• Title/Summary/Keyword: E1 pulse

Search Result 334, Processing Time 0.028 seconds

Effects of Frequency Type on Muscle Function of the Thigh during Electrical Muscle Stimulation (전기근육자극 시 주파수 차이가 대퇴 근육 기능에 미치는 영향)

  • Woen-Sik Chae;Jae-Hu Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the effects of different frequency on of knee extensors muscle function during electrical muscle stimulation (EMS). Method: In this research, 40 subjects who have no musculoskeletal disorder, and less than a year workout experience were recruited in order to analyze effects of EMS with different stimulus frequency. Forty subjects were randomly divided into four groups of ten subjects in each group. A EMS training program with different frequencies (without EMS [WE], EMS with frequency 30 Hz [E30], EMS with frequency 60 Hz [E60], EMS with frequency 90 Hz [E90]) was assigned to each group. Throughout eight weeks of training, test subjects were simultaneously carried out knee extension exercises such as squat, leg extension, and leg-press while using EMS with different frequency (20 min, pulse width 250 ㎲, on-off ratio 1:1). Isokinetic knee extension strength, