• 제목/요약/키워드: ECD

검색결과 498건 처리시간 0.028초

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • 제15권6호
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

심내막상 결손증에 대한 임상고 (Clinical study of endocardial cushion defect: 37 cases report)

  • 조재일;서경필
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.657-665
    • /
    • 1984
  • Thirty-seven patients had undergone repair of a endocardial cushion defect between 1977 and Aug. 1983 in Seoul National University Hospital. Twenty eight had a partial defect, one intermediate defect and eight complete endocardial cushion defect. Tricuspid cleft was found in 4 cases and mitral cleft was in all p-ECD. Seven patients were of type C anatomy in c-ECD. Four patients had associated major anomalies, including three TOF in c-ECD, one coarctation in p- ECD. In p-ECD patients, the septal defect was closed with patch in all cases and the atrioventricular valvular insufficiency was corrected with MVR in 4 cases, TVR in 1 case and simple interrupted sutures in remainders. In c-ECD patients the septal defect was closed with single patch except one case. The atrioventricular valve was repaired with simple interrupted sutures except one MVR and TVR case. The operative mortality was 14.2% in p-ECD, 44.4% in c-ECD, but recent 3 years [1980-1983] mortality was 8.7% in p-ECD, 20% in c-ECD. More than grade III systolic regurgitant murmur was oted postoperatively in 4 cases of c-ECD and 3 cases of p-ECD. The operative risk factors were preoperative NYHA classification, cyanosis, Rp/Rs, systolic pressure of main pulmonary artery and the degree of regurgitation of atrioventricular valves. The causes of death were low cardiac output syndromes, pulmonary complications and arrhythmias.

  • PDF

폴리염화비페닐류 함유 액상폐기물 시험방법별 분석결과 비교 (Comparison of three analytical methods for PCBs-containing liquid wastes)

  • 김교근;윤성규;배우근
    • 분석과학
    • /
    • 제23권3호
    • /
    • pp.278-283
    • /
    • 2010
  • 본 연구에서는 국제적으로 관심의 대상이 되고 있는 폴리염화비페닐류 함유 액상폐기물의 효율적인 관리를 위해 국내에서 사용되고 있는 L2000DX을 이용한 스크리닝, 신속 GC/ECD 및 기존 GC/ECD 분석방법을 절연유 15건에 적용하였다. 분석 결과 L2000DX을 이용한 경우에는 4.4~182.8 mg/L의 농도 범위로 Aroclor 1242 환산농도가 검출된 반면, 기존 GC/ECD 및 신속 GC/ECD를 이용한 분석 결과 각각 불검출~14.63 mg/L 및 불검출~13.03 mg/L로 나타났다. GC/ECD 분석방법들 간에는 약 4 mg/L이하에서 거의 차이가 없었으나, 국내의 규제농도인 2 mg/L부근의 검출농도에서는 일부 시료의 경우 기존 GC/ECD 분석결과(2.71 mg/L)에 비해 신속 GC/ECD 방법이 다소 낮은(2.49 mg/L) 측정치를 보여 국내 규제기준 2 mg/L부근에서 저평가되는 경향이 있는 것으로 나타났다.

청국장식이가 알코올성지방간 쥐의 지질대사 및 간 기능개선에 미치는 영향 (Effects of Chongkukjang Intake on Lipid Metabolism and Liver Function in Alcoholic Fatty Liver Rats)

