• Title/Summary/Keyword: EDs

Search Result 2,031, Processing Time 0.027 seconds

MIC with Ripple Voltage Compensator Using Regenerative Snubber (에너지 회생형 스너브를 이용한 리플 전압 억제기를 가지는 MIC(Module Integrated Converter))

  • Kim, Hong-Sung;Chang, Hun Ki;Yoon, Yeo Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.75-76
    • /
    • 2014
  • This study deals with a isolation type MIC(Module Integrated Converter) for AC module with advantages such as DC Wireless, freely selectable installation capacity, minimized shadow effect etc. In this paper, MIC circuit with the function which can remove the ripple voltage of PV module and give the discharging path for charged energy in leakage inductance of isolation transformer. The validity of proposed circuir is verified by the simulation with PSIM.

  • PDF

Knowledge Management in LG-EDS Systems: A Tool for Innovation

  • Jiwon Han;Park, Dong-Hyun
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2001.01a
    • /
    • pp.393-399
    • /
    • 2001
  • The Purpose of this paper is how KM is implemented and executed to reform the organization in the change management aspect and how its current KM can be developed in the future, mainly based on the organizational system, business process, and information system related to KM. This Paper is longitudinal case study of Knowledge Management at LG-EDS Systems. The effective approach to undertake KM is phase. First, it is structured to share explicit knowledge for better performance and then implicit knowledge for best performance. But, This method had some limitations. So, LG-EDS systems integrated KMS-Knowledge Portal-to facilitate cooperation and improve contents quality.

  • PDF

Spontaneous Carotid-Cavernous Fistula in the Type IV Ehlers-Danlos Syndrome

  • Kim, Jeong Gyun;Cho, Won-Sang;Kang, Hyun-Seung;Kim, Jeong Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.92-95
    • /
    • 2014
  • Ehlers-Danlos syndrome (EDS) is a rare inherited connective disease. Among several subgroups, type IV EDS is frequently associated with spontaneous catastrophic bleeding from a vascular fragility. We report on a case of carotid-cavernous fistula (CCF) in a patient with type IV EDS. A 46-year-old female presented with an ophthalmoplegia and chemosis in the right eye. Subsequently, seizure and cerebral infarction with micro-bleeds occurred. CCF was completely occluded with transvenous coil embolization without complications. Thereafter, the patient was completely recovered. Transvenous coil embolization can be a good treatment of choice for spontaneous CCF with type IV EDS. However, every caution should be kept during invasive procedure.

Status of Advanced Tecnhologies and Domestic Researches for Development of Korean Next Generation Maglev (한국형 차세대 자기부상열차 개발을 위한 선진기술분석 및 국내연구현황)

  • Cho, Han-Wook;Bang, Je-Sung;Han, Hyung-Seok;Sung, Ho-Kyung;Kim, Dong-Sung;Kim, Byung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1767-1776
    • /
    • 2008
  • This paper presents the status of advanced technologies and domestic researches for development of Korean next generation maglev. Generally, two specific configurations such as the EMS (Electromagnetic Suspension) with LSM (Linear Synchronous Motor) and EDS (Electrodynamic Suspension) with LSM can be employed as a propulsion and levitation device of high-speed maglev. Worldwide high-speed maglev developments refer to projects such as the German Transrapid with EMS, the Japanese MLX with EDS, and the U.S. Inductrack with PM (Permanent Magnet) EDS maglev system. In this paper, the propulsion and levitation systems of these world wide high-speed maglev have been reviewed and analysed.

Development of an Extended EDS(Earliest Deadline Scheduling) Algorithm for the CAN-Based Real-Time System (CAN기반 실시간 시스템을 위한 확장된 EDS 알고리즘 개발)

  • Lee, Byong-Hoon;Kim, Hong-Ryeol;Kim , Dae-Won
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.294-301
    • /
    • 2002
  • A new dynamic scheduling algorithm is proposed for CAN-based real-time system in this paper. The proposed algorithm is extended from an existing EDS(Earliest Deadline Scheduling) approach having a solution to the priority inversion. Using the proposed algorithm, the available bandwidth of network media can be checked dynamically, and consequently arbitration delay causing the miss of deadline can be avoided. Also, non-real time messages can be processed with their bandwidth allocation. Full network utilization and real-time transmission feasibility can be achieved through the algorithm. To evaluate the performance of algorithm, two simulation tests are performed. The first one is transmission data measurement per minute for periodic messages and the second one is feasibility in the system with both periodic messages and non-real time message.

A Study about Optimization of Laser_repair Condition in EDS Area to Improve the Speed Parameter of High Speed DRAM (High Speed DRAM의 Speed 특성 향상을 위한 EDS Laser_Repair Condition 최적화 방안 연구)

  • Kim, Li-Soon;Han, Young-Shin;Lee, Chil-Gee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.1-6
    • /
    • 2002
  • This study is about optimization of Laser Repair Condition in EDS Line to improve AC and DC characteristic of high speed DRAM. The margin of AC parameter can be improved by forcing the proper DC generator levels and also improved by cutting the optional fuse about characteristics.

