• 제목/요약/키워드: ECG-Sensing Clothing

검색결과 10건 처리시간 0.025초

섬유전극을 기반으로 한 라이프스타일 모니터링용 ECG-센싱의류의 프로토타입 연구 (A Study on a Prototype of ECG-Sensing ClothingBased on Textile Electrode for Lifestyle Monitoring)

  • 강다혜;조하경;송하영;조현승;이주현;이강휘;구수민;이영재;이정환
    • 감성과학
    • /
    • 제11권3호
    • /
    • pp.419-426
    • /
    • 2008
  • In order to develop "textile electrode - sensing clothing" which is a sort of smart clothing to measure electric activities of heart, we propose possible ways to develop textile electrode and design of sensing clothing, ultimately aiming to develop "ECG sensing clothing for lifestyle monitoring". Conventional sensors for measuring typical electric activities of heart keep certain distance between measuring electrodes to measure signals for electric activities of heart, but these sensors often cause inappropriate factors (e.g. motional artifacts, inconvenience of use, etc) for monitoring natural cardiac activities in our daily life. In addition, most of textile electrodes have made it difficult to collect data due to high impedance and unstable contact between skin and electrodes. To overcome these questions, we minimized distance between electrodes and skin to maximize convenience of use. And in order to complement contact between skin electrodes, we modified textile electrode's form and developed ways to design clothing. As a result, we could find out clinical significance by investigating possible associations of clinical electrocardiogram (ECG) with variation of distance between electrodes, and could also demonstrate clinically significant associations between textile electrode developed herein and clothing.

  • PDF

체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구 (A Study of Sensing Locations for ECG Monitoring Clothing based on the Skin Change rate)

  • 조하경;조상우
    • 한국의류산업학회지
    • /
    • 제17권5호
    • /
    • pp.844-853
    • /
    • 2015
  • Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20' with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로- (A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing-)

  • 조하경;송하영;조현승;구수민;이주현
    • 감성과학
    • /
    • 제13권3호
    • /
    • pp.467-474
    • /
    • 2010
  • 최근 생체 신호 측정을 위한 기능성 의류는 동작 잡음에 의한 노이즈를 최대한 줄여 정확한 생체 신호를 측정 가능케 하는 것의 중요성에 대한 논의가 이루어지고 있다. 이에 본 연구는 영향 요인별 고려 사항을 반 영하여 3-리드(lead)방식의 은사 자수의 직물 전극을 개발하고, '일자형 절개 타입', '십자형절개 타입', '엑스형 절개 타입', '곡선 엑스형 절개 타입'의 총 네 가지 타입의 생체신호 센싱 스마트 의류의 시안을 설계하고 제작하였다. 디자인 시안은 민소매형태의 남성용 티셔츠로 신축성 있는 소재를 사용하여 인체 굴곡을 따라 의복과 전극이 밀착될 수 있도록 하였으며, 트랜스미터를 이용하여 메인 컴퓨터로 데이터가 무선 전송되게 하였다. 각 재모듈화형 의류 타입별 인체 동작에 의한 영향과 정지 및 동작 상태에서의 심전도 센싱 성능을 평가하기 위해 동작에 따른 전극의 변위를 측정하고, 심전도 측정 평가를 실시하여 SNR을 분석하였다. 본 실험 결과를 반영하여 의류 디자인 시안의 수정 및 보완 과정을 거친 후, 최종적으로 '연속-부착형', '삽입-분리형'의 두 가지 타입의 생체신호 센싱 스마트의류 디자인 모형의 모듈화 방안을 제시하였다.

