• Title/Summary/Keyword: EMF Guideline

Search Result 8, Processing Time 0.02 seconds

Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline (공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석)

  • Shin, Hansu;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Measurement and Personal Exposure Assessment of Extremely Low Frequency(ELF) Electromagnetic Fields(EMF) (극저주파 영역에서의 전자파 노출에 관한 조사연구)

  • 김윤신;김수연;박지연;최원욱
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.55-61
    • /
    • 1997
  • This study was executed for the purpose of investigation of the EMFs exposures of personal and electronic environment. This study examines ELF-EMFs of electric appliances, subways and occupational and non-occupational human exposures, using EMDEX II (for 40 - 800Hz, Enertech Consultant, Inc.), from October 1995 to March 1996. Among the electric appliances examined, a massage unit showed the highest mean value of 247.07 $\mu$T, followed by an electric blanket of 5.24 $\mu$T. Indoor levels of EMF in subways exceerlcd 0.2 $\mu$T of the Swedish Guideline. The mean personal exposure levels of occupational group were 0.18 $\mu$T, while the personal EMF level of non-occupational group were 0.07 $\mu$T. Occupational group were exposed more highly while at work. However, the EMF levels during nonwork and sleep exposures between occuptional group and nonoccupational group were about the same. Estimates of time-intergrated exposure indicated that utility-specipic job classifications received about one-half or more of their total exposure on the job. Finally, this study would provide significant data for future research for exposure to magnetic fields, and more detailed study and research are necessary.

  • PDF

A Study on the Convenient EMF Compliance Assessment for Base Station Installations at a Millimeter Wave Frequency

  • Lee, Young Seung;Lee, Haeng-Seon;Choi, Hyung-Do
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.4
    • /
    • pp.242-247
    • /
    • 2018
  • This paper studies a convenient electromagnetic field (EMF) compliance assessment for base station installations at a millimeter wave (mmW) frequency. We utilize ray-tracing analysis as a numerical method for examining the wave propagation characteristic. Various installation cases are considered and the important parameters with a significant effect on the maximum power density levels are produced. We finally suggest the several scenarios for the convenient assessment of mmW base stations, which allow us to conduct cost effective computational tests compared with the current assessment procedure in the guideline.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Analysis for Measured Results in EMF Strength Exposure Level under Base Station Environment for Mobile Communication (이동 통신용 기지국 환경에서 전자파 강도 노출량 측정 결과 분석)

  • Song, Hae-Zu;Kim, Soon-Young;Lee, Moon-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.601-609
    • /
    • 2010
  • This paper measured EMF strength of the duty measurement radio station(77 station) and the non-duty measurement radio station(41 station) of mobile communication base station in Jeonbuk region. As the result of measurement, it generally reveals that EMF is highly low level compare to the human protection guideline. And It is regarded as level that the national people who live close to the mobile communication base station don't have to worry about electromagnetic wave. This paper provides comparative analyses categorized by the duty measurement station and the non-duty measurement station. The results reveals that the average value and the maximum value of the non-duty measurement station preferably was higher than all the duty measurement station. It is thought that the EMF exposure strength of the national people is caused by approach of station antenna rather than antenna power. Consequently this paper suggests that standard of the antenna power(exceed 30 W), standard of antenna height(exceed 10 m) specified by Radio Regulation Act enforcement ordinance, legal basis for mobile communication base station have to be changed.

Electromagnetic Fields in General Hospital (의료기관 내 전자파 환경)

  • Shin, Sei-One;Yun, Sang-Mo;Shin, Hyoun-Jin;Ahn, Hyun-Soo;Ahn, Hee-Deok
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF

Endonuclease G is Upregulated and Required in Testicular Germ Cell Apoptosis after Exposure to 60 Hz at 200 μT

  • Park, Sungman;Kim, Min-Woo;Kim, Ji-Hoon;Lee, Yena;Kim, Min Soo;Lee, Yong-Jun;Kim, Young-Jin;Kim, Hee-Sung;Kim, Yoon-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.142-150
    • /
    • 2015
  • Several reports supported that continuous exposure to 60 Hz magnetic field (MF) induces testicular germ cell apoptosis in vivo. We recently evaluated duration- and dose-dependent effects of continuous exposure to a 60 Hz MF on the testes in mice. BALB/c male mice were exposed to a 60 Hz MF at $100{\mu}T$ for 24 hours a day for 2, 4, 6, or 8 weeks, and at 2, 20 or $200{\mu}T$ for 24 hours a day for 8 weeks. To induce the apoptosis of testicular germ cell in mice, the minimum dose is $20{\mu}T$ at continuous exposure to a 60 Hz MF for 8 weeks, and the minimum duration is 6 weeks at continuous exposure of $100{\mu}T$. Continuous exposure to a 60 Hz MF might affect duration- and dose-dependent biological processes including apoptotic cell death and spermatogenesis in the male reproductive system of mice. The safety guideline of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) indicates that the permissible maximum magnetic flux density for general public exposure is $200{\mu}T$ at 60 Hz EMF (ICNIRP Guidelines, 2010). In the present study, we aimed to examine the expression of pro- and anti-apoptotic genes regulated by the continuous exposure to 60 Hz at $200{\mu}T$ in Sprague-Dawley rats for 20 weeks. The continuous exposure to 60 Hz at $200{\mu}T$ does not affect the body and testicular weight in rats. However, exposure to 60 Hz MF significantly affects testicular germ cell apoptosis and sperm count. Further, the apoptosis-related gene was scrutinized after exposure to 60 Hz at $200{\mu}T$ for 20 weeks. We found that the message level of endonuclease G (EndoG) was greatly increased following the exposure to 60 Hz at $200{\mu}T$ compared with sham control. These data suggested that 60 Hz magnetic field induced testicular germ cell apoptosis through mitochondrial protein Endo G.