The analysis of field condition for partial discharge using portable GIS diagnosis system (휴대용 GIS 진단장치를 이용한 부분방전 현장조사결과 분석)

  • Jeong, Jae-Ki;Yoon, Si-Young;Kang, Chang-Ik;Jin, Young-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.128-130
    • /
    • 2007
  • GIS를 포함한 전력기기의 신뢰도를 높이기 위해서는 절연체 내부에서 부분방전이 발생하는 것을 최소한으로 억제할 필요가 있다. GIS 내부에서 발생하는 부분방전은 사전에 진단하여 예방을 하는 것이 중요하며 이를 방치할 경우 대형사고로 이어질 확률이 매우 크다. 현재까지는 대부분의 GIS 진단장비가 외국제품이라 국내실정에 맞지 않고 가격이 비싸며 고장 시 유지보수가 힘들다는 단점을 가지고 있다. 이러한 단점을 극복하기 위해서 본 연구내용에서는 손쉽게 부분방전을 판단할 수 있도록 저가형, 휴대형으로 개발한 GIS 진단장비에 대해 설명하고 GIS 현장에 실제 적용하여 실측한 부분방전에 대한 자료와 변전소의 부분방전 발생형태를 조사하는데 역점을 두었다.

  • PDF

Transmission Monitoring System Development Based on Mobile and Web Environment (송전선 운용 중심의 송전선 감시 시스템)

  • Jeong, Jae-Ki;Choi, Yun-Jong;Shin, Dong-Hyuk;Lee, Seung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.110-113
    • /
    • 2007
  • 전력 공급을 위한 송전 설비는 낙뢰 및 온도변화에 직접적인 영향을 받고 있으며, 이런 환경적 영향에 의해 안정적인 전력 공급이 어려운 실정이다. 환경 변화에 따른 송전선의 합리적인 운용과 안정성이 부각되면서 송전 설비를 관리하는 시스템의 도입이 필요한 실정이지만, 막대한 건설비용과 운용시 발생하는 전자파 문제 등으로 인해 쉽게 적용하지 못하고 있는 실정이다. 이러한 문제점을 해결하기 위해서는 관리적인 측면과 경제적인 측면을 고려하여 환경 변화에 따른 송전선의 이상 변화를 감시하고 관리 할 수 있는 시스템의 도입이 필요하며, 본 연구에서는 이런 문제점을 개선하는데 역점을 두었다.

  • PDF

Lightning Arrester On Power Diagnosis of Distribution System and Field Application (배전계통의 활선상태 피뢰기 진단 및 현상적용)

  • Lee, Man-Kyu;Ryu, Hyuk;Choi, Yun-Chong;Jung, Jae-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.192-197
    • /
    • 2004
  • 전국적인 분포를 갖고 있는 배전망에 유일한 과전압 보호 및 절연보호장치인 피뢰기는 배전계통에서의 사고율을 감소시키는 중요한 역할을 수행한다. 이러한 피뢰기의 수명은 동작횟수의 증가에 의해서 서서히 열화되게 된다. 이러한 열화의 과정은 피뢰기의 저항성 전류가 증가하는 현상과 일치한다. 그러나 배전계통에서 저항성 전류를 검출하기 위한 전압요소에 대한 정보를 얻기가 쉽지않다. 본 논문에서는 이러한 피뢰기의 열화현상을 파악하기 위하여 이론적으로 피뢰기의 열화정도가 고조파의 분석만으로 가능하다는 점을 증명하고 특히 3고조파의 증가와 저항성 전류의 증가가 비례함을 현장에서 수집한 피뢰기의 실증을 통해 입증하였다. 이러한 연구결과를 현장에 적용하여 현장의 가혹한 조건의 전자계영향에도 불구하고 정밀한 피뢰기 진단이 가능하다는 결론에 도달하였다. 결론적으로 본 연구의 결과로 현장의 피뢰기 진단이 간편해지고 효율적으로 이루어 질 수 있음을 실증하였고, 앞으로 배전계통에서의 안정적인 전력공급에 기여할 것으로 기대하고 있다.

  • PDF

Fault Diagnosis of M.tr using Acoustic Sensor Technique (초음파 기술을 이용한 변압기 이상상태 진단)

  • Jeong, Jae-Ki;Yoon, Si-Young;Kang, Chang-Ik;Jin, Young-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.744-745
    • /
    • 2007
  • 변압기를 진단하는 분석 요소 중 흔히 사용하는 방법으로 유중가스분석을 이용하는 방식을 많이 사용하고 있다. 유중가스 분석은 변압기 내 Oil이 열과 Arc등에 의해 화학적으로 변화된 것을 측정하여 열화 정도를 추정하는 방식이지만 신속한 검출 및 위치추정이 불가능하다는 단점이 있다. 신속한 검출이 되지 않으면 신속한 보고가 이루어 질 수 없으므로 변압기 교체시점을 맞추지 못하여 사고로 인한 막대한 피해보상이 발생한다. 이런 단점을 보완하기 위해 변압기내 부분방전 및 Arc에 의해 발생하는 부분방전신호를 초음파 대역에서 검출하여 열화 및 위치를 추정할 수 있는 초음파 분석이 필요하게 되었고 실험을 통해 변압기에 대한 분석, 진단을 시행하였다.

  • PDF