• Title/Summary/Keyword: EMC Test

Search Result 130, Processing Time 0.027 seconds

Novel Design and Research for a High-retaining-force, Bi-directional, Electromagnetic Valve Actuator with Double-layer Permanent Magnets

  • You, Jiaxin;Zhang, Kun;Zhu, Zhengwei;Liang, Huimin
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • To increase the retaining force, a novel design for a concentric, bi-directional, electromagnetic valve actuator that contains double-layer permanent magnets is presented in this paper. To analyze the retaining-force change caused by the magnets, an equivalent magnetic circuit (EMC) model is established, while the EMC circuit of a double-layer permanent-magnet valve actuator (DLMVA) is also designed. Based on a 3D finite element method (FEM), the calculation model is built for the optimization of the key DLMVA parameters, and the valve-actuator optimization results are adopted for the improvement of the DLMVA design. A prototype actuator is manufactured, and the corresponding test results show that the actuator satisfies the requirements of a high retaining force under a volume limitation; furthermore, the design of the permanent magnets in the DLMVA allow for the attainment of both a high initial output force and a retaining force of more than 100 N.

Application of Transformation Electromagnetics to Cloak Design and Reduction of Radar Cross Section

  • Mittra, Raj;Zhou, Yuda
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.2
    • /
    • pp.73-85
    • /
    • 2013
  • In this paper we present an alternative approach to addressing the problem of designing cloaks for radar targets, which have been dealt with in the past by using the transformation optics (TO) algorithm. The present design utilizes realistic materials, which can be fabricated in the laboratory, and are wideband as well as relatively insensitive to polarization and incident angle of the incoming wave. The design strategy, presented herein, circumvents the need to use metamaterials for cloak designs that are inherently narrowband, dispersive and highly sensitive to polarization and incident angle. A new interpretation of the TO algorithm is presented and is employed for the design of radar cross section-reducing absorbers for arbitrary targets, and not just for canonical shapes, e.g., cylinders. The topic of performance enhancement of the absorbers by using graphene materials and embedded frequency structure surfaces is briefly mentioned. The design procedure for planar absorbing covers is presented and their performance as wrappers of general objects is discussed. A number of test cases are included as examples to illustrate the application of the proposed design methodology, which is a modification of the classical TO paradigm.

A Study on the SEU in the SRAM to proton Irradiation

  • Lho, Young-Hwan;Park, Bo-Kyun;Kim, Bong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2295-2297
    • /
    • 2003
  • The major problem encountered in satellite design is EMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility). Here, our focus is on the effects of protons on the electronic system. The SEU (Single Event Upset) results from the level change of stored information due to photon radiation and temperature in the space and the nuclear power plant environment. The impact of SEU on PLD (Programmable Logic Devices) technology is most apparent in ROM/SRAM/DRAM devices wherein the state of storage cell can be upset. In this paper, a simple and powerful test techniques is suggested, and the results are presented for the analysis and future reference. The test results are compared with that of JPL test report. In our experiment, the proton radiation facility available at KIRAMS (Korea Institute of Radiological Medical Sciences) has been applied on a commercially available SRAM manufactured by Hynix Semiconductor Company.

  • PDF

A Result of the Field Test for Regenerative Inverter (직류급전시스템의 에너지회생장치 적용을 위한 실계통 부설 시험)

  • Kim, Joo-Rak;Han, Moon-Seob;Jang, Dong-Uk;Kim, Jung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.286-293
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMC on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the developed inverter for regenerative power and its field test. Test result of developed inverter is presented.

  • PDF

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

BCI Probe Emulator Using a Microstrip Coupler (마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator)

  • Jung, Wonjoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) test is a method of injecting current into Integrated Circuit(IC) using a current injection probe to qualify the standards of Electromagnetic Compatibility(EMC). This paper, we propose a microstrip coupler structure that can replace the BCI current injection probe that is used to inject a RF noise in standard IEC 62132-part 3 documented by International Electrotechnical Commission. Conventional high cost BCI probe has mostly been used in testing automotive ICs that use high supply voltage. We propose a compact microstrip coupler which is suitable for immunity testing of low power ICs. We tested its validity to replace the BCI injection probe from 100 MHz to 1,000 MHz. We compared the power[dBm] that is needed to generate the same level of noise between current injection probe and microstrip coupler by sweeping the frequency. Results show that microstrip coupler can inject the same level of noise into ICs for immunity test with less power.