  • PDF

직물형 ECG센서 설계를 위한 제직구조 및 내구성에 대한 기초연구 (Basic Study of Weaving Structure and Durability for Fabric-type ECG Sensor Design)

  • 류종우;지영주;김홍제;윤남식
    • 한국염색가공학회지
    • /
    • 제23권3호
    • /
    • pp.219-226
    • /
    • 2011
  • Recently, study of functional clothing for vital sensing is focused on improving conductivity and decreasing resistance, in order to enhance the electrocardiogram(ECG) sensing accuracy and obtained stable environmental durability on operation condition. In this study, four ECG fabrics that having different componnt yarns and weaving structures were produced to analyze their environmental durabilities and electric properties under general operation conditions including different physical and chemical stimulation. For outstanding electric properties and physical properties, the optimized ECG sensing fabric should consist of a fabric of 2 up 3 down twill structure containing 210de silver-coated conductive yarns and polyester yarn in warp and weft directions respectively. The selected fabric has $0.11{\Omega}$ which is relative lower resistance than otherwisely produced fabrics under ECG measurement condition. And it has 7% stable resistance changes under 25% strain and repeated strain.

Application of a Textile-based Inductive Sensor for the Vital Sign Monitoring

  • Gi, Sun Ok;Lee, Young Jae;Koo, Hye Ran;Khang, Seonah;Kim, Kyung-Nam;Kang, Seung-Jin;Lee, Joo Hyeon;Lee, Jeong-Whan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.364-371
    • /
    • 2015
  • In this study, we developed a feasible structure of a textile-based inductive sensor using a machine embroidery method, and applied it to a non-contact type vital sign sensing device based on the principle of magnetic-induced conductivity. The mechanical heart activity signals acquired through the inductive sensor embroidered with conductive textile on fabric were compared with the Lead II ECG signals and with respiration signals, which were simultaneously measured in every case with five subjects. The analysis result showed that the locations of the R-peak in the ECG signal were highly associated with sharp peaks in the signals obtained through the textile-based inductive sensor (r=0.9681). Based on the results, we determined the feasibility of the developed textile-based inductive sensor as a measurement device for the heart rate and respiration characteristics.

Polypyrrole을 증착시킨 Poly(vinyl alcohol) 나노섬유 제조 및 전극용 텍스타일 센서로의 활용 가능성 탐색 -딥 코팅과 현장중합 증착 방식을 중심으로- (Fabrication of Polypyrrole Deposited Poly (vinyl alcohol) Nanofiber Webs by Dip-coating and In situ Polymerization and their Application to Textile Electrode Sensors)

  • 양혁주;김재현;이승신;조길수
    • 한국의류산업학회지
    • /
    • 제22권3호
    • /
    • pp.386-398
    • /
    • 2020
  • This study compared dip-coating and in situ polymerization methods for the development of nanofiber-based E-textile using polypyrrole. Nanofiber webs were fabricated by electrospinning an aqueous poly (vinyl alcohol) (PVA) solution. Subsequently, the PVA nanofiber web underwent thermal treatment to improve water resistance. Dip-coating and in situ polymerization methods were used to deposit polypyrrole on the surfaces of the nanofiber web. An FE-SEM analysis was also conducted to examine specimen surface characteristics along with EDS and FT-IR that analyzed the chemical bonding between polypyrrole and specimens. The line resistance and sheet resistance of the treated specimens were measured. Finally, an electrocardiogram (ECG) was measured with textile sensors made of the polypyrrole-deposited PVA nanofiber webs. The polypyrrole-deposited PVA nanofiber webs fabricated by dip-coating dissolved in the dip-coating solution and indicated damage to the nanofibers. However, in the case of in situ polymerization, polypyrrole nanoparticles were deposited on the surface and inter-web structure of the PVA nanofiber web. The resistance measurements indicated that polypyrrole-deposited PVA nanofiber webs fabricated by in situ polymerization with an average sheet resistance of 5.3 k(Ω/□). Polypyrrole-deposited PVA nanofiber webs fabricated by dip-coating showed an average sheet resistance of 57.3 k(Ω/□). Polypyrrole-deposited PVA nanofibers fabricated by in situ polymerization showed a lower line and sheet resistance; in addition, they detected the electrical activity of the heart during ECG measurements. The electrodes made from polypyrrole-deposited PVA nanofiber webs by in situ polymerization showed the best performance for sensing ECG signals among the evaluated specimens.

