• 제목/요약/키워드: EMF Measurement

검색결과 80건 처리시간 0.025초

전력설비에 의한 자계 측정및 컴퓨터 시뮬레이션 (Magnetic Field Measurement and Computer Simulation for Electrical Utility Facilities)

  • 전형태;사재원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.22-24
    • /
    • 1996
  • For two decades and more, a lot of research work on the biological effects of EMF(Electromagnetic Fields) on Human hearth have been reported. Power-frequency magnetic fields are a natural consequence of the flow of electricity. This paper deals with the modeling of electric utility facilities taking into account the line geometries. The magnetic fields profiles obtained from the computer simulation arc compared to those from measurements.

  • PDF

불화물을 이용한 산소센서의 제조및 특성 (Fabrication and Characteristics of Oxygen Gas Sensor using Fluoride Compaunds)

  • 이재현;홍영호;장동근;이병택;김태훈;이덕동
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 1993년도 추계 학술발표 강연 및 논문 개요집
    • /
    • pp.69-71
    • /
    • 1993
  • Fluoride compound potentiometric cell oxygen sensors were fabricated for the measurement of oxygen pressure in the low temperature range (300。K-500。K). The disk type sensors consist of a reference Air(0$_2$):Ag, a solid electrolyte SrF$_2$, and a sensing metel Ag electrode. And the buried reference electrode type sensor have a NiO/Ni reference electrode. The open circuit emf of the cell showed high sensivity to oxygen gas (60mv) at the measuring temperature 20$0^{\circ}C$. Also, The buried reference electrode type sensor showed 30mv from 1% to 10% oxygen pressure range.

  • PDF

pH 측정 시스템의 표준화에 관한 연구 (Studies on the Standardization of pH Measurement System)

  • 이화심;김명수;김진복;오상협
    • 대한화학회지
    • /
    • 제42권4호
    • /
    • pp.432-442
    • /
    • 1998
  • $pH=-loga_H$ 정의에서 pH는 단일 이온의 활동도항을 포함하므로 단지 측정의 방법만으로는 결정되어질 수 없고 근사법을 필요로 한다. 근사법에 의한 pH 측정은 수소전극과 은/염화은 전극을 사용한 액간 접촉이 없는 cell의 기전력 측정으로부터 이루어지는 방법이며, 이 과정을 통해 pH 값이 인증된 pH의 일차 표준 물질을 얻을 수 있다. 일반적인 pH 미터와 전극을 검정하는 데에는 인증된 pH 값을 가지는 표준 완충용액을 사용하므로 표준 완충용액의 pH 값 정혹도는 실제 측정된 pH 값의 실효성을 제한할 수 있다. 본 연구에서는 정확한 pH의 측정을 위해서 pH 값을 인증할 수 있는 시스템을 구축하기 위한 제반의 연구를 수행하였으며, 이를 토대로 pH 1.6∼12.5의 범위에 해당하는 완충용액의 pH를 0.005 pH 단위 이내의 불확도로 인증하였다.

  • PDF

Analysis on Monopole Antenna for Moisture Determination in Oil Palm Fruit Using Finite Difference Method

  • Cheng, E.M.;Abbas, Z.;Rahim @ Samsuddin, H.A.;Lee, K.Y.;You, K.Y.;Hassan, J.;Zainuddin, H.;Khor, S.F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1754-1762
    • /
    • 2016
  • Finite difference analysis were applied to study the principle operation of monopole antenna for moisture determination in oil palm fruit at 2 GHz. The electromagnetic field interact with oil palm fruit on the interface between the antenna and oil palm fruit and cause a reflection. The reflection measurement is based on mismatch impedance or dielectric properties between two media. Reflection coefficient is used to quantify the level of reflection. The monopole antenna was made of RG405/U semi-rigid coaxial cable with an inner and outer diameter of 0.45 mm and 1.50 mm, respectively with 2.23 mm length of protruding conductor over 5.66 cm length of monopole antenna. This monopole antenna for moisture detection was compared with induced EMF method in terms of reflection coefficient at 2 GHz. The results show that the complex reflection coefficient measured using monopole antenna provides significant results to predict moisture content in oil palm fruit.

디지털 PI제어에 의한 브러시리스 직류모터의 안정도 향상 (The Stability Improvement of Brushless DC Motor by Digital PI Control)

  • 윤신용;백수현;김용;김철진;임태빈
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.38-46
    • /
    • 2000
  • 본 연구에서는 브러시리스 직류모터의 적합한 수학적 동가 모텔링을 구성하였으며 제어대상 BLOC 모터에 스 웹입력이 있는 상태로 역기전력의 측정에 의한 모터 파라미터를 측정하였다. 그리고 제시된 측정법의 타당성은 스템웅답의 실험결과에 의해서 확인하였다. 또한 훌센서로된 BLOC 모터의 오픈루프 전달함수로부터 얻은 근궤 적법의 결과에 따라 적합한 디지털제어기를 셜계하였으며 속도제어 가변을 위한 제어이득을 결정하였다. 여기서 수정된 Ziegler-Nichols의 동조법은 적합한 디지털 게인 설정을 위해서 적용되었으며 시스템의 안정성은 보드선 도와 실험으로 주파수영역의 해석에 의해서 입증하였다.

