• Title/Summary/Keyword: ECHO 7

Search Result 283, Processing Time 0.029 seconds

Modification of Polar Echo Kernel for Performance Improvement of Audio Watermarking

  • Kim, Siho;Hongseok Kwon;Keunsung Bae
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.7-10
    • /
    • 2003
  • In this paper, we present a new echo kernel, which is a modification of polar echo kernel. to improve the detection performance and robustness against attacks. Polar echo kernel may take advantage of large detection margin from the polarity of inserted echo signal, but its poor frequency response in low frequency band degrades sound quality. To solve this problem, we applied bipolar echo pulses to the polar echo kernel. Using the proposed echo kernel the distributions of autocepstrum peaks fur data ‘0’ and ‘1’ are located more distant and improvement of detection performance is achieved. It also makes the low frequency band flat so that the timbre difference in the polar echo kernel can be removed to reproduce the imperceptible sound qualify. Informal listening tests as well as robustness test against attacks were performed to evaluate the proposed echo kernel. Experimental results demonstrated the superiority of the proposed echo kernel to both conventional unipolar and polar echo kernels

  • PDF

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Radiologic Findings of Uncommon Breast Cancer (드문(Uncommon) 유방암의 방사선학적 소견)

  • Kim, Jae-Woon;An, Jae-Hong;Hwang, Mi-Soo;Lee, Jae-Kyo;Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.114-124
    • /
    • 1998
  • We analyzed the mammographic (n=21) findings (location, margin, shape, cluster microcalcifications, size, multiplicity) and ultrasonographic (n=12) findings (shape, border, internal echo, boundary echo, posterior echo, lateral echo, width/depth ratio) to evaluate specific radiologic findings of histopathologically proved uncommon breast cancer. The mammographic findings (n=21) are as follow; 1) single; 16, multiple; 5 2) margin (smooth; 13, irregular; 4, spiculated; 4) 3) shape (round and ovoid; 9, lobulated; 8, irregular; 4) 4) cluster micro calcifications (abscent; 20, present; 1) 5) size (1-3cm; 18, 3-5cm; 2, 5cm> ; 1) 6) location (UOQ; 13, UIQ; 4, LIQ; 3, LOQ; 1). The ultrasonographic findings (n=12) are as follow; 1) shape (round to oval; 5, lobulated; 5, irregular; 2) 2) border (smooth even; 9, rough uneven; 3) 3) internal echo (fine homogeneous; 5, coarse heterogeneous; 7) 4) boundary echo (regular fine; 4, irregular thick; 8) 5) posterior echo (enhanced; 11, no change; 1) 6) lateral echo (marked; 7, nonexistent; 5) 7) width/depth ratio (1.5> ; 1, 1.0-1.5; 7, 1.0< ; 4). Uncommon breast cancer show benign nature on mammogram, but malignant nature on ultrasonogram (especially boundary echo, internal echo, width/depth ratio).

  • PDF

Inspection for Internal Flaw and Thickness of Concrete Tunnel Lining Using Impact Echo Test (충격반향시험에 의한 콘크리트 터널 라이닝 내부결함 및 두께 조사)

  • 김영근;이용호;정한중
    • Tunnel and Underground Space
    • /
    • v.7 no.3
    • /
    • pp.230-237
    • /
    • 1997
  • As concrete structure is getting old and decrepit, its inspection and diagnosis is getting important. Therefore, it is necessary to estimate the soundness of structure using non-destructive tests for effective repairs and maintenances. But, applications of non-destructive tests in tunnel have been used restrictively, due to accessibility only from one side in tunnel lining and presence of tunnel installations. Recently, the various non-destructive techniques have been studied. Especially, ground penetrating radar(GPR) and impact echo (IE) methods have been researched for tunnel inspection. In this study, the applicability of impact echo test in tunnel lining inspection has been investigated. This paper described the tunnel inspection for lining thickness and internal flaw using impact echo tests. Model tests were carried out using impact echo test systems on two concrete models, Model I is measuring for lining thickness, Model II is detecting for internal flaw. Also, the test were applied for lining inspections in a tunnel constructed by NATM. From the results of impact echo tests, we have concluded that impact echo test is a very useful and effective technique for inspecting the concrete tunnel linings.

