• Title/Summary/Keyword: ECD

Search Result 497, Processing Time 0.031 seconds

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

Clinical study of endocardial cushion defect: 37 cases report (심내막상 결손증에 대한 임상고)

  • Jo, Jae-Il;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.657-665
    • /
    • 1984
  • Thirty-seven patients had undergone repair of a endocardial cushion defect between 1977 and Aug. 1983 in Seoul National University Hospital. Twenty eight had a partial defect, one intermediate defect and eight complete endocardial cushion defect. Tricuspid cleft was found in 4 cases and mitral cleft was in all p-ECD. Seven patients were of type C anatomy in c-ECD. Four patients had associated major anomalies, including three TOF in c-ECD, one coarctation in p- ECD. In p-ECD patients, the septal defect was closed with patch in all cases and the atrioventricular valvular insufficiency was corrected with MVR in 4 cases, TVR in 1 case and simple interrupted sutures in remainders. In c-ECD patients the septal defect was closed with single patch except one case. The atrioventricular valve was repaired with simple interrupted sutures except one MVR and TVR case. The operative mortality was 14.2% in p-ECD, 44.4% in c-ECD, but recent 3 years [1980-1983] mortality was 8.7% in p-ECD, 20% in c-ECD. More than grade III systolic regurgitant murmur was oted postoperatively in 4 cases of c-ECD and 3 cases of p-ECD. The operative risk factors were preoperative NYHA classification, cyanosis, Rp/Rs, systolic pressure of main pulmonary artery and the degree of regurgitation of atrioventricular valves. The causes of death were low cardiac output syndromes, pulmonary complications and arrhythmias.

  • PDF

Comparison of three analytical methods for PCBs-containing liquid wastes (폴리염화비페닐류 함유 액상폐기물 시험방법별 분석결과 비교)

  • Kim, Kyeo-Keun;Yoon, Seong-Kyu;Bae, Woo-Keun
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.278-283
    • /
    • 2010
  • This study was performed to compare the analytical results among L2000DX and two GC/ECD methods (rapid and conventional). 15 samples of transformer oils were collected to compare the analytical results. In the analytical results of PCBs-containing transformer oil, the PCBs concentrations were in the range of 4.4 mg/L to 182.8 mg/L with L2000DX, N.D. to 14.63 mg/L with conventional GC/ECD, and N.D. to 13.03 mg/L using rapid GC/ECD. The PCB concentrations detected with the L2000DX showed a large difference to those detected with GC/ECD methods. Otherwise, little difference was shown between the two GC/ECD methods at a concentration range lower than 4 mg/L, although the rapid GC/ECD method tended to detect a slightly lower concentration near the regulation criteria of Korea for 2 mg/L.

Effects of Chongkukjang Intake on Lipid Metabolism and Liver Function in Alcoholic Fatty Liver Rats (청국장식이가 알코올성지방간 쥐의 지질대사 및 간 기능개선에 미치는 영향)

  • Lee, Eun-Hee;Chyun, Jong-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.11
    • /
    • pp.1506-1515
    • /
    • 2009
  • This study was performed to investigate the effect of chongkukjang intake on lipid metabolism and liver function in alcoholic fatty liver rats. Thirty-five 7-weeks old Spargue-Dawley male rats were used as experimental animals. After inducing alcoholic fatty liver, rats were divided into two groups and fed ethanol+casein diet (ECD) or ethanol+chongkukjang diet (EChD). At 10th, 20th and 30th days of the feeding experimental diet, rats were sacrificed to get blood and liver samples for analysis of blood lipids, lipid peroxides, antioxidative enzymes and biochemical indices of liver function. The mean food intake was not significantly different between ECD and EChD groups. Daily weight again of EChD group was significantly higher than that of ECD group at days 20 and 30. Serum total lipid, triglyceride and total cholesterol of ECD group were significantly higher than those of EChD group, while HDL-cholesterol was significantly higher in EChD group. Liver TBARS level of ECD group was significantly higher than that of EChD group. However, liver conjugated diene level was significantly higher in ECD group only at day 10. SOD, CAT and GPx activities of EChD group were significantly higher than those of ECD group at days 20 and 30. In the indices of liver function, GOT and GPT of ECD group were significantly higher than those of EChD group at day 10. LDH was significantly higher in ECD group. γ-GTP was significantly higher in ECD group only at day 20. Serum alcohol concentration of ECD group was significantly higher than that of EChD group at day 30. ADH and ALDH activities of EChD group were significantly higher than those of ECD group at day 30. Therefore, chongkukjang intake seems to give a beneficial effect on improving lipid metabolism and liver function by increasing HDL-cholesterol level, antioxidative enzyme activites, alcohol enzyme activities and decreasing serum lipids, liver TBARS and conjugated diene.