  • PDF

곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류) (Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow))

  • 임기원;최상류;정명균
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

변전소 주변 자계 실태조사 및 자계 특성이 이해증진 방안 (Survey on Magnetic Field around Substations and Proposals to Broaden Understanding of the Magnetic Field Characteristics)

  • 이성수;신현식
    • 한국전자파학회논문지
    • /
    • 제20권6호
    • /
    • pp.526-534
    • /
    • 2009
  • 본 논문은 전력공급설비 중 변전설비에서 발생하는 극저주파에 의한 자계의 실태를 조사하고 자계의 특성에 관한 이해증진 방안을 제시하는데 그 목적이 있다. 본고에서는 수도권 25개 변전설비를 중심으로 변전소 주변과 감사실 내부의 자계 수준을 IEC에서 제시하는 CISPR의 측정 방법(IEC/TC106 PT 62110)에 의거하여 변전설비에서 발생하는 자계를 측정하였다. 아울러 전력설비와 관련된 자계의 속성에 대한 정확한 이해를 위해 전자계 인증표시제와 같은 객관적이고 신뢰성 높은 정책적 접근방안을 제시한다.

기전력법을 이용한 용융 Zn-Cd 합금중 Zn의 활동도 측정 (Activity Measurement of Zn in Liquid Zn-Cd Alloy Using EMF Method)

  • 정성엽;정우광;박종진
    • 한국재료학회지
    • /
    • 제12권4호
    • /
    • pp.283-289
    • /
    • 2002
  • The E.M.F of the galvanic cell with fused salt was measured to determine the activities of zinc at 700-820K over the entire composition range of liquid Zn-Cd alloys. The cell used was as follows: (-) W | Zn(pure) $Zn^{2+}(KCI-LiCl)$ | Zn(in Zn-Cd alloy) | W (+) The activities of zinc in the alloys showed positive deviation from Raoult's law over the entire composition range. The activity of cadmium and some thermodynamic functions such as Gibbs free energy, enthalpy, entropy were derived from the results by the thermodynamic relationship. The comparison of the results and the literature data was made. The liquid Zn-Cd alloy is found to be close to the regular solution. The concentration fluctuations in long wavelength limit, $S_{cc}(o)$, in the liquid alloy was calculated from the results.

차량감지를 위한 이방성 자기저항센서 모듈의 설계 (Design of Anisotropic Magnetoresistance Sensor Module for Vehicle Detection)

  • 최학윤;이형일
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.99-105
    • /
    • 2011
  • This paper is about the design of 3-axis magnetic sensor module which detects parking and moving vehicle. For the sensor module, MR Sensor from Honeywell of which maximum measurement range is ${\pm}2$[G] is used. It also consisted of amplifier and sensor filter and fabricated $30{\times}50$[mm] PCB. Fabricated sensor module produced helmholtz coil of which the length is 1.2[m] of 3-axis to know the performance. It installed sensor module at the center and measured the detected magnetic field. In result, 3-axis were detected as 0.2~0.3[mG] and the drift of the fluctuation of magnetic field was stabilized at 0.03[mG] unit. For the performance evaluation of the vehicle detection, after the entry and parking of the vehicle, variation of magnetic field was measured as 0.323~0.695[G] which the average 0.5[G] of the earth magnetic field was the center and the range of variation was confirmed as 0.37[G]. Therefore, the designed magnetic sensor can be used as the vehicle detection sensor module.

소형 풍력발전용 영구자석형 동기발전기의 센서리스 제어 (Sensorless Control of PMSG for Small Wind Turbines)

  • 장석호;박홍극;이동춘;김흥근
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2009
  • 본 논문은 소형 풍력발전용 영구자석형 동기발전기에서 고정자 자속과 역기전력을 이용한 센서리스 제어방법을 제안한다. 기존의 다이오드와 DC-부스트 컨버터를 사용한 소형 풍력발전용 컨버터와는 달리 2-Leg 3상 PWM 컨버터를 사용하여 발전기를 구동한다. 이는 기존의 컨버터와 비교하여 가격적으로 뒤지지 않으며, 발전기의 벡터제어가 가능하여 최대출력 제어시 발전 효율향상을 확인할 수 있다. 그리고 센서리스 제어 알고리즘을 적용하여 속도 측정을 위해 사용되는 엔코더를 제거하므로 시스템의 가격을 저감시킨다. 제안된 알고리즘은 PSIM 시뮬레이션을 사용하여 컨버터 제어 성능과 발전기의 최대 출력 제어의 타당성을 검증한다.