  • PDF

Late Quaternary Sedimentation in the Yellow Sea off Baegryeong Island, Korea (한국 황해 백령도 주변해역 후 제4기 퇴적작용)

  • Cho, MinHee;Lee, Eunil;You, HakYoel;Kang, Nyen-Gun;Yoo, Dong-Geun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.145-153
    • /
    • 2013
  • High-resolution chirp profiles were analyzed to investigate the echo types of near-surface sediments in the Yellow Sea off the Baegryeong Island. On the basis of seafloor morphology and subbottom echo characters, 7 echo types were identified. Flat seafloor with no internal reflectors or moderately to well-developed subbottom reflectors (echo type 1-1 and 1-2) is mainly distributed in the southern part of the study area. Flat seafloor with superposed wavy bedforms (echo type 1-3) is also distributed in the middle part. Mounded seafloor with either smooth surface or superposed bedforms (echo type 2-1, 2-2, and 2-3) occurs in the middle part of the study area. Irregular and eroded seafloor with no subbottom reflectors (echo type 3-1) is present in the northern part of the study area off the Baegryeong Island. According to the distribution pattern and sedimentary facies of echo types, depositional environments can be divided into three distinctive areas: (1) active erosional zone due to strong tidal currents in the northern part; (2) formation of tidal sand ridges in response to tidal currents associated with sea-level rise distributed in the middle part; and (3) transgressive sand sheets in the southern part. Such a depositional pattern, including 7 echo types, in this area reflects depositional process related to the sea-level rise and strong tidal currents during the Holocene transgression.

A Study on the Working Poor among Korean Echo Boomers (에코부머의 근로빈곤에 관한 연구)

  • Park, Mee Sok;Park, Mee Ryeo
    • Human Ecology Research
    • /
    • v.52 no.1
    • /
    • pp.87-101
    • /
    • 2014
  • The purpose of this study is to identify the current status of the working poor and the factors that are influential to the working poor among echo boomers. This study is a secondary analysis using the data from the 7th analysis of the 2012 Korea Welfare Panel Survey, conducted by Korea Institute for Health and Social Affairs. This analysis considered Korean echo boomers born between 1979 and 1985. In our final analysis, we used 1,226 echo boomers who had the ability to work. For the analysis, the SAS/PC statistical program ver. 9.3 was utilized. The research findings are as follows; Firstly, of the working poor among the echo boomers, only 22% were in the state of poverty. Secondly, more echo boomers living in a metropolitan city, city, gun/urban-rural area and district than those in the Seoul were categorized as among the working poor; the same was true for those who lived in a free house than in a leased room or a room that was rented by the month. Thirdly, more echo boomers whose education level was high school graduate or less rather than college graduate or less or university graduate or more were categorized as among the working poor; this was also true for echo boomers whose employment type was temporary employment, self-employment, or unemployment rather than a full-time job.

Studies on Estimation of Fish Abundance Using an Echo Sounder ( 1 ) - Experimental Verification of the Theory for Estimating Fish Density- (어군탐지기에 의한 어군량 추정에 관한 기초적 연구 ( 1 ) - 어군량추정이론의 검증실험 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • An experiment has been carefully designed and performed to verify the theory for the echointergration technique of estimating the density of fish school by the use of steel spheres in a laboratory tank. The spheres used to simulate a fish school were randomly distributed throughout the insonified volume to produce the acoustic echoes similar to those scattered from real fish schools. The backscattered echoes were measured as a function of target density at tow frequencies of 50kHz and 200kHz. Data acquisition, processing and analysis were performed by means of the microcomputer-based sonar-echo processor including a FFT analyzer. Acoustic scattering characteristics of a 36cm mackerel was investigated by measuring fish echoes with frequencies ranging from 47.8kHz to 52.0kHz. The fluctuation of bottom echoes caused by the effects of fish-school attenuation and multiple scattering which occurred in dense aggregations of fishes was also examined by analyzing the echograms of sardine schools obtained by a 50kHz telesounder in the set-net's bagnet, and the echograms obtained by a scientific echo sounder of 50kHz in the East China Sea, respectively. The results obtained can be summarized as follows: 1. The measured and the calculated echo shapes on the steel sphere used to simulate a fish school were in close agreement. 2. The waveform and amplitude of echo signals by a mackerel without swimbladder fluctuated irregularly with the measuring frequency. 3. When a collection of 30 targets/m super(3) lied the shadow region behind another collection of 5 targets/m super(3), the mean losses in echo energy for the 30 targets/m super(3) were about -0.4dB at 50kHz and about -0.2dB at 200kHz, respectively. 4. In the echograms obtained in the East China Sea, the bottom echoes fluctuated remarkably when the dense aggregations of fish appeared between transducer and seabed. Especially, in the case of the echograms of sardine school obtained in a set-net's bagnet, the disappearance of bottom echoes and the lengthening of the echo trace by fish aggregations were observed. Then the mean density of the sardine school was estimated as 36 fish/m super(3). It suggests that when the distribution density of fishes in oceans is greater than this density, the effects of fish-school attenuation and multiple scattering must be taken into account as a possible source of error in fish abundance estimates. 5. The relationship between mean backscattering strength (, dB) and target density ($\rho$, No./m super(3)) were expressed by the equations: =-46.2+13.7 Log($\rho$) at 50kHz and =-43.9+13.4 Log($\rho$) at 200kHz. 6. The difference between the experimentally derived number and the actual number of targets gradually decreased with an increase in the target density and was within 20% when the density was 30 targets/m super(3). From these results, we concluded that when the number of targets in the insonified volume is large, the validity of the echo-integration technique of estimating the density of fish schools could be expected.