동작센싱 스마트레깅스 프로토타입 개발 (Developing a Prototype of Motion-sensing Smart Leggings)

  • 황진희;지승현;김선희
    • 한국의류산업학회지
    • /
    • 제24권6호
    • /
    • pp.694-706
    • /
    • 2022
  • This study focusses on the development of a motion-sensing smart leggings prototype with the help of a module that monitors motion using a fiber-type stretch sensor. Additionally, it acquires data on Electrocardiogram (ECG), respiration, and body temperature signals, for the development of smart clothing used in online exercise coaching and customized healthcare systems. The research process was conducted in the following order: 1) Fabrication of a fiber-type elastic strain sensor for motion monitoring, 2) Positioning and attaching the sensor, 3) Pattern development and three-dimensional (3D) design, 4) Prototyping 5) Wearability test, and 6) Expert evaluation. The 3D design method was used to develop an aesthetic design, and for sensing accurate signal acquisition functions, wearability tests, and expert evaluation. As a result, first, the selection or manufacturing of an appropriate sensor for the function is of utmost importance. Second, the selection and attachment method of a location that can maximize the function of the sensor without interfering with any activity should be studied. Third, the signal line selection and connection method should be considered, and fourth, the aesthetic design should be reflected along with functional verification. In addition, the selection of an appropriate material is important, and tests for washability and durability must be made. This study presented a manufacturing method to improve the functionality and design of smart clothing, through the process of developing a prototype of motion-sensing smart leggings.

직물 전극의 형상 특성이 자계 유도성 전도율 기반의 비접촉식 심장활동 센싱에 미치는 효과의 분석 (An Analysis on the Effect of the Shape Features of the Textile Electrode on the Non-contact Type of Sensing of Cardiac Activity Based on the Magnetic-induced Conductivity Priciple)

  • 지선옥;이영재;구혜란;강선아;박희정;김경섭;이주현;이정환
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.803-810
    • /
    • 2013
  • The purpose of this research is to analyze the effect of shape of the inductive textile electrode on the non-contact heart activity sensing, based on the magnetic-induced conductivity principle. Four types of the inductive textile electrodes were determined according to the combinations of the two shape features. A fiber-metal hybrid-typed conductive thread was developed and applied to materialization of the textile electrodes by embroidery method. The heart activity was extracted through the textile electrode sewn on a T-shirt. The experiments were implemented to constantly measure the heart activity for 20 seconds, in each case of 5 healthy male subjects. The heart activity signals acquired in each type of the inductive textile electrode were analyzed, 1)by drawing a comparison of morphology with those of ECG signal (LeadII), and 2)by calculation of the normalized mean and standard deviation of magnitude of the heart activity signals. The analysis resulted that the relatively better quality of signals were acquired in the 'square' types in the matter of whole shape, while the better results were obtained in 'donut' types in the matter of center hole. Accordingly, the relatively best quality of signals was obtained in the case of 'Square-Donut' type of the inductive textile electrode.

생체신호 모니터링 스마트 의류의 디자인 연구 -심전도 센싱 의류를 중심으로- (A Study on the Design of Smart Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing-)

