In the present study, quids from La Cueva de los Muertos Chiquitos (CMC) were subjected to ELISA tests for 2 protozoan parasites, Toxoplasma gondii (n=45) and Trypanosoma cruzi (n=43). The people who occupied CMC, the Loma San Gabriel, lived throughout much of present-day Durango and Zacatecas in Mexico. The known pathoecology of these people puts them into at-risk categories for the transmission of T. gondii and T. cruzi. Human antibodies created in response to these 2 parasites can be detected in modern saliva using ELISA kits intended for use with human serum. For these reasons, quids were reconstituted and subjected to ELISA testing. All test wells yielded negative results. These results could be a factor of improper methods because there is no precedence for this work in the existing literature. The results could equally be a simple matter of parasite absence among those people who occupied CMC. A final consideration is the taphonomy of human antibodies and whether or not ELISA is a sufficient method for recovering antibodies from archaeological contexts. An additional ELISA test targeting secretory IgA (sIgA) was conducted to further examine the failure to detect parasite-induced antibodies from quids. Herein, the methods used for quid preparation and ELISA procedures are described so that they can be further developed by future researchers. The results are discussed in light of the potential future of quid analysis.
Processed foods containing pork fat tissue to improve flavor and gain economic benefit may cause severe issues for Muslims, Jews, and vegetarians. This study aimed to develop an indirect enzyme-linked immunosorbent assay (iELISA) based on a monoclonal antibody specific to thermal stable-soluble protein in pork fat tissue and apply it to detect pork fat tissue in heat-processed (autoclave, steam, roast, and fry) beef meatballs. To develop a sensitive iELISA, the optimal sample pre-cooking time, coating conditions, primary and secondary dilution time, and various buffer systems were tested. The change in the iELISA sensitivity with different 96-well microtiter microplates was confirmed. The detection limit of iELISA performed with an appropriate microplate was 0.015% (w/w) pork fat in raw and heat-treated beef. No cross-reactions to other meats or fats were shown. These results mean that the iELISA can be used as an analytical method to detect trace amounts of pork fat mixed in beef.
A simple and rapid ELISA (enzyme-linked immunosorbent assay) system for fumonisins, a group of potentent carcinogen, was developed. To produce anti-fumonisin B1 (FB1) antibodies, FB1 conjugated to keyhole lympet hemocyanin (KLH) and Freund's adjuvant were immunized into rabbits subcutaneously 3 times. From one of the antisera showing high titer and good competition with the toxin in ELISA, polyclonal antibodies were purified. The cross-reactivities of the antibodies against fumonisin $B_1,\;B_2\;and\;B_3$ were 100%, 69%, and 166%, respectively. When competitive direct ELISA established by use of the antibody was applied to the spike test of $FB_1$ onto uncontaminated corns, the assay recovery was unstable unless 75% methanol extracts of corn were diluted to 1/100 with buffer. In that condition the mean ELISA recovery of FB1 from corns spiked $1-30\;{\mu}g/g$ was 67% and stable (coefficient of variation (CV) of each recovery percentage, 3.4%). The results suggest that the ELISA system established in this study needs no cleanup procedure and therefore would be powerful to screen a large number of corn samples contaminated with fumonisins.
In order to develop enzyme-linked immunosorbent assay (ELISA) for fumonisins, production of specific antibodies, establishment of ELISA conditions, and quantitation of the toxin from spiked corns by ELISA were performed. Fumonisin $B_1(FB_1)$ conjugated to cholera toxin (CT) with or without Freund's adjuvant was subcutaneously injected into 2 groups of rabbits. When the titer of the antisera produced by each rabbit was tested, higher titer was observed in case of the immunization with the adjuvant. By use of the antiserum showing the highest titer (1:16,000) and its purified antibodies, competitive indirect and direct ELISA's (ciELISA and cdELISA) were established, respectively. When the cross-reactivity of the antibody against fumonisin analogs was investigated by the ciELISA, it was very low against $B_3$ (2%) but high against fumonisin $B_2$ (179%). The sensitivity of the ELISAs was also very high, because the detection limit for $FB_1$ was 0.03 ppb in ciELISA and 0.3 ppb in cdELISA. When the ELISA's were applied to the spiked corns after extraction with 75% methanol, the assay recovery of $FB_1$ was too unstable to assay. However, when cleanup by strong anion exchange (SAX) cartridge was introduced to remove interfering materials, the mean ELISA recovery of $FB_1$ from corns spiked to 3~10 ppm was found to be 34.0% and stable (mean of CV, 8.2%).
