• Title/Summary/Keyword: ELISA method

Search Result 593, Processing Time 0.029 seconds

Identification of a conservative site in the African swine fever virus p54 protein and its preliminary application in a serological assay

  • Xu, Lingyu;Cao, Chenfu;Yang, Zhiyi;Jia, Weixin
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.55.1-55.12
    • /
    • 2022
  • Background: ASF was first reported in Kenya in 1910 in 1921. In China, ASF spread to 31 provinces including Henan and Jiangsu within six months after it was first reported on August 3, 2018. The epidemic almost affected the whole China, causing direct economic losses of tens of billions of yuan. Cause great loss to our pig industry. As ELISA is cheap and easy to operate, OIE regards it as the preferred serological method for ASF detection. P54 protein has good antigenicity and is an ideal antigen for detection. Objective: To identify a conservative site in the African swine fever virus (ASFV) p54 protein and perform a Cloth-enzyme-linked immunosorbent assay (ELISA) for detecting the ASFV antibody in order to reduce risks posed by using the live virus in diagnostic assays. Method: We used bioinformatics methods to predict the antigen epitope of the ASFV p54 protein in combination with the antigenic index and artificially synthesized the predicted antigen epitope peptides. Using ASFV-positive serum and specific monoclonal antibodies (mAbs), we performed indirect ELISA and blocking ELISA to verify the immunological properties of the predicted epitope polypeptide. Results: The results of our prediction revealed that the possible antigen epitope regions were A23-29, A36-45, A72-94, A114-120, A124-130, and A137-150. The indirect ELISA showed that the peptides A23-29, A36-45, A72-94, A114-120, and A137-150 have good antigenicity. Moreover, the A36-45 polypeptide can react specifically with the mAb secreted by hybridoma cells, and its binding site contains a minimum number of essential amino acids in the sequence 37DIQFINPY44. Conclusions: Our study confirmed a conservative antigenic site in the ASFV p54 protein and its amino acid sequence. A competitive ELISA method for detecting ASFV antibodies was established based on recombinant p54 and matching mAb. Moreover, testing the protein sequence alignment verified that the method can theoretically detect antibodies produced by pigs affected by nearly all ASFVs worldwide.

A comparison of agglutination tests and enzyme-linked immunosorbent assay for the bovine brucellosis (소 브루셀라병 혈청 항체가 응집반응 비교 시험)

  • Kim, Cheol-Ho;Bang, Sang-Young;Jeon, Jae-Hyung;Bhak, Jong-Sik;Lee, Min-Kwon;Shin, Jung-Sub
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.315-329
    • /
    • 2008
  • A total of 710 bovine serum samples which are composed 532 bovine serum samples showed negative reaction and 178 bovine serum samples showed positive reaction with tube agglutination test (TAT) from North area of Gyeong-nam, Korea were tested using all the 3 assays which are Rose-Bengal test(RBT), tube agglutination test (TAT) and enzyme-linked immunosorbent assay (ELISA, two types) and analyzed for evaluation of specificity, sensitivity, reproducibility and predictive value. In the comparison of serum antibody titer agglutination test, RBT showed almost agreement with TAT. In the comparison of TAT and two types of ELISA method, they showed difference in specificity and sensitivity about 5%. But there is no significant difference in detecting sensitivity between two types of ELISA method and TAT. In serologic tests for bovine brucellosis, the new assay ELISA would be a good candidate for serologic survey for bovine brucellosis in Korea because it is efficient in detecting many test samples quickly. But the serum agglutination tests (RBT, TAT) are more economical and easy assay for detection. In the test of comparison of antibody titer between first day of finding and 10 days after finding by TAT, there was no change in 55% (76/139) of positive cattle.