  • 이은희;천종희
    • 한국식품영양과학회지
    • /
    • 제38권11호
    • /
    • pp.1506-1515
    • /
    • 2009
  • 본 연구는 만성적인 알코올 섭취로 유발된 알코올성지방간 쥐에서 청국장식이가 지질대사 및 간 기능개선에 미치는 영향에 대해 알아보았다. 실험동물은 생후 7주령된 Sprague Dawley계 수컷 흰쥐 35마리에게 30일간 에탄올이 첨가된 액체식이를 공급하여 알코올성지방간을 유발시킨 후 다시 실험동물을 에탄올+카제인식이군(ECD)과 에탄올+청국장식이군(EChD)으로 나누어 각각 총 열량의 36%에 해당하는 에탄올이 함유된 액체 형태의 실험식이를 제공하였다. 실험식이 제공 후 10, 20, 30일째에 각각 혈액과 간을 수집하여 혈액의 지질수준, 간 조직 내 지질과산화물 수준과 그와 관련된 효소의 활성도 및 간 기능 지표 분석에 사용하였다. 실험결과, 식이섭취량은 두 식이군간 유의한 차이를 나타내지 않았고, 일일 평균체중증가량은 각 실험식이를 공급한 20일과 30일에서 EChD군이 ECD군보다 유의하게 높았다. 또한 ECD군은 모든 실험기간 동안 알코올성지방간 상태를 보였으나, EChD군은 10일에서만 지방간 상태를 보였다. 혈청의 총 지질 함량, 중성지방 그리고 총 콜레스테롤은 각 실험식이를 공급한 모든 기간에서 ECD군이 EChD군보다 유의하게 높았고, 혈청 HDL-콜레스테롤은 EChD군이 ECD군보다 유의하게 높게 나타났다. 지질과산화 지표인 간 조직 TBARS 함량은 모든 기간에서 ECD군이 EChD군보다 유의하게 높았고, 간의 conjugated diene 함량은 각 실험식이를 10일간 공급하였을 때만 ECD군이 EChD군보다 유의하게 높게 나타났다. 간 조직 내 항산화효소인 SOD 활성도는 각 실험식이를 30일간 공급하였을 때, 간 catalase와 GPx 활성도는 각 실험식이를 20일과 30일간 공급하였을 때 각각 EChD군이 ECD군보다 유의하게 높았다. 간 기능 지표인 혈청 GOT 활성도는 각 실험식이를 10일과 20일간 공급하였을 때, 혈청 GPT 활성도는 각 실험식이를 10일간 공급하였을 때 각각 ECD군이 EChD군보다 유의하게 높았다. 혈청 LDH 활성도는 각 실험식이를 공급한 모든 기간에서, 혈청 γ-GTP 활성도는 각 실험식이를 20일간 공급하였을 때 각각 ECD군이 EChD군보다 유의하게 높게 나타났다. 혈청 알코올 농도는 각 실험식이를 20일간 공급하였을 때 ECD군이 EChD군보다 유의하게 높았다. ADH 활성도는 각 실험식이를 30일간 공급하였을 때, ALDH 활성도는 각 실험식이를 20일과 30일간 공급하였을 때 각각 EChD군이 ECD군보다 유의하게 높게 나타났다. 본 실험의 결과 청국장의 급여는 간의 중성지방 함량을 감소시켜 알코올로 인한 지방간 생성을 감소시키고, 혈중 총 지질과 중성지방 및 총 콜레스테롤 함량을 감소시키며 항동맥경화 인자인 HDL-콜레스테롤 함량은 증가시켰다. 또한 간의 TBARS 함량과 conjugated diene 함량을 감소시키고, 간 SOD와 catalase 및 GPx 등 항산화 효소의 활성도를 증가시키는 것으로 나타났다. 그리고 혈청 GOT, GPT, LDH 및 γ-GTP 활성도를 감소시켰으며 간 알코올 분해효소인 ADH와 ALDH 활성도는 증가시키는 것으로 나타났다. 따라서 전통발효식품인 청국장은 알코올 섭취로 인해 증가된 혈중 지질 수준과 간의 지질과산화물 수준을 감소시키고, 간 기능 지표 수준을 개선시키며, 항산화 및 알코올 분해효소 활성을 증가시켜 알코올에 의한 산화적 스트레스를 감소시키고 알코올 대사의 중간생성물인 아세트알데히드의 생성을 감소시켜 알코올의 독성으로부터 세포를 보호하여 알코올에 의한 간 손상과 간질환의 발생을 지연시키거나 개선하는데 유용한 것으로 사료된다.

A Variety of Activation Methods Employed in “Activated-Ion” Electron Capture Dissociation Mass Spectrometry: A Test against Bovine Ubiquitin 7+ Ions

  • Oh, Han-Bin;McLafferty, Fred W.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권3호
    • /
    • pp.389-394
    • /
    • 2006
  • Fragmentation efficiencies of various ‘activated-ion’ electron capture dissociation (AI-ECD) methods are compared for a model system of bovine ubiquitin 7+ cations. In AI-ECD studies, sufficient internal energy was given to protein cations prior to ECD application using IR laser radiation, collisions, blackbody radiation, or in-beam collisions, in turn. The added energy was utilized in increasing the population of the precursor ions with less intra-molecular noncovalent bonds or enhancing thermal fluctuations of the protein cations. Removal of noncovalent bonds resulted in extended structures, which are ECD friendly. Under their best conditions, a variety of activation methods showed a similar effectiveness in ECD fragmentation. In terms of the number of fragmented inter-residue bonds, IR laser/blackbody infrared radiation and ‘in-beam’ activation were almost equally efficient with ~70% sequence coverage, while collisions were less productive. In particular, ‘in-beam’ activation showed an excellent effectiveness in characterizing a pre-fractionated single kind of protein species. However, its inherent procedure did not allow for isolation of the protein cations of interest.

