinhyun
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.365-370
    • /
    • 2016
  • The study about VR (Virtual Reality) has been done from the 1960s, but technical limits and high cost made VR hard to commercialize. However, in recent, high resolution display, computing power and 3D sensing have developed and hardware has become affordable. Therefore, normal users can get high quality of immersion and interaction. However, HMD devices which offer VR environment have high latency, so it disrupts the VR environment. People are usually sensitive to relative latency over 20ms. In this paper, as adding the Electromyogram (EMG) sensors to typical IMU sensor only system, the latency reduction method is proposed. By changing software and hardware components, some cases the latency was reduced significantly. Hence, this study covers the possibility and the experimental verification about EMG sensors for reducing the latency.