• Title/Summary/Keyword: ECG(electrocardiogram)

Search Result 427, Processing Time 0.027 seconds

Changes of Behavioral and Physiological Responses Caused by Color Temperature

  • Lee, Young-Chang;Min, Yoon-Ki;Min, Byung-Chan;Kim, Boseong
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.37-44
    • /
    • 2015
  • LED lighting has an advantage of adjusting color temperature. This change of color temperature may derive change in behavioral and physiological responses of the visual perception for indoor environments. This research examined the changes of behavioral and physiological responses caused by the color temperature. The environment was configured that the indoor temperature was 20 degrees centigrade or less as the perceived uncomfortable environment in winter. Then, the comfortable sensation vote (CSV) and the results of 3-back working memory test were measured as behavioral responses. In addition, the Electrodermal Activity (EDA) and Electrocardiogram (ECG) were measured as the responses of autonomics nervous system (ANS) in the three conditions of color temperature (red: 3862K, white: 5052K, blue: 11,460K). As a result, behavioral responses were not significant by the condition of color temperature, but the tendency of occupants' physiological relaxation appeared in the blue color temperature condition compared with the white color temperature condition. Although the color temperature of LED lighting might be a small factor in terms of the characteristics of indoor environment, it suggests that the color temperature could have an impact on the physiological changes in the parasympathetic nervous system.

The Studies on Treatment of Thoracic Disease Using Lasers and Acupuncture in Dogs (소동물에서 Lasers 및 침술을 이용한 흉부질환 치료에 관한 연구)

  • 김명철;김종만;박종오;김남중;김무강;송치원
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.339-345
    • /
    • 1998
  • This study was performed to investigate the effect of acupuncture in dogs with experimentally induced thoracic disease. Twenty four dogs and 16 cats for the heart study, were divided into four groups(each of 6 in dogs, each of 4 in cats): laserpuncture, electroacupuncture, acupuncture and control group. Heart disease was induced by partial pericardiectomy, and then treatment was done once daily for 4 days. The acupoints used were Xin-shu and Nei-guan. The effect of acupuncture was evaluated by clinical symptom, blood chemical values, electrocardiogram(ECG) and histopathological findings. In dogs, acupuncture group revealed relatively fast recovery and laserpuncture group revealed secondly fast recovery after treatment. In catsl lasewuncture group revealed relatively fast recover and acnpuncture group reveaBed secondly fast recovery after treatment Sixteen dogs for the lung study, were divided into flour groups(each of 4) : laserpuncture, electroacupunchuf, acupuncture and control group. Lung disease was induced by partial lung lobectomy, and then treatment was done once daily for 4 days. The acupoints used were Fei-shu and Shen- zhu. The effect of acupuncture was evaluated by clinical symptoms blood chemical values and histopathological findings. Acupuncture and laserpuncture group revealed relatively fast recovery compared with other groups.

  • PDF

Emotion prediction neural network to understand how emotion is predicted by using heart rate variability measurements

  • Park, Sung Soo;Lee, Kun Chang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.75-82
    • /
    • 2017
  • Correct prediction of emotion is essential for developing advanced health devices. For this purpose, neural network has been successfully used. However, interpretation of how a certain emotion is predicted through the emotion prediction neural network is very tough. When interpreting mechanism about how emotion is predicted by using the emotion prediction neural network can be developed, such mechanism can be effectively embedded into highly advanced health-care devices. In this sense, this study proposes a novel approach to interpreting how the emotion prediction neural network yields emotion. Our proposed mechanism is based on HRV (heart rate variability) measurements, which is based on calculating physiological data out of ECG (electrocardiogram) measurements. Experiment dataset with 23 qualified participants were used to obtain the seven HRV measurement such as Mean RR, SDNN, RMSSD, VLF, LF, HF, LF/HF. Then emotion prediction neural network was modelled by using the HRV dataset. By applying the proposed mechanism, a set of explicit mathematical functions could be derived, which are clearly and explicitly interpretable. The proposed mechanism was compared with conventional neural network to show validity.

