• 제목/요약/키워드: ELF (extremely low frequency)

검색결과 73건 처리시간 0.025초

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

Effects on G2/M Phase Cell Cycle Distribution and Aneuploidy Formation of Exposure to a 60 Hz Electromagnetic Field in Combination with Ionizing Radiation or Hydrogen Peroxide in L132 Nontumorigenic Human Lung Epithelial Cells

  • Jin, Hee;Yoon, Hye Eun;Lee, Jae-Seon;Kim, Jae-Kyung;Myung, Sung Ho;Lee, Yun-Sil
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권2호
    • /
    • pp.119-124
    • /
    • 2015
  • The aim of the present study was to assess whether exposure to the combination of an extremely low frequency magnetic field (ELF-MF; 60 Hz, 1 mT or 2 mT) with a stress factor, such as ionizing radiation (IR) or $H_2O_2$, results in genomic instability in non-tumorigenic human lung epithelial L132 cells. To this end, the percentages of G2/M-arrested cells and aneuploid cells were examined. Exposure to 0.5 Gy IR or 0.05 mM $H_2O_2$ for 9 h resulted in the highest levels of aneuploidy; however, no cells were observed in the subG1 phase, which indicated the absence of apoptotic cell death. Exposure to an ELF-MF alone (1 mT or 2 mT) did not affect the percentages of G2/M-arrested cells, aneuploid cells, or the populations of cells in the subG1 phase. Moreover, when cells were exposed to a 1 mT or 2 mT ELF-MF in combination with IR (0.5 Gy) or $H_2O_2$ (0.05 mM), the ELF-MF did not further increase the percentages of G2/M-arrested cells or aneuploid cells. These results suggest that ELF-MFs alone do not induce either G2/M arrest or aneuploidy, even when administered in combination with different stressors.

컴퓨터 모니터 발생 전자파 차단에 미치는 선인장의 효과 유무 (Effects of Cacti on the Protection against Low Frequency Electromagnetic Waves Radiated from Computer Monitor)

  • 손기철;류명화;박웅규
    • 원예과학기술지
    • /
    • 제17권6호
    • /
    • pp.773-776
    • /
    • 1999
  • 선인장 및 몇 가지 식물이 컴퓨터 모니터로 부터 발생되는 ELF 및 VLF 전자파의 차단효과에 미치는 영향이 조사되었다. 모니터의 정면에서 전자파가 가장 많이 방출되었으며, 차단효과의 검증을 위해 식물과 다른 대상물들은 모니터의 정면 혹은 측면에 두었다. 측정된 모든 식물에서 모니터 발생의 전자파 중 자계 (magnetic waves) 차단에는 전혀 효과적이지 못한 것으로 나타났다. 한편, 선인장의 크기, 형태, 그리고 배치방법에 따라서는 약간의 전계(electric waves) 차단효과가 있는 것으로 나타났으나, 경미하여 TCO의 규정치(electric field: 10V/m and 1V/m in ELF and VLF, respectively)에는 미치지 못하기 때문에 실용화하기에는 어려운 것으로 판단된다.

  • PDF

고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구 (Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines)

  • 박성애;정준식;최태봉;정민주;김부경;이종천
    • 환경영향평가
    • /
    • 제27권6호
    • /
    • pp.658-673
    • /
    • 2018
  • 극저주파자기장 노출에 대한 사회적 갈등은 계속되는 전력 수요의 증가와 고압송전선로의 증설로 심화될 것으로 예상되고 있다. 그러나 현행 환경영향평가법상 이에 대한 구체적 작성규정이나 지침이 마련되어 있지 않은 실정이다. 따라서 본 연구는 극저주파자기장의 주요 발생원이라 할 수 있는 고압 가공 송전선로를 대상으로 환경영향평가 사례분석, 현장측정 및 전문가 자문을 통하여 환경영향평가 방법에 대한 표준화 연구를 수행하였다. 극저주파자기장의 환경영향평가의 문제점과 개선해야 할 사항을 도출하고, 이를 반영하여 환경영향평가 방법을 제안하였다. 주요내용으로는 환경영향평가의 현황조사-영향예측-저감방안마련-사후환경영향평가계획의 각 단계에서 거리와 전류량에 영향을 받는 극저주파자기장의 물리적 특성을 고려한 계획수립 및 결과분석 과정을 제안하였다. 본 연구 내용을 기반으로 환경영향평가 실무에 적용시킬 수 있는 '전력선에 대한 극저주파자기장 공정시험방법(안)'과 '전력선에서의 극저주파자기장 측정기록표'를 마련하였고, 29개 항목의 극저주파자기장 점검표를 작성하였다. 이러한 연구결과는 극저주파자기장의 장기적 노출에 대한 인체유해성이 불명확한 현 시점에서 송전선로 피해와 갈등을 최소화하고 합리적 방안을 도출하는 환경영향평가에 활용될 수 있을 것이다.