Development of an Enzyme-Linked Immunosorbent Assay for the Iletection of Aflatoxin $B_1$ (Aflatoxin $B_1$의 검출을 위한 효소면역측정법의 개발)

  • 손동화;박애란;서병철;김진철;이인원;남영중;허우덕
    • Microbiology and Biotechnology Letters
    • /
    • v.20 no.2
    • /
    • pp.225-232
    • /
    • 1992
  • In order to develop an enzyme-linked immunosorbent assay(ELISA) for detecting aflatoxin $B_1(AFB_1)$, we produced and purified antibodies, thereafter established and evaluated methods of direct and indirect competitive ELISA. Anti-AFB, antisera, produced by immunizing rabbits with $AFB_1$-1-(0-carboxymethy1)oxime-bovine serum albumin conjugate ($AFB_1$-BSA), were removed of anti-BSA antibodies by quantitative precipitation reaction and further purified by ammonium sulfate precipitation and DEAE-Sephadex A-50 ion exchange chromatography. Purified IgG fractions were used as anti-$AFB_1$ antibodies. The antibodies, whose titer was deterrnined extremely high above $2 \times 10^6$, showed low cross-reactivity of 3~34% against $AFB_1$ analogues such as G2, B2, and GI. From the standard curves of direct and indirect competitive ELISA for AFBI, the detection ranges were found 0.2~20 and 1~10, 000 ng/ml(ppb) respectively. In their sensitivity, stability, simplicity, and rapidity, the direct method was more suitable than the indirect method for practical use.

  • PDF

The anti-allergic effect of SESHINGO(SSG) (세신고가 알레르기성 비염에 미치는 효과)

  • Kim, Min-Ae;Kim, Mi-Bo;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.3
    • /
    • pp.69-81
    • /
    • 2008
  • Objective : The purpose of this study was find out the anti-allergic effects of SESHINGO on the allergic rhinitis. Methods : Cell viability was evaluated by the MTT assay. Cells were treated with the indicated concentration of SSG. $TNF-\alpha$ concentration was measured from cell supernatants using ELISA method. IL-4 concentration was measured from cell supernatants using ELISA method.$IFN-\gamma$ concentration was measured from cell supernatants using ELISA method. Total RNA was isolated, $TNF-\alpha$ and IL-4 mRNA expression was detected by RT-PCR analysis Total RNA was isolated, COX-1, COX-2 mRNA was analyzed by RT-PCR analysis. Results : 1. $\beta$-hexosaminidase release in RBL-2H3 cells were decresed by SESHINGO attentively. 2. Secreting ration of $TNF-\alpha$was restrained in RBL-2H3 cells by SESHINGO attentively. 3. Secreting ration of IL-4 was restrained in RBL-2H3 cells by SESHINGO attentively 4. Revelation of $TNF-\alpha$ mRNA was decresed in RBL-2H3 cells as concetration. 5. Revelation of.IL-4 mRNA was decresed in RBL-2H3 cells as concetration. 6. Revelation of COX-2 mRNA was decresed in RBL-2H3 cells. Conclusion : According to above results, to evaluate the effect of SSG on the anti-allergic effects.

  • PDF

Antigenicity of Protein Entrapped in Poly(lactide-co-glycolide) Microspheres (폴리락티드-글리콜리드 마이크로스피어에 봉입된 단백질의 항원성 평가)

  • Song, Seh-Hyon;Cho, Seong-Wan;Shin, Taek-Hwan;Yoon, Mi-Kyoung;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.3
    • /
    • pp.191-196
    • /
    • 2001
  • Biodegradable polymeric microspheres were studied for their usefulness as carriers for the delivery of vaccine antigens. However, protein antigen could be denatured during microencapsulation processes due to the exposure to the organic phase and stress condition of cavitation and shear force. Therefore this study was carried out to re-evaluate the degree of protein denaturation during microencapsulation with poly(lactide-co-glycolide) (PLGA) copolymer. PLGA microspheres containing ovalbumin (OVA), prepared by W/O/W multiple emulsification method, were suspended in pH 7.4 PBS and incubated with shaking at $37.5^{\circ}C$. Drug released medium was collected periodically and analyzed for protein contents by micro-BCA protein assay. In order to evaluate the protein integrity, release medium was subjected to the analyses of SDS-PAGE and size exclusion chromatography (SEC). And enzyme-linked immunosorbent assay (ELISA) was introduced to measure the immunoreactivity of entrapped OVA and to get an insight into the three-dimensional structure of epitope. The structures of entrapped protein were not affected significantly by the results of SDS-PAGE and SEC. However, immunoreactivity of released antigen was varied, revealing the possibility of protein denaturation in some microspheres when it was evaluate by ELISA method. Therefore, in order to express the degree of protein denaturation, antigenicity ratio (AR) was obtained as follows: amount of immunoreactivity of OVA/total amount of OVA released ${\times}100(%)$. ELISA method was an efficient tool to detect a protein denaturation during microencapsulation and the comparison of AR values resulted in more accurate evaluation for immunoreactivity of entrapped protein.