An enzyme-linked immunosorbent assay(ELISA) was developed for the detection of milk proteins in processed foods. The ${\alpha}_{s1}-casein({\alpha}_{s1}-CN)$, a heat stable major milk protein, was immunized into rabbits to produce specific antibodies. When competitive indirect ELISA(ciELISA) using $anti-{\alpha}_{s1}-CN$ antibodies was established, its detection limit was $0.1\;{\mu}g/mL$. The reactivities of the specific antibodies toward ${\alpha}_{s1}-CN$, skim milk, ${\beta}-CN$ and whey protein isolate(WPI) were 100, 37, 0.14 and 0.04%, respectively, as determined by ciELISA. However $anti-{\alpha}_{s1}-CN$ antibodies did not have any reactivity to other milk proteins such as ${\beta}-lactoglobulin,\;{\alpha}-lactalbumin$, bovine serum albumin, and isolated soy protein. When sandwich ELISA was established, its detection limit was $0.01\;{\mu}g/mL$ which was 10 times more sensitive than that of ciELISA. In the spike test which was performed by adding 1-10% of whole CN to market milk, mean assay recovery as determined by sandwich ELISA was 94.8%(CV, 8.2%). Food stuffs and dairy products were assayed by sandwich ELISA to show 29, 0.13, 0.25, and 6.9% of whole CN in skim milk powder, WPI, semi-solid yoghurt, and processed cheese, respectively.
A simple and rapid detection system for $aflatoxin\;M_1\;(AFM_1)$ in cow's milk by an enzyme-linked immunosorbent assay (ELISA) was developed. Specific antibodies against $AFM_1$, conjugated to bovine serum albumin $(AFM_1-BSA)$ were raised in rabbits and purified. The cross-reactivities of the antibodies against aflatoxin analogs were less than 29.9%. When a competitive direct ELISA (cdELISA) for $AFM_1$, established by use of the antibodies was applied to the spike test of $AFM_1$ onto uncontaminated cow's milk, the assay recovery was unstable unless cow's milk was diluted to 40% (2:3) with phosphate buffered saline (PBS). In that condition of sample dilution, the mean ELISA recovery of $AFM_1$, from the cow's milk was 113% (coefficient of variation (CV) of each recovery percentage, 8.2%) in the range of $0.3{\sim}3.0\;ppb$. These results showed that the ELISA system could be a convenient tool to monitor the contamination of AFM1 more than 0.5 ppb in cow's milk (FDA allowance limit) easily.
There have been few studies related to ELISA for mackerel. In this study we developed a sandwich ELISA for mackerel in processed foods using rabbit polyclonal antibodies against mackerel parvalbumin, the major allergen of mackerel and heat-stable protein. The parvalbumin was purified by ammonium sulfate precipitation and Sephadex G-50 column chromatography. From the standard ELISA curves, the detection limit of parvalbumin was 3 ng/mL and the detection range of mackerel was 5-5,000 ${mu}g/mL$. We further investigated the cross-reactivity of the antibodies toward mackerel, mackerel pike, salmon, flatfish, armorclad rockfish, cod fish, squid, shrimp, blue crab, and lobster. The antibodies were specific for mackerel only. The mean assay recoveries in cooked cream soup, baby food, sausage, and sauce spiked with 0.01 to 0.3% mackerel were 104, 101, 54, and 0%, respectively. In sample tests of 16 commercial items, the qualitative coincidence ratio of assay result and indication was 75%.