Characteristics of Thermal Comfort in Environment Chamber for Winter

  • Kim, Kyung-Hoon;Park, Jong-Il;Song, Yong-Gil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.73-83
    • /
    • 2000
  • The purpose of this study is to analyze and characterize the correlation of the thermal comfort sensation with physiological responses for men in winter indoor environment. A number of experiments were conducted under twenty different environmental conditions with college male students. Clinical information on each participant was reported in terms of electrocardiogram (ECG), electroencephalogram (EEG) and self-centered evaluation. The comfort zone in winter is found, throughout the study, at Standard New Effective Temperature (SET$T^+$) of 25.2$^{\circ}C$, Predicted Mean Vote (PMV) between 0.27 and 0.62, and Thermal Sensation Vote (TSV) in the range of -0.76 and 0.36. The largest difference in skin temperature is measured at the calf area with respect to air temperature changes. Skin sensitivity to environment temperature is explained as calf, head, chest and abdomen in descending order. Change in heat rate is analyzed to be in parallel with that of SET$T^+$.

  • PDF

Implemetation and Estimation of the Wearable PTT Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 착용형 PTT 측정시스템의 구현 및 평가)

  • Kim, Jin-Ho;Kang, Hag-Seong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.137-140
    • /
    • 2010
  • 본 연구에서는 일상생활에서 보다 편리하게 건강모니터링을 수행하기 위해 신체에 착용 가능한 심전도 및 맥파 계측 시스템을 구현하고자 하였다. 이를 위하여 배터리로 구동 가능한 초소형의 심전도 및 맥파 측정 시스템을 구현하였으며, 계측된 생체신호의 무선전송을 위해 초저전력 무선 센서네트워크 기술을 적용한 무선 생체신호 전송시스템을 구현하였다. 무선으로 전송된 심전도 및 맥파 신호는 잡음 제거 및 심박동을 검출하기 위하여 전처리과정과 적응 가변형 문턱치를 적용하였으며, 검출된 심박동으로부터 동맥순환계의 긴장도 및 유순도의 변화를 반영하는 맥파전달시간(pulse transit time, PTT)을 계산하였다. 구현된 무선 맥파전달시간 계측시스템과 기존 상용시스템의 비교 평가를 수행함으로써 구현된 시스템의 유용성을 평가하고자 하였으며, 혈압 및 맥파전달시간의 동시계측을 통해 자세 변화에 따른 혈압의 변화 및 맥파전달시간의 변화양상을 관찰함으로써 혈압과 맥파전달시간의 관계를 추정하고자 하였다.

  • PDF

Effects of Yohimbine on Medetomidine Sedation in Dogs (한국산 잡견에서 Yohimbine이 Medetomidine 진정에 미치는 영향)

  • Park Jong-o;Kim Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.10 no.1
    • /
    • pp.37-46
    • /
    • 1993
  • This study was carried out to evaluate the effects of yohimbine on medetomidine sedation. Twenty dogs were sedated with medetomidine(0.04mg/kg, IM). Twen쇼 minutes after the injection, ten dogs were injected with saline(0.1mg/, IV)for the control group and the others were injected wi yohimbine(0.1mg/kg, IV)for the experimental group. Onset, recovery time, respiratory rate, body temperature, blood chemistry, electrocardiogram(ECG) finding were recorded. The results obtained were summarized as follows; 1. Onset of the sedation was fast and favorable. 2. Recovery time was shorted significantly by yohimbine treatment(p<0.01). 3. Respiratory rates were decreased significantly, but increased to normal level after the yohimblne treatment(p<0.01). 4. Heart rates were decreased significantly; but increased to normal level after the yohimbine treatment(p<0.01). 5. Body temperatures of dogs in the experimental group revealed higher level than those of control group(p<0.01). 6. Arrythmias were observed in both groups but relieved to normal after the yohimbine treatment. 7. Blood chemistry values were not changed significantly by medetomidine and yohimbine treatment. 8. These results showed that yohimbine is an excellent antagonist of medetomidine.

  • PDF

Case reports : Proximal aortic dissection with STEMI-equivalent ECG findings (STEMI equivalent 심전도 소견을 동반한 근위부 대동맥박리 1예)

  • Kim, Ji-Won;Kang, Min Seong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.141-145
    • /
    • 2020
  • The most common symptom of aortic dissection is chest pain, which is similar to acute coronary artery syndrome, making it difficult to diagnose with clinical pattern, requiring various diagnostic methods. About 10-15% of the aortic dissection patients are accompanied by changes in the ST segment by the dissecting flap of the coronary opening, which can lead to delayed diagnosis of aortic dissection, or can adversely affect the patient by administration to unnecessary drugs such as nitroglycerin, thrombolytic agent, and anticoagulants. It is difficult to distinguish aortic dissection from an acute myocardial infarction only through a 12-Lead electrocardiogram at the pre-hospital. The application of cardiac ultrasonography through medical direction to chest pain patients who show ST segmental changes in pre-hospital phase will contribute to the diagnosis of aortic dissection and the improvement of survival rate, such as anticoagulant administration, to patients with acute myocardial infarction.