  • PDF

Nested-PCR and a New ELISA-Based NovaLisa Test Kit for Malaria Diagnosis in an Endemic Area of Thailand

  • Thongdee, Pimwan;Chaijaroenkul, Wanna;Kuesap, Jiraporn;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.4
    • /
    • pp.377-381
    • /
    • 2014
  • Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

Development of ELISA System for Screening of Specific Binding Inhibitors for Src Homology (SH)2 Domain and Phosphotyrosine Interactions

  • Lee, Sang-Seop;Lee, Kyung-Im;Yoo, Ji-Yun;Jeong, Moon-Jin;Park, Young-Mee;Kwon, Byoung-Mog;Bae, Yun-Soo;Han, Mi-Young
    • BMB Reports
    • /
    • v.34 no.6
    • /
    • pp.537-543
    • /
    • 2001
  • In the present study, an in vitro ELISA system to assess the interaction between Src homology (SH)2 domains and phosphotyrosine that contain peptides was established using purified GST-conjugated SH2 proteins and synthetic biotinylated phosphotyrosine that contain oligopeptides. The SH2 domains bound the relevant phosphopeptides that were immobilized in the streptavidin-coated microtiter plate in a highly specific and dose-dependent manner. The epidermal growth factor receptor (EGFR)-, T antigen (T Ag)-, and platelet-derived growth factor receptor (PDGFR)-derived phosphopeptides interacted with the growth factor receptor binding protein (Grb)2/SH2, Lck/SH2, and phosphatidyl inositol 3-kinase (PI3K) p85/SH2, respectively. No cross-reactions were observed. Competitive inhibition experiments showed that a short phosphopeptide of only four amino acids was long enough to determine the binding specificity. Optimal concentrations of the GST-SH2 fusion protein and phosphopeptide in this new ELISA system for screening the binding blockers were chosen at 2nM and 500nM, respectively. When two candidate compounds were tested in our ELISA system, they specifically inhibited the Lck/SH2 and/or p85/SH2 binding to the relevant phosphopeptides. Our results indicate that this ELISA system could be used as an easy screening method for the discovery of specific binding blockers of protein-protein interactions via SH2 domains.

  • PDF

A Study on the Measurement of Anti-Cyclic Citrullinated Peptide (Anti-CCP) (Anti-Cyclic Citrullinated Peptide(Anti-CCP) 측정에 대한 연구)

  • Seo, Seol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.42-48
    • /
    • 2007
  • This study was carried out to review and evaluate anti-CCP ELISA assay for diagnostic in RA patients from an early arthritis clinic (EAC). The subjects were obtained from patients visiting the outpatient clinic of the Dept. of Rhumatology med.of P hospital in Daegu, during 6 months from July 1, 2006 to December 31, 2006. The subjects were 140 cases : 80 cases from RA patients (60 women and 20 men; mean age 58 years; range, 32-68 years) confirmed by clinical diagnostic. 39 cases of these RA patients were classified as having early RA (EAC). 50 cases (non-RA) did not fulfill the criteria for RA, and 10 cases were from healthy individuals. We performed the analysis with solid phase-ELISA method (ETI-max3000, Diasorin; Italy) for anti-CCP and Nephelometry assay (Roche/Hitachi 902 analyzer; USA) for RF. The results obtained were summarized as follows ; anti-CCP ELISA is more specific than RF Nephelometry assay (specificity 94% vs 90%) to diagnose RA patients with suspected EAC (early arthritis clinic). The combination test "anti-CCP and RF" had a very high specificity (specificity 98.3%, PPV; RA group 96%, EAC 95%), the difference was statistically significant (p<0.05). Anti-CCP ELISA had more sensitivity in EAC (Early arthritis clinic) patients than chronic RA patients (sensitivity 64% vs 24%, respectively), anti-CCP of RA group and EAC group was more specific than RF (anti-CCP PPV; 92%, 89% vs 89%, 81% respectively), the difference was statistically significant (p<0.05). The difference of antibody concetration between anti-CCP and RF for RA and the control group is statistically significant (p<0.05). In conclusion, anti-CCP ELISA testing may be useful if performed concomitantly with RF Nephelometry assay to diagnose RA patients with suspected EAC (early arthritis clinic).

