• 제목/요약/키워드: ELF Magnetic Field

검색결과 63건 처리시간 0.026초

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

가전기기 발생 극저주파 자계 고조파 특성 해석 (Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances)

  • 민석원;송기현;양광호;주문노
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

Effect of a 60Hz electromagnetic field on the frequency of bleomycin-induced HPRT gene mutation and 1,2,4-benzenetriol-induced sister chromatid exchanges in CHO cell

  • Chung, Hai-Won;Kang, Su-Jin;Lee, Young-Joon;Kim, Su-Young
    • Journal of Radiation Protection and Research
    • /
    • 제27권2호
    • /
    • pp.81-87
    • /
    • 2002
  • The interaction of low density extremely low frequency magnetic field (ELF MF) in the frequency of hypoxanthine-guanine phosphoribosyltransferase (HPRT) mutation induced by bleomycin and on the frequency of sister chromatid exchanges (SCEs) induced by 1,2,4-benzenetriol(BT) was demonstrated. CHO cells pretreated with bleomycin or 1,2,4-benzenetriol were exposed for 24hrs to a sinusoidal 0.8mT magnetic field at 60Hz. Frequency of HPRT mutation and SCEs were determined. ELF MF exposure led to a two-fold increase of the frequency of HPRT mutation induced by bleomycin. No increase of mutation frequency was observed by ELF MF alone ELF MF also increased the frequency of SCEs induced by BT while no Increase of SCE frequencies were observed by ELF MF alone. These results suggest that low density ELF MF field would art as an enhancer rather than as an initiator of mutagenic effects in CHO cell.

ELF 전자계 특성 및 인체 안전기준에 관한 연구 (A Study on Characteristics and Safety Criteria for Human Body in ELF Electric and Magnetic Fields)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제8권3호
    • /
    • pp.34-43
    • /
    • 1993
  • This paper presents a study on the characteristics and safety criteria for human body in ELF (Extremely Low Frequency : 50-60Hz) electric and magnetic fields. Many researches for ELF electric and magnetic fields, which are developed in the past, are studied and analyzed In this paper. In order to estabilish the safety criteria for human body in the field, the field intensity, induced current and voltage are calculated by the electrostatic field approach which is far simpler than the electromagnetic field one based on Maxwell equation. The method is applied to the 345 KV transmission line system In operation and 765 KV system under consideration. According to the results, the maximum value of field intensity, 6.8627KV/m, is evaluated at the location which is 14m away from transmission line. As the safety criteria value by the abroad researches asserting that the human can detect the Induced current in 6KV/m and above, 5KV/m and 7KV/m are recommended at residence area and nonresidence area, respectively.

  • PDF

직업성 극저주파 자기장 노출평가와 노출 기준에 대한 쟁점 고찰 (Brief Review on Exposure Characteristics, Monitoring Instruments and Threshold Limit Values for Extremely Low Frequency-Magnetic Field (ELF-MF))

  • 박동욱;이승희;조경이
    • 한국산업보건학회지
    • /
    • 제32권4호
    • /
    • pp.381-392
    • /
    • 2022
  • Objectives: Objective of this study is to review briefly exposure characteristics, monitoring instruments and threshold limit values for extremely low frequency-magnetic field (ELF-MF) methods. This study was undertaken through brief literature review. We performed a literature search in PubMed to identify ELF-MF studies conducted in workplaces. Initial search keywords such as 'extremely low frequency-magnetic field (ELF-MF)' and 'electromagnetic fields (EMF)' combined or singly. We limited our review to occupational rather than general nonworkplace environmental exposures. Methods: The contents we reviewed: key industry and occupations generating ELF-MF, several direct-reading instruments monitoring ELF-MF and threshold limit values (TLV) preventing health effects may be caused by the exposure to ELF-MF. Results: The industries related to the generation and supply of electricity, electrolytic installations, welding, and induction heating and more were regarded as high ELF-MF exposure industries. All jobs handling or employed performed in power cable lines, electrical wiring, and electrical equipment are found to be exposed to ELF-MF. Threshold or ceiling limit, 1,000 µT, is established to prevent acute effects of exposure to low-frequency EMFs on the nervous system: the direct stimulation of nerve and muscle tissues and the induction of retinal phosphenes. The International Agency for Research on Cancer (IARC) has classified ELF-MF as possibly carcinogenic to humans chiefly based on epidemiological studies on childhood leukemia. However, a causal relationship between magnetic fields and several types of cancer including childhood leukemia has not been established nor has any other long-term effects. Risk management using precautionary measures, has been initiated by the US and EU to prevent chronic health effects related to ELF-MF exposure in workplaces. Conclusion: This study recommends the implementation of various measures such as theestablishment of occupational exposure limit values for ELF-MF and precautionary principle to prevent potential chronic occupational health effects may be caused by ELF-MF in Korea.