Wearing of a Whole-Body Compression Garment Can Enhance Exercise Efficiency

  • Jeon, Su-Jeong;Jung, Yu-Jin;Lee, Eun-Jae;Choi, Ji-Hye;Jung, Dongju
    • Biomedical Science Letters
    • /
    • v.27 no.2
    • /
    • pp.88-94
    • /
    • 2021
  • A whole-body compression garment (WBCG) is mainly used for cosmetic purpose in Korea. Another case for wearing the WBCG would be while exercising because it allows the body to move easily. But physiological effects of wearing WBCG to the body have not been known much. To investigate whether wearing WBCG would be helpful for conducting exercises, we measured physiological criteria, which could be influenced by the compression, such as cardiovascular and pulmonary function. Twelve female college students participated in this experiment. Increase of blood pressure was monitored in all of the participants when they wore a WBCG just for 10 minutes. Pulmonary function that requires skeletal muscle contraction was decreased by wearing a WBCG. Blood pressure measured after conducting exercise became even lower when wearing a WBCG than non-wearing. Interestingly, heart pulse remained lower when wearing a WBCG than non-wearing during the whole relaxing period after the exercise. Electrocardiogram (ECG) analyses showed that such lower heart rate largely depended on extension of QT time. For that reason, physiological efficiency index (PEI) was higher for wearing WBCG. These results indicate wearing WBCG could enhance exercise efficiency by lowering heart pulse.

Wearable based Electrocardiogram Sensing Clothes for Monitoring of Vital Signal (생체신호 측정을 위한 웨어러블 기반의 심전도 측정 의복)

  • Yu, Ki-Youp;Han, Ki-Tae;Kim, Ju-Hyun;Kim, Jong-Hun;Chung, Kyung-Yong;Lee, Jung-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.277-278
    • /
    • 2009
  • 차세대 하이테크 스마트 의류는 복합 차원에서의 감성적인 요소를 섬유 패션기술에 IT융합 기술을 이용하여 제공하고 있다. 생체신호를 이용한 감성은 모호하여 정량적이고 객관적인 측정이 어렵고, 그 표현도 제한된 감성 어휘에 의하여 나타나기 때문에 구체적으로 파악하는 것은 어려운 일이다. 이를 위하여 제품의 기능적 측면뿐만 아니라 정서적 감정과 선호도가 반영된 제품의 설계나 디자인 또한 요구되고 있다. 본 논문에서는 생체신호 측정을 위한 웨어러블 기반의 심전도 측정 의복을 제안하였다. 착용자가 평소 자주 입는 티셔츠를 응용하여 답답해하거나 불편하지 않게 제작하고 소매 형태로 신축성있는 소재를 사용한다. 인체의 형태에 따라 의복과 바이오센서의 전극이 안정적으로 밀착될 수 있도록 고탄력 밴드를 이용하여 일자형으로 제작하였다. 심전도 측정 의복을 착용에 의해 수집된 심전도 ECG 파형을 수집하고 심박변화율을 계산하는 시뮬레이션을 개발한다.

Wearable and Implantable Sensors for Cardiovascular Monitoring: A Review

  • Jazba Asad;Jawwad Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.171-185
    • /
    • 2023
  • The cardiovascular syndrome is the dominant reason for death and the number of deaths due to this syndrome has greatly increased recently. Regular cardiac monitoring is crucial in controlling heart parameters, particularly for initial examination and precautions. The quantity of cardiac patients is rising each day and it would increase the load of work for doctors/nurses in handling the patients' situation. Hence, it needed a solution that might benefit doctors/nurses in monitoring the improvement of the health condition of patients in real-time and likewise assure decreasing medical treatment expenses. Regular heart monitoring via wireless body area networks (WBANs) including implantable and wearable medical devices is contemplated as a life-changing technique for medical assistance. This article focuses on the latest development in wearable and implantable devices for cardiovascular monitoring. First, we go through the wearable devices for the electrocardiogram (ECG) monitoring. Then, we reviewed the implantable devices for Blood Pressure (BP) monitoring. Subsequently, the evaluation of leading wearable and implantable sensors for heart monitoring mentioned over the previous six years, the current article provides uncertain direction concerning the description of diagnostic effectiveness, thus intending on making discussion in the technical communal to permit aimed at the formation of well-designed techniques. The article is concluded by debating several technical issues in wearable and implantable technology and their possible potential solutions for conquering these challenges.