  • PDF

Production of the Monoclonal Antibodies to the Escherichia coli Heat-Stable Enterotoxin (대장균의 내열성장독소 측정법개발을 위한 단세포군항체의 생산)

  • Chang, Woo-Hyun;Lee, Woo-Kon;Kim, Suck-Yong;Park, Jung-Bum
    • The Journal of the Korean Society for Microbiology
    • /
    • v.22 no.4
    • /
    • pp.377-392
    • /
    • 1987
  • Monoclonal antibody to the Escherichia coli heat-stable enterotoxin(ST) was produced to develop a rapid and convenient diagnostic method to the ST. The toxin was purified from culture supernatant of enterotoxigenic E. coli O148H28($ST^+/LT^+$) and conjugated to bovine serum albumin(BSA). The ST-BSA conjugate was used to immunize BALB/c mice and the immune spleen cells from these mice were fused with $P3{\times}63$ Ag8.V653 plasmacytoma cells. Hybridomas were screened by ELISA and positive hybridomas were cloned by limiting dilution. Finally, one stable clone (AS36) specific to ST was selected for further growth and characterization. Antibody titers of culture supernatant and ascitic fluid from BALB/c mice were 1:1,024 and 1:20,480 respectively in ELISA. The isotype and subclass of monoclonal antibody was IgG1 in sandwich ELISA. To test the neutralizing effect of monoclonal antibody on toxin activity of ST, mixture of ascitic fluid and ST was assayed by infant mouse assay and this monoclonel antibody was proved to be a neutralizing antibody. The titer of ascitic fluid which completely neutralized biological activity of 4 units of ST was 1:4. Purified ST was quantitatively measured by competitive ELISA and minimum amount of ST detectable by this assay was 250pg, which was an amount six-fold smaller than that detectable by infant mouse assay. Four reference strains of enterotoxigenic E. coli from WHO were detected by competitive ELISA and highly specific, sensitive and reproducible result was obtained.

  • PDF

Detection of a Thermal Stable-Soluble Protein (TSSP) as a Marker of Peanut Adulteration Using a Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay based on Monoclonal Antibodies

  • Sol-A Kim;Sazzad Hossen Toushik;Jeong-Eun Lee;Won-Bo Shim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.9
    • /
    • pp.1170-1178
    • /
    • 2023
  • Food allergy represents a severe problem for many societies, including sensitive populations, academies, health authorities, and the food industry. Peanut allergy occupies a special place in the food allergy spectrum. To prevent consumption by consumers suffering from a peanut allergy, a rapid and sensitive detection method is essential to identify unintended peanut adulteration in processed foods. In this study, we produced four monoclonal antibodies (MAbs; RO 3A1-12, PB 4C12-10, PB 5F9-23, and PB 6G4-30) specific to thermo-stable and soluble proteins (TSSPs) of peanut and developed an enzyme-linked immunosorbent assay (ELISA) based on the MAbs. Among them, PB 5F9-23 MAb was firmly bound to Ara h 1, and other MAbs strongly reacted to Ara h 3 in the Western blot analysis. An antibody cocktail solution of the MAbs was used to enhance the sensitivity of an indirect ELISA, and the limit of detection of the indirect ELISA based on the antibody cocktail solution was 1 ng/ml and improved compared to the indirect ELISA based on the single MAb (11 ng/ml). The cross-reaction analysis revealed the high specificity of developed MAbs to peanut TSSPs without cross-reaction to other food allergens, including nuts. Subsequently, analyzing processed foods by indirect ELISA, all foods labeled as containing peanuts in the product description were confirmed to be positive. The results indicate that the developed antibodies exhibit high specificity and sensitivity to peanuts and can be used as bio-receptors in immunoassays or biosensors to detect intentional or unintentional adulteration of peanuts in processed foods, particularly heat-processed foods.