• Title/Summary/Keyword: EM analysis

Search Result 550, Processing Time 0.039 seconds

A Study on Manufacturing of Sample Holder for the EM Property Analysis in W-band (W-band 전파특성 분석용 샘플홀더 제작에 관한 연구)

  • Choi, Chang-Mook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.6
    • /
    • pp.1397-1403
    • /
    • 2011
  • In this paper, fabrication of sample holder was studied for an analysis of electromagnetic(EM) wave property in W-band(75 GHz~110 GHz). First of all, a propagation theory of EM wave was considered in the rectangular waveguide, and measurement technique was suggested for analysis of characteristics. A sample holder using in W-band was designed and fabricated, and used for analysis of material property and absorption ability using RAM samples. As a result, the sample holder test was verified exactly for measuring EM wave property of RAM sample. In the future, the proposed sample holder would like to be used for the EM wave property analysis in W-band.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

The Optimization using PCB EM interpretation of GEO satellite's L Band Converter (정지궤도위성용 L대역변환반의 PCB EM 해석을 통한 최적화)

  • Kim, Ki-Jung;Ko, Hyeon-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1219-1226
    • /
    • 2013
  • This study is the analysis and verification process of the L-band satellite communications repeater thought PCB & circuit EM analysis. System performance can be vulnerable to various spurious inside the L-band satellite transponder, power conversion board, digital signal board, TM/TC board, such as control panels and blocks that are linked signal components when the winch is increased due to the noise component. So the whole system can cause performance degradation. PCB resonance analysis and EM simulation can be easily analyzed for a variety of optimal. Also, by setting the ports on the PCB, H/W designer wants to can easily analyze system.

Analysis of Soil Properties in a Rice Field Using Small Loop EM Method (소형루프 전자탐사에 의한 논 토양분석)

  • Yong Hwan-Ho;Song Sung-Ho;Kim Jin-Ho;Cho In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.207-214
    • /
    • 2003
  • To analyze soil properties with depth in rice field, we compared resistivity distributions obtained from soil analysis with one dimensional inversion of small loop electromagnetic (EM) data. Although it didn't show consistency exactly between the two resistivity distributions, low resistivity zones in soil analysis, appeared to agree with low resistivity zones in EM result. Therefore, small loop EM method can be applied to obtain rapidly the soil properties such as salt accumulation in a rice field. If research on soil property and EM responses of unsaturated zone would be conducted consistently, small loop EM method can be used effectively to detect salt accumulated zone in agricultural area.

New EM algorithm for Principal Component Analysis (주성분 분석을 위한 새로운 EM 알고리듬)

  • 안종훈;오종훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.04b
    • /
    • pp.529-531
    • /
    • 2001
  • We present an expectation-maximization algorithm for principal component analysis via orthogonalization. The algorithm finds actual principal components, whereas previously proposed EM algorithms can only find principal subspace. New algorithm is simple and more efficient thant probabilistic PCA specially in noiseless cases. Conventional PCA needs computation of inverse of the covariance matrices, which makes the algorithm prohibitively expensive when the dimensions of data space is large. This EM algorithm is very powerful for high dimensional data when only a few principal components are needed.

  • PDF

A Study on FDTD Analysis and Fabrication of the Sheet-type Millimeter EM wave Absorber

  • Kim, Dae-Hun;Soo, Dong-Soo;Kim, Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2010
  • In this paper, the EM wave absorber was developed for the 94-GHz detecting radar system. To analysis an EM wave absorber in millimeter wave band, we fabricated three absorber samples using carbon black and titanium dioxide and permalloy with chlorinated polyethylene. After measuring the complex relative permittivity, the absorption characteristics are simulated by 1D FDTD according to different thicknesses of less than 1.0 mm. Then, the EM wave absorber was fabricated based on the FDTD simulation. As a result, the measured results agreed well with the simulated ones, and the developed EM wave absorber with a thickness of 0.7 mm had the desired absorption characteristics of more than 14 dB in the frequency range of the 94-GHz band.

A Study on Automation Process Based on WEB for Circuit and PCB EM Analysis (회로해석 및 PCB 전자장 분석을 위한 웹 기반 자동화 프로세스에 관한 연구)

  • Lee, Jang-Hoon;Jang, Suk-Hwan;Jeung, Seung-Il;Lee, Seung-Yo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1716-1721
    • /
    • 2014
  • In this paper, a study on automation method for the circuit/EM (Electro-Magnetic) simulation is carried out to analyze effectively the SI/PI (Signal Integrity/Power Integrity) issues which occur on circuits and/or PCBs (Printed Circuit Boards). For the automation of the circuit/EM simulation, algorithms performing each process of the SI/PI analysis automatically (such as ports setup, circuit definition and SI/PI evaluation) are developed; thereby automation system for the SI/PI analysis is constructed with the algorithms. The automation of the circuit/EM simulation is accomplished in the environment of the C/S (Client/Server) architecture in order to reduce resources such as high cost computers demanded for the SI/PI analysis. The automation method for the SI/PI analyses proposed in this paper reduces effort, time, and cost spent on the environment setup for simulation and the SI/PI analysis process. In addition, the proposed method includes automation of the documenting process, which organizes, records and displays the SI/PI analysis results automatically for users.