심내막상 결손증 치험 5례 (Surgical Treatment of Endocardial Cushion Defects (A Report of 5 Cases))

  • 류지윤
    • Journal of Chest Surgery
    • /
    • 제21권3호
    • /
    • pp.574-582
    • /
    • 1988
  • Endocardial cushion defects is a rare congenital heart disease. We experienced two complete endocardial cushion defects[ECD] and three partial ones, which were successfully repaired between 1986 and 1987. In a patient of complete ECD, associated with secundum ASD, Pulmonary stenosis and Down`s syndrome, the atrial and ventricular septal defects were closed separately with bovine pericardium and Dacron patches respectively, and then pulmonary stenosis was relieved by transannular patch widening in addition to valvotomy and infundibulectomy. In another patient with complete ECD, small interventricular communication was closed with simple suture with pledget and primum ASD was closed with pericardial patch. In first patient of partial ECD, primum atrial septal defect was closed with pericardial patch. In second patient of partial ECD, associated with secundum ASD, direct closure of secundum ASD and patch closure of primum ASD were performed. In third patient of partial ECD, associated with patent foramen ovale[PFO], primum ASD was closed with bovine pericardial patch and PFO was closed directly. In all patient except third patient of partial ECD, mitral clefts were closed with three or four 5-0 prolene interrupted sutures. Transient A-V dissociation developed postoperatively in two patients and transient nodal rhythm developed postoperatively in other two patients. Heart failure in complete ECD with Down`s syndrome was overcome with medical treatment.

  • PDF

와전류 댐퍼의 동적특성 (Dynamic Characteristics of Eddy Current Damper)

  • 곽동기;황재혁;배재성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.947-951
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force thus and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require the damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

  • PDF

플렉시블 전기변색 소자를 위한 고분자 전해질 멤브레인 (Polymer Electrolyte Membranes for Flexible Electrochromic Device)

  • 이지현;강문성
    • 멤브레인
    • /
    • 제30권5호
    • /
    • pp.333-341
    • /
    • 2020
  • 본 연구에서는 플렉시블 전기변색 소자(ECD)에 적용하기 위한 고분자 전해질 멤브레인의 최적 설계 조건을 도출하고자 하였다. 전해질 멤브레인의 제조를 위한 기저 고분자로 접착력 및 투명도가 우수한 polyvinyl butyral (PVB)을 선정하였으며 가소제로는 adipate계 고분자를 사용하였다. 실험결과, ECD 성능에 가장 큰 영향을 미치는 인자는 전해질 멤브레인의 이온 전도도 및 투과도임을 확인할 수 있었다. 또한 상기 인자는 리튬염의 해리 특성과 밀접한 관계를 갖고 있음을 알 수 있었다. 종합적으로 다양한 리튬염 중 음이온의 크기가 큰 LiTFSI 염이 25 wt.% 정도의 함량으로 용해될 때 최적의 ECD 성능을 확인할 수 있었다.

마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리 (Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges)

  • 오승준;문대혁;류진숙;이희경
    • 대한핵의학회지
    • /
    • 제33권4호
    • /
    • pp.430-438
    • /
    • 1999
  • 목적: 마이크로웨이브를 이용한 방사성 동위원소의 표지와 Sep-Pak 카트리지를 이용한 정도관리 방법의 개선으로 신속한 제조가 가능하면서도 높은 표지효율을 가진 방사성 의약품을 얻고자 하였다. 대상 및 방법: $C_{18}$ 그리고 alumina N Sep-Pak카트리지를 이용한 정도관리 방법을 $^{99m}Tc$-ECD, $^{99m}Tc$-MIBI, $^{99m}Tc-MAG_3$에 적용하였고 표지효율을 측정하였다. 마이크로웨이브를 사용하여 상기의 키트에 방사성 동위원소를 표지하여 표지효율을 비교하였다. 결과: 마이크로웨이브에 의해 생성된 세 가지방사성 의약품은 3 ml용액에 $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 10초, $^{99m}Tc-MAG_3$는 15초의 짧은 마이크로웨이브를 조사하여 모두 95% 이상의 표지효율을 나타내었다. $^{99m}Tc$-ECD와 $^{99m}Tc$-MIBI는 Sep-Pak alumina N 카트리지를 사용하여 짧은 시간 내에서도 정확한 정도관리 결과를 얻을 수 있었다. 방사성 의약품의 제조시간은 정도관리를 포함하여 모두 6분 이하를 나타내었다. 결론: Sep-Pak 카트리지를 이용한 정도관리 방법과 마이크로웨이브에 의한 방사성 의약품의 제조 방법은 일상적인 방사성 의약품의 제조에 적용이 가능하였으며, 방사성 의약품의 제조시간을 크게 단축시킬 수 있었다.

  • PDF

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.