EMC 관련 최근 기술 동향 - CISPR 20 방사내성 Round Robin Test 결과 및 분석

  • Jang, Tae-Heon;Jo, Won-Seo
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.60
    • /
    • pp.48-52
    • /
    • 2006
  • 2006 CISPR 총회가 스웨덴 스톡홀름 KISTA에서 개최되었다. CISPR I 회의는 9월 18일부터 20일까지 3일간 WG2 및 WG4를 중심으로 진행되었으며, WG1과 WG3 회의는 9월 20일 오후에 있었다. 우리나라에서는 WG1에 두 가지 제안을 발표하였다. 하나는 2004년 중국 상해 회의에서 처음 제안하여 2005년 남아공 케이프타운 회의에서 Task Force가 구성된 대형 시험품에 대한 CISPR 20의 외부 방사내성 시험레벨에 관한 것이다. 2006년 1월 미국 산타페에서 열린 TF 회의에서 시험결과에 대한 기술적 토론이 있었으며, Round Robin Test(RRT)를 실시하기로 결정되었다. RRT시험은 7월 중순에 실시되었으며, 참여한 시험소는 영국의 SONY, 네덜란드의 Philips, 독일의 SHARP 이었으며, 국내의 여러 EMC 시험소도 추후에 참여하였다. RRT 시험의 결과 및 분석이 이번 스톡홀름 회의에서 발표되었다. 또한, CISPR 13의 방사성 방출(RE)의 측정거리 기준점의 변경에 관한 것이다. 본 고에서는 TV 수신기에 대한 RRT 시험결과 및 분석에 대한 발표 내용을 소개하고자 한다. CISPR 20의 외부 전자기장 내성 시험은 0.8 m인 개방형 스트립라인(Open Strip-line: OSL)내에 시험품을 설치하고 $150kHz{\sim}150MHz$에서 시험하도록 규정하고 있다. OSL에 설치할 수 없는 대형기기는 IEC 61000-4-3에 따라서 주파수 범위 $80MHz{\sim}150MHz$까지 동일한 한계치로 전자파무반사실에서 시험하도록 규정되어 있다. 이에 대해 국내 제조업체 및 EMC 전문가들로 구성된 CISPR I 국내 위원회에서는 IEC 61000-4-3에 의한 전자파무반사실(챔버)에서의 내성시험이 CISPR 20에 의한 OSL에서의 내성시험보다 가혹하다는 문제 제기가 있었다. 이것이 본 안건에 대한 배경이다 지금까지 진행되어 왔던 내용을 요약해 보면 2004년 상해 회의에서, 수치해석 및 측정비교를 통하여 CISPR 20에서 규정하고 있는 OSL 전기장 교정방법의 개선의 필요성과 OSL에서 시험할 수 없는 대형 시험품에 대하여 시험레벨을 조정할 것을 지적하였다. 2005년 케이프타운 회의에서는 실제적으로 TV 방송 수신기 및 관련기기가 두가지 방법으로 시험되었을 때 시험결과에 미치는 영향을 시험품의 전기장 내성 레벨로 비교하였으며, 전자파무반사실에서 시험할 경우 시험레벨이 12 dB 낮추도록 보정되어야 할 것을 제안하였다. 2006년 이번 회의에서는 세계 각국의 시험소와 비교시험을 통하여 나타난 OSL과 전자파무반사실 간의 시험결과의 차이 및 이에 대한 원인을 분석하여 보고하였다. OSL과 전자파무반사실 비교시험에서 나타난 차이는 평균적으로 9 dB의 차이로 나타났으며, 주요 원인은 OSL에서 적용하고 있는 시험품을 OSL내부에 설치한 후 시험품에 의해 변경된 전기장의 세기를 보정해 주는 인자(k2)로 인한 차이(6 dB)와 OSL 내부의 전기장의 세기와 전자파무반사실 균일장 영역의 전기장의 세기의 차이(3 dB)이다.

A Study on Electromagnetic Compatibility Performance Evaluation of Power Conditioning System for Residential Fuel Cell (가정용 연료전지 전력변환장치 전자파적합성 성능 평가 연구)

  • Choi, Young-Joo;Nam, Tae-Ho;Lee, Eun-Kyung;Lee, Duk-Gwon;Lee, Jung-Woon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.23-29
    • /
    • 2017
  • Solar and wind energy among the renewable energy produce irregular power because resource is difficult to control. When connected to grid have unstable. However, when the fuel cell system is connected to grid more stable because regular frequency and output power based on controllable hydrogen energy. To using fuel cell system in the household, it is important that the safety performance of power conditioning system(PCS) and it is important that evaluation method of electromagnetic compatibility(EMC). In this study, we consider that introduce power-frequency magnetic field immunity test before analyzed that compare with the EMC of the international standards and KGS AB 934 PC53. Also, we conduct that actual assessment and study on available the quantitative analysis as using complementary indicator.

The Flight Test of the KSLV-I Electronic Systems Using a Light Airplane (경항공기를 이용한 KSLV-I 전자탑재장비 비행시험)

  • Ji, Ki-Man;Lee, Soo-Jin;Chung, Eui-Seung
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.142-150
    • /
    • 2008
  • In order to ensure the individual and mutual performances among the telemetry system, tracking system, flight termination system, GPS, and inertial navigation & guidance system which are installed in the KSLV-I 2nd stage and ground equipment of the Naro space center, flight test using a light airplane is required. Since the high degree of test efficiency is fulfilled through the minute plan and analysis about selection of the equipment which are applicable to the test, harness, operation strategy, and antenna installation. KSLV-I communication environment and flight profile should be precisely taken into account during the flight test. In this document, overall aspect of the KSLV-I 2nd stage equipment specification, a rack for the installation, harness, the airplane specification, and flight route which are required for the effective flight test are presented.

  • PDF

The Implementation of Testing Board forSingle Event Upsets

  • Lho, Young-Hwan;Kim, Ki-Yup
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.2
    • /
    • pp.28-34
    • /
    • 2004
  • One of the major problem encountered in nuclear plants and satellites design isEMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility).Here, our focus is to implement the test board for checking SEU (Single EventUpsets); the effects of protons on the electronic system. The SEU results from thelevel change of stored information due to photon radiation and temperature in thespace environment. The impact of SEU on PLD (Programmable Logic Devices)technology is most apparent in ROM/SRAM/DRAM devices wherein the state ofstorage cell can be upset. In this paper, a simple and powerful test techniques issuggested, and the results are presented for the analysis and future reference. In ourexperiment, the proton radiation facilitv (having the energy of 50 MeV with a beamcurrent of 60 uA of cyclotron) available at KIRAMS (Korea Institute of RadiologicalMedical Sciences) has been applied on a commercially available SRAM manufacturedby Hynix Semiconductor Company.