Enzyme-linked immunosorbent assay (ELISA) was developed to detect rotavirus antigen in fecal samples using VP6-specific monoclonal antibody(2B12). The ELISA for rotavirus antigen detection found to have specificity to all bovine and porcine rotaviruses tested but not to bovine viral diarrhea virus and bovine coronavirus. The ELISA appeared to have similar sensitivity and specificity compared to fluorescence antibody assay(FA) and electropherotyping (PAGE).
Agar-gel Diffusion test (AGD), Counterimmunoelectrophoresis(CIEP) and Enzyme-Linked Immunosorbent Assay(ELISA) were examined with the sera of skin test positives for paragonimiasis. The crude antigen (Paragcnimus whole worm extracts: protein concentration, 7.56mg/m1) and human sera were used in AGD and CIEP. And in ELISA test, diluted antigen with 1:40, 000 of crude antigen and diluted sera with 1:100, 1:200 were used in the test. The positive identical ratio between AGD and CIEP reactions is 985 and negative identical ratio is 100%. One or three precipitin bands are observed in AGD. One to seven precipitin bands are also revealed in CIEP. Especially, deeply stained bands are observed in CIEP than those of AGD. The positive identical ratios between AGD and ELISA tests are 96% in 1:100 diluted sera, and 94% in 1:200 diluted sera. But the negative identical ratios between AGD and ELISA tests are 97% and 99% respectively in 1:100 and 1:200 diluted sera. The positive identical ratios between CIEP and ELIEA tests are 98% and 96% respectively in 1:100 and 1:200 diluted sera, but also 97% and 99% in 1:100 and 1:200. Control sera, such as clonorchiasis, amoebiasis and toxoplasmcsis, revealed all negatives with Paragonimus antigen in AGD, CIEP and ELISA tests. By above results, ELISA was mcst sensitive, next CIEP and AGD, But AGD test apprars to be more useful when used to crude antigen without cross rfacticn with other parasitic infections. CIEP test is basically equal in terms of precipitin reaction, but CIEP is able to be detected more sensitively and rapidly though less simple in handiwork than AGD. Consequently, three methods for inlmunological tests of paragonimiasis have gccd correlations with one another. Also, each of these has both merits and demerits in iymunolcgical test for paragonimiasis. But the ELISA test was proved to be the most sensitive and convenient tool for mass screening test, especially in cacti of using purified antigen.
Kim, S.C.;Lee, K.S.;Kim, Y.K.;Kim, C.K.;Choi, K.H.;Kwon, O.J.;Kim, J.B.
Clinical and Experimental Reproductive Medicine
/
v.17
no.1
/
pp.71-80
/
1990
New immunoassay systems for the detection of anti-sperm antibodies were developed. For this, sperm surface protein was purified by the immunoaffinity column prepared by the coupling of rabbit anti-human IgG antibodies to Sepharose-4B. Fraction eluted by tris-HCI buffer containing SDS showed a single band having molecular weight of about 60KD on electrophoresis. Enzyme HRP labelled goat anti-human IgG and chemiluminescence aminobutylethyl-isoluminol(ABEI) labelled rabbit anti-human IgG were used for ELISA and CIA, respectively. These two labelled conjugate bound well with human IgG. When serum dilution curves were made to titrate positive serums, two kinds of curves with steep and sluggish slopes were obtained Serum samples were categorized into 3 groups: positive, weak positive and negative based on slope of curve and O.D. values at 1:160 dilution of serum. When ELISA and CIA were compared to conventional method Kibrick test by the determinations of 62 male serums with different diagnosis, the results of ELISA and CIA agreed well, but both disagreed with that of Kibrick test. This study showed that purified sperm surface antigen can be used to develope solid-phase immunoassay systems such as ELISA and CIA which may eliminate the problems encounted the immobilization of living sperm in other tests.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.