A Variety of Activation Methods Employed in “Activated-Ion” Electron Capture Dissociation Mass Spectrometry: A Test against Bovine Ubiquitin 7+ Ions

  • Oh, Han-Bin;McLafferty, Fred W.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.389-394
    • /
    • 2006
  • Fragmentation efficiencies of various ‘activated-ion’ electron capture dissociation (AI-ECD) methods are compared for a model system of bovine ubiquitin 7+ cations. In AI-ECD studies, sufficient internal energy was given to protein cations prior to ECD application using IR laser radiation, collisions, blackbody radiation, or in-beam collisions, in turn. The added energy was utilized in increasing the population of the precursor ions with less intra-molecular noncovalent bonds or enhancing thermal fluctuations of the protein cations. Removal of noncovalent bonds resulted in extended structures, which are ECD friendly. Under their best conditions, a variety of activation methods showed a similar effectiveness in ECD fragmentation. In terms of the number of fragmented inter-residue bonds, IR laser/blackbody infrared radiation and ‘in-beam’ activation were almost equally efficient with ~70% sequence coverage, while collisions were less productive. In particular, ‘in-beam’ activation showed an excellent effectiveness in characterizing a pre-fractionated single kind of protein species. However, its inherent procedure did not allow for isolation of the protein cations of interest.

Surgical Treatment of Endocardial Cushion Defects (A Report of 5 Cases) (심내막상 결손증 치험 5례)

  • 류지윤
    • Journal of Chest Surgery
    • /
    • v.21 no.3
    • /
    • pp.574-582
    • /
    • 1988
  • Endocardial cushion defects is a rare congenital heart disease. We experienced two complete endocardial cushion defects[ECD] and three partial ones, which were successfully repaired between 1986 and 1987. In a patient of complete ECD, associated with secundum ASD, Pulmonary stenosis and Down`s syndrome, the atrial and ventricular septal defects were closed separately with bovine pericardium and Dacron patches respectively, and then pulmonary stenosis was relieved by transannular patch widening in addition to valvotomy and infundibulectomy. In another patient with complete ECD, small interventricular communication was closed with simple suture with pledget and primum ASD was closed with pericardial patch. In first patient of partial ECD, primum atrial septal defect was closed with pericardial patch. In second patient of partial ECD, associated with secundum ASD, direct closure of secundum ASD and patch closure of primum ASD were performed. In third patient of partial ECD, associated with patent foramen ovale[PFO], primum ASD was closed with bovine pericardial patch and PFO was closed directly. In all patient except third patient of partial ECD, mitral clefts were closed with three or four 5-0 prolene interrupted sutures. Transient A-V dissociation developed postoperatively in two patients and transient nodal rhythm developed postoperatively in other two patients. Heart failure in complete ECD with Down`s syndrome was overcome with medical treatment.

  • PDF

Dynamic Characteristics of Eddy Current Damper (와전류 댐퍼의 동적특성)

  • Kwag, Dong-Gi;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.947-951
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force thus and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require the damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

  • PDF

Polymer Electrolyte Membranes for Flexible Electrochromic Device (플렉시블 전기변색 소자를 위한 고분자 전해질 멤브레인)

  • Lee, Ji-Hyeon;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.30 no.5
    • /
    • pp.333-341
    • /
    • 2020
  • In this study, the optimum design conditions of a polymer electrolyte membrane for application to a flexible electrochromic device (ECD) were tried to be derived. Polyvinyl butyral (PVB) with excellent adhesive property and transparency was selected as the base polymer for the preparation of the electrolyte membrane, and adipate-based polymer was used as the plasticizer. As a result, it was confirmed that the most influential factors on the ECD performance were the ionic conductivity and permeability of the electrolyte membrane. In addition, it was found that the factor has a close relationship with the dissociation property of the lithium salt. Overall, the optimal ECD performance was achieved when LiTFSI salt having a large anion size among various lithium salts was dissolved in a content of about 25 wt.%.

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode (Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템)

  • Yi In-Je;Kang Chi-Jung;Kim Yong-Sang;Kim Ju-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.