Toxicological Study on the Water Extract of Symphytum officinale L. in Rats (흰쥐에 있어서 Symphytum officinale L. 추출액의 독성에 관한 연구)

  • 방형애;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.2
    • /
    • pp.141-152
    • /
    • 1997
  • This study was performed to investigate the toxic effect of pyrrolizidine alkaloids from symphytum officinale i n rat. For this experiment, 120 male and female rats of Sprague-Dawley strain were used. The experimental groups were divided into five: Group CM and CF served as normal control with its gender. Group EM1 and EF1 were fed a 1% Symphytum officinal extract diet for 8 weeks. Group EM2 and EF2 fed a diet containing 2% extract diet. 4% extract diet into group EM3 and EF3 and 8% extract diet into group EM4 and EF4 were given. The results were as follows: 1. The major alkaloids of Symphytum officinale extract were symphytine, echmidine, and lasiocarpine. The amounts of total alkaloid were 168 $\mu\textrm{g}$ PAs/$m\ell$ extract. And contents of Pas in leaves were 0.05% wt.. 2. Total serum bilirubin concentrations increased significantly in group EM2, EM3, and EM4. Group EF1, EF2, EF3, and EF4 showed statistical significance for the group CF (p<0.05). 3. Aspartate transaminase activities were increased significantly in group EM3 and EM4 (p<0.05). Aspartate transaminase activities of EF1, EF2, EF3, and EF4 showed statistical significance for the group CF (p<0.05). 4. Alanine transaminase activities increased significantly in group EM3, EM4 (p<0.05). Alanine transaminase activities of EF1, EF2, EF3, and EF4 showed statistical significance for the group CF (p<0.05). 5. Alkaline phosphatase activities increased significantly in group EM2, EM3, and EM4 (p<0.05). Alkaline phosphatase activities of EF1, FE@, EF3, and EF4 showed statistical sigmificance for the group CF (p<0.05). 6. istopathological analysis of liver specimens from group EM3 and EM4 showed focal necrosis, periportal necrosis and apoptpsis. Hepatocytes obtained from group EM2 showed fatty change and hydropic degeneration in group EM3 and EM4. Chromatolysis and chromatin margination was shown in group EF2 and EF3. With the above results, it was demonstrated that the Symphytum officinal extract could induce functional change of liver, and histopathological change of liver in rats fed a diet containing extract. In conclusion, because of the risk of intoxication or adverse effect, the composition, dosage and mode of administration of herbal products should be monitored strictly. And this study serves as a reminder that herbal as well as orthodox medications may have serious side effects.

  • PDF

Workflow of Cryo-Electron Microscopy and Status of Domestic Infrastructure

  • Choi, Ki Ju;Shin, Jae In;Lee, Sung Hun
    • Applied Microscopy
    • /
    • v.48 no.1
    • /
    • pp.6-10
    • /
    • 2018
  • Cryo-electron microscopy (cryo-EM) allows the analysis of the near-native structures of samples such as proteins, viruses, and sub-cellular organelles at the sub-nano scale. With the recent development of analytical methods, this technique has achieved remarkable results. The importance of cryo-EM gained wide recognition due to last year's award of the Nobel Prize in Chemistry. To help promote the knowledge of this technique, this paper introduces the basic workflows of cryo-EM and domestic cryo-EM service institutes.

A Study on the efficiency of the MCMC multiple imputation In LDA (선형판별분석에서 MCMC다중대체법의 효율에 관한 연구)

  • Yoo, Hee-Kyung;Kim, Myung-Cheol
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.189-198
    • /
    • 2009
  • This thesis studies two imputation methods, the MCMC method and the EM algorithm, that take care of the problem. The performance of the two methods for the linear (or quadratic) discriminant analysis are evaluated under various types of incomplete observations. Based on simulated experiments, the effect of the imputation using the EM algorithm and the MCMC method are evaluated and compared in terms of the probability of misclassification and the RMSE. This is done for the various cases of incomplete observations. The cases are differentiated by missing rates, sample sizes, and distances between two classification groups. The studies show that the probability of misclassification and the RMSE of the EM algorithm method is lower than the MCMC method. Therefore the imputation using the EM algorithm is more efficient than the MCMC method. And the probability of misclassification of the method that all vectors of observations with missing values are omitted from analysis is lower than the EM algorithm and the MCMC method when the samples size is small and the rate of missing values is extremely big.