THE EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD (ELF-MF) ON THE FREQUENCY OF MICRONUCLEI IN HUMAN LYMPHOCYTES INDUCED BY BENZO(A)PYRENE

  • Cho, Yoon-Hee;Kim, Su-Young;Chung, Hai-Won
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2001년도 International Symposium on Dietary and Medicinal Antimutgens and Anticarcinogens
    • /
    • pp.178-178
    • /
    • 2001
  • The interaction of extremely low frequency magnetic field (ELF-MF) on the frequency of micronuclei (MN) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-MF of 0.8 mT field strength was applied for 24 hours either alone or with the tumour initiator, BP. The frequency of MN induced by BP increased in a dose-dependent manner.(omitted)

  • PDF

가전기기에서 발생되는 극저주파 과도자계 예측기법 연구 (Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances)

  • 주문노;양광호;명성호;민석원
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

극저주파 디지털 자계 측정기의 설계 및 구현 (Design and Implementation of ELF Digital Magnetic Fields Meter)

  • 임재유;황정환;김원호
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.84-88
    • /
    • 2015
  • 본 논문은 극저주파 자계 세기를 무선 모니터링하기 위한 디지털 자계측정기의 설계 및 구현에 대해 기술한다. 우리 실생활에 극 저주파대역의 자기장이 노출되어 있어 인체에 자기장이 얼마나 영향을 미치는가에 대한 연구의 필요성이 있으며 그에 따른 측정 장비의 수요가 증가하고 있다. 본 논문에서는 3-축 코일형 자계센서를 사용하였으며, 자계의 측정 범위는 0.03~10uT, 주파수 범위는 40~180Hz이다. 자계 세기의 측정과 주파수 특성을 보상하는 등화기능은 DSP 기반의 디지털 방식으로 설계하였으며, 측정 값은 와이파이 통신을 이용하여 PC 모니터링 할 수 있도록 설계 및 구현하였고 측정오차는 6% 이내로 실용성을 확인하였다.

계통상태를 고려한 송전선의 ELF 전자계 (ELF Electric and Magnetic Fields under the Transmission Line Including Electric Power System States)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.89-96
    • /
    • 1996
  • This paper presents a study on the analysis and evaluation for ELF( Extremely Low Frequency) electric and magnetic fields under the transmission line according to the power system states. The power system states are classified into two types, normal state resulting from normal operation and alert state from outages. The current in a system is changed continually owing to the load fluctuations even in a normal operation. To calculate the current of the concerned line in a normal state, the system load level is devided into light, base and heavy load level. In case of contingency, an efficient algorithm based on matrix inversion lemma is developed to figure out the current changes. In order to analyze the variations of ELF field caused by the current fluctuations the electrostatic field approach which is far simpler than the electromagnetic field one based on Maxwell equation is introduced in this paper. The suggested method is applied to the IEEE 14 bus system to demonstrate the usefulness.

  • PDF

송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석 (Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line)

  • 명성호;조연규;이동일;임윤석
    • 한국전자파학회논문지
    • /
    • 제17권11호
    • /
    • pp.1132-1142
    • /
    • 2006
  • 본 연구는 송전 선로 여러 가지 유형의 극저주파 자기장 저감 적용 모델을 조사하고 그 효과를 분석하였다. 본 연구에서는 154 kV 수평 배열 송전 선로를 기본으로 하여 적용 가능한 다양한 자기장 저감 모델에 대하여 적용시 얻게 되는 자기장 저감지수(Field Reduction Factor)를 검토하였다. 그 결과 compact 모델 채용시에는 상간거리 compact화 비율과 자기장 저감지수가 거의 비례하였으며, diamond 모델 및 transposed 선로 배치의 경우는 50 %에 근접한 자기장 저감이 가능하였다. 배전 선로에 적용이 가능한 삼각형 배열은 33 % 정도, 2회선 split는 50 % 정도 저감 효과가 나타나는 것으로 분석되었으며 수평 multi split 모델의 경우는 80 %까지 자기장 저감을 얻을 수 있었다.