  • 조하경;조현승;구수민;송하영;강다혜;이주현;이정환;이영재
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 춘계학술대회
    • /
    • pp.123-126
    • /
    • 2009
  • 최근 생체 신호 센싱 기능의 의류가 연구 개발되어 왔으나, 생체 신호 측정 시 착용자의 동작에 의한 치명적인 잡음이 발생하는 문제가 지속적으로 보고되어 왔다. 이에 본 연구는 심전도 센싱 의류를 기반으로 생체 신호 측정의 정확성을 향상시키기 위하여 착용자의 동작에 의한 영향을 최소화할 수 있는 심전도 센싱 스마트 의류의 모형을 개발하고자 하였다. '일자형 절개 타입', '십자형 절개 타입', '엑스형 절개 타입', '곡선 엑스형 절개 타입'의 총 네 가지 타입의 생체신호 센싱 스마트 의류의 시안을 설계하고 제작하였다. 디자인 시안은 민소매 형태의 남성용 티셔츠로 신축성 있는 소재를 사용하여 인체 굴곡을 따라 의복과 전극이 밀착될 수 있도록 하였으며, 트랜스미터를 이용하여 메인 컴퓨터로 데이터가 무선 전송되게 하였다. 본 연구에서는 개발된 4 가지 의류 타임을 기반으로 인체의 정지 및 동작 상태에서의 심전도 센싱 성능을 평가하기 위해 동작에 따른 전극의 변위를 측정하고, 심전도 측정 평가를 실시하여 SNR을 분석하였다. 본 실험 곁과를 반영하여 의류 디자인 시안의 수정 및 보완 과정을 거친 후, 최종적으로 동작 잡음을 최소화하는 생체신호 센싱 스마트 의류 디자인 모형을 제시하였다.

  • PDF

스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향 (Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare)

  • 조현승;구혜란;양진희;이강휘;김상민;이정환;곽휘권;고윤수;오윤중;박서연;김신혜;이주현
    • 감성과학
    • /
    • 제21권4호
    • /
    • pp.63-76
    • /
    • 2018
  • 본 연구의 목적은 스마트 헬스케어를 위해 접촉식 직물전극의 구조가 심장활동 신호 획득에 미치는 영향을 연구하는 것이다. 본 연구에서는 심장활동 신호 측정을 위하여 전극의 크기와 구성방식을 조작한 6종의 접촉식 직물전극을 컴퓨터 자수 방식으로 구현하였고, 이를 가슴밴드에 부착하여 응용형 리드 II(modified Lead II) 방식으로 심장활동 신호를 검출하였다. 건강한 신체의 남성 4명을 대상으로 서서 정지한 자세에서 각 직물전극을 사용하여 심장활동 신호를 검출하였으며, 모든 유형의 전극에 걸쳐 4회씩 반복측정 하였다. 심장활동 신호의 수집을 위해 BIOPAC ECG100 장비를 사용하여 1 kHz로 샘플링하였으며, 검출된 원 신호를 대역통과 필터를 사용하여 필터링하였다. 직물전극의 구조에 따른 심장활동 신호 획득의 성능을 비교하기 위하여 신호의 파형과 크기를 파라미터로 하여 정성적 분석을 실시하였고, 각 전극을 통하여 획득된 심장활동 신호의 SPR(signal power ratio)을 산출함으로써 정량적 분석을 실시하였다. 산출된 SPR 값을 대상으로 하여 비모수 통계분석 방식의 차이검정과 사후검정을 실시함으로써 6개 전극의 구조에 따른 심장활동 신호 획득의 성능 차이를 구체적으로 분석하였다. 연구 결과 접촉식 직물전극의 구조에 따라 심장활동 신호의 품질에는 정성적, 정량적 측면에 걸쳐 모두 주요한 차이가 있는 것이 고찰되었다. 접촉식 직물전극의 구성 측면에 있어서는 입체전극이 평면전극에 비해 더 우수한 품질의 신호가 검출되는 것으로 나타났다. 한편 3가지 전극 크기에 따른 심장활동 신호 획득의 유의한 성능 차이는 발견되지 않았다. 이러한 결과는 심장활동 신호 획득을 위한 접촉식 직물전극 구조의 두 가지 요건 중 구성방식(평면/입체)이 웨어러블 헬스케어를 위한 심장활동 신호 획득의 성능에 주요한 영향을 미치는 것을 시사한다. 본 연구 결과를 기반으로 후속 연구에서는 직물전극이 일체형으로 통합된 의복형 플랫폼을 구현하고 성능 고도화 방안을 연구함으로써, 시공간의 제약 없이 고품질의 심장활동 모니터링이 가능한 스마트 의류 기술을 개발하고자 한다.