Biological Effects of Static Magnetic Fields and ELF-Electromagnetic Field on Microcirculation in Animals

  • Ohkubo, Chiyoji;Okano, Hidyuki;Xu, Shenzhi;Gmitrov, Jraj
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 1999년도 제3회 전자장의 생체영향에 관한 워크숍
    • /
    • pp.117-129
    • /
    • 1999
  • Acute effects of locally applied of static magnetic field (SMF) and extremely low frequency electromagnetic field(ELF-EMF) to the cutaneous tissue within a rabbit ear chamber (REC)were evaluated under conscious conditions. Rabbits with the REC were subjected to intravital microscopical investigation by use of microphotoelectric plethysmography(MPPG). There was no dose-response relationship between the extent of vasomotion changes and frequencies(0,20,50, 100Hz)or power levels (1, 5, 10, 25, 50, 100, 200 mT). Under low vascular tone the both fields induce vasodilatation. The effects of SMF (1 mT) on the cutaneous microcirculatory system induced the vasodilatation with enhanced vasomotion under nor-adrenaline-induced high vascular tone as well as the vasoconstriction with reduced vasomotion under acetylcholine-induced low vascular tone. This suggests that the SMF can modulate vascular tone due to the modification of vasomotion biphasically in the cutaneous tissue.

  • PDF

극저주파 디지털 자계 측정기의 설계 및 구현 (Design and Implementation of ELF Digital Magnetic Fields Meter)

  • 임재유;황정환;김원호
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.84-88
    • /
    • 2015
  • 본 논문은 극저주파 자계 세기를 무선 모니터링하기 위한 디지털 자계측정기의 설계 및 구현에 대해 기술한다. 우리 실생활에 극 저주파대역의 자기장이 노출되어 있어 인체에 자기장이 얼마나 영향을 미치는가에 대한 연구의 필요성이 있으며 그에 따른 측정 장비의 수요가 증가하고 있다. 본 논문에서는 3-축 코일형 자계센서를 사용하였으며, 자계의 측정 범위는 0.03~10uT, 주파수 범위는 40~180Hz이다. 자계 세기의 측정과 주파수 특성을 보상하는 등화기능은 DSP 기반의 디지털 방식으로 설계하였으며, 측정 값은 와이파이 통신을 이용하여 PC 모니터링 할 수 있도록 설계 및 구현하였고 측정오차는 6% 이내로 실용성을 확인하였다.

가전기기 발생 극저주파 자계 고조파 특성 해석 (Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances)

  • 민석원;송기현;양광호;주문노
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

극저주파 자계 세기를 원격 측정하는 장치 (Telemetering System of Extremely Low Frequency Magnetic Field Intensity)

  • 유호상;왕종욱;서근미;김윤명
    • 한국전자파학회논문지
    • /
    • 제18권5호
    • /
    • pp.553-562
    • /
    • 2007
  • 본 논문에서는 극저주파 자계 세기를 원격으로 측정하기 위한 장치를 설계하고 제작하였다. 자계 측정기는 자계를 등방적으로 측정하기 위하여 3축 자계 센서를 사용하였으며, 측정 대역내 주파수에서 주파수 특성을 보상하기 위하여 등화기를 사용하였다. 3축 자계 센서의 출력 신호를 시간적으로 다중화 시켜, 3축간 균일한 이득 및 주파수 특성을 얻었다. 자계 측정 레벨 범위는 $0.01{\sim}10.0\;uT$이며, 측정 주파수 대역은 $40{\sim}180\;Hz$이 되도록 설계하였다. 제어 시스템은 무선으로 자계 측정기에 접근하며, 최대 접근 거리는 1.0 km이다. 제작된 장치의 측정 레벨 오차는 5% 이내이다. 제작된 장치는 고전압 송전선이 지나는 골프 연습장에 설치되었다.

지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가 (Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation)

  • 이지현;강명지;박윤경;박동욱;최상준
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.