Factors Affecting the Survivals of Out-of-hospital Cardiac Arrests by 119 Fire Service (119구급대원의 심폐소생술 성적 분석 - 병원전 심정지를 중심으로 -)

  • Kang, Byung-Woo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.111-128
    • /
    • 2005
  • Background: Cardiac arrest is one of the most critical diseases which can likely lead to severe cerebral disability or brain death when the cases can not recover their circulation within 10 minutes. Saving out-of-hospital cardiac arrest cases is a recent concern in Korea. Resuscitation has become an important multidisciplinary branch of medicine, demanding a spectrum of skills and attracting a plethora of specialities and organizations. The best survival can be achieved if all the following links have been optimized : rapid access, and early CPR, defibrillation and ACLS, Since the "Utstein Style" was advocated in 1991, many reports about out-of-hospital cardiac arrest have been published based on this guideline. These differences prevent valid inter-hospital and international comparisons. However, it is not known how effective resuscitation has become to the patients. In other words, there are no guidelines for reviewing, reporting, and conducting research on resuscitation in Korea. This dissertation aims to provide the basic data for a unified reporting guideline of resuscitation in Korea and evaluating the out-of-hospital factors associated with survival discharge of out-of-hospital cardiac arrest. Methods: As for this study, uses the collected data about Out-of-hospital cardiac arrests at 4 area, from January, 2005 to April. 2005. With a retrospective study, 174 cases were analyzed. The data was recorded based on the Out-of-Hospital Utstein Style. Results: Resuscitation was performed on 174 out-of-hospital cardiac arrest cases at the 4 area 14 patients(8.1%) recovered their spontaneous circulation. Overall, the ROSC of the out-of-hospital cardiac arrest patients was 8.1%, which was poorer than that of western countries. Gender distribution was 50 females(28.7%) and 124 males(71.3%), approximately twice as many males as females. ROSC of witnessed arrests was found out to be 97.7%. The ratio of the witnessed arrest groups showed higher results than that of unwitnessed arrest groups in the above-examined cases. Cardiac etiology consisted of cardiac(33.5%), non-cardiac(45.7%), trauma(20.1%), and unknown(6.0%). Cardiac was the best performance. Initial rhythm showed Ventricular Tachycardia/pulseless Ventricular Fibrillation in 8 patients(6.0%), asystole in 100(75.2%) and unknown in 25(18.8%). The results of the Ventricular Tachycardia/pulseless Ventricular Fibrillation showed higher results than the others cases, The proportion of the cardiogenic cause was 33.5%, which was only half of western countries. Ventricular Tachycardia/pulseless Ventricular Fibrillation is relatively rare. These differences were due to the prevalent pattern of Out-of-hospital cardiac arrest as well as prematurity of the EMSS. Bystander CPR was practiced on 13 patients(7.52%). ROSC was shown in 46.2% cases. CPR by EMT was carried out on 167 cases(96.5%). ACLS by EMf was rare. From collapse, 4 cases(2.6%) arrived to ED within 6 minutes. 13 (8.6%) within 10 minutes, and 49(32.5%) over 31 minutes. The sooner the patients arrived, the greater the ratio of ROSC and discharged alive became, and the same with collapse time to ROSC. As the results of the logistic regression analysis, ROSC was found out to be highly influenced by the time of ED arrival from collapse and Ventricular Tachycardia/pulseless Ventricular Fibrillation. Therefore, the ratio of ROSC depends on not any single factor but various intervention factors. Conclusion: This dissertation presents the following suggestions and directions of the study hereafter. First, the first step for a chain of survival should be taken to activate EMSS early with a phone as soon as cardiac arrests are witnessed. Second, it is keenly needed that emergency medical technicians should be increased through emergency education for living. Third, it is necessary to establish the emergency transportation system. Fourth, most of the Koreans have little understanding of EMT and the present operation systems have many problems, which should be fundamentally changed. Fifth, it is required to have an active medical control over Out-of-hospital CPR, And proper psychological supports should be given not only to patients themselves and their family but also individuals who are engaged in emergency situation. Finally, through studies hereafter on nationwide, comprehensive, and standard forms, it is needed to examine into the biological figures of human body, causes and trends of cardiac arrests, and then, to enhance the survival rate of Out-of-hospital cardiac arrests. Korean guidelines for Cardiopulmonary resuscitation need to be made.

  • PDF