  • PDF

General Primer-Mediated PCR Detection of Enteroviruses Causing Aseptic Meningitis (General Primer를 이용한 무균성뇌막염 원인 바이러스 분석)

  • Kim, M.B.;Kim, K.S.;Bae, Y.B.;Song, C.Y.;Yoon, J.D.;Lee, K.H.;Shin, H.K.
    • The Journal of Korean Society of Virology
    • /
    • v.26 no.2
    • /
    • pp.215-225
    • /
    • 1996
  • Aseptic meningits, an acute inflammation of the meninges, is a common illness during childhood. Virus is the most important cause of aseptic meningitis. Especially enterovirus causes approximately above 85% of all cases of aseptic meningitis. In 1993, there was a big epidemic of aseptic meningitis by ECHO 9 and ECHO 30 viruses. And ECHO 3 virus was isolated as a causative agent of aseptic meningitis in 1994. This study was aimed to detect the causative agent of aseptic meningitis in 1995 and to analyze the 5'-noncoding region which was used to detect virus. Virus was isolated from 87 stools and cerebrospinal fluid specimens of the patients by cultured RD and HEp-2 cell. Neutralizing antibody tests using enterovirus serum pool were performed on the specimens with cytopathic effect. 3 of ECHO 7 viruses and 5 of Coxsackie B3 viruses were isolated from stool specimens and 1 of ECHO 7 and Coxsackie B3 mixed type was confirmed from cerebrospinal fluid specimens. RNA was isolated from the culture supernatants of infected cells and general primers were selected in highly conserved part of the 5'-noncoding region of the enteroviral genome for RT-PCR. PCR product from this virus showed a 152bp band on gel electrophoresis. Sequence of obtained DNA was compared with prototype sequences by accessing to the Genebank database. 5'-noncoding region of isolated Coxsackie B3 virus, which has point mutations in nucleotide sequence positions 493, 497, 502, 523, was closely related to that of polio virus type 1, Mahoney strain. In case of isolated ECHO 7 virus, nucleotide has been changed from cytosine to thymine at position 581 and from thymine to cytosine at position 583. We concluded the causative agents of the outbreak of aseptic meningitis during June to July in 1995 were both ECHO 7 and Coxsackie B3 virus, and the primer used in this study could allow a rapid diagnosis of enteroviruses by PCR.

  • PDF

A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study (3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The information of contrast media concentration on target organ is very important to get reduce the side effect and high contrast imaging. We investigated alternation of signal intensity as a function of the modality of Gd-based contrast media on spin echo and ultra short time echo (UTE) of T1 effective pulse sequence at 3T MRI unit. Gadoxetic acid, which is a MRI T1 contrast medium, was used to manufacture an agarose phantom diluted in various molarities, and sterile water and agarose 2% were used as the buffer solution for the dilution. The gold standard T1 calculation was based on coronal single section imaging of the phantom mid-point with 2D Inversion recovery spine-echo pulse sequence MR imaging for testing of phantom accuracy. The 1-2mmol/L and 7mmol/L was shown the maximum signal intensity on spin echo and UTE respectively. We confirm the difference of contrast media concentration which was shown the maximum signal intensity depending on the T1 effective pulse sequence.

T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence

  • E-K. Jeong;Lee, S-H.;J-S. Suh;Y-Y wak;S-A. Shin;Y-K. Kwon;Y. Huh
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.7-20
    • /
    • 1997
  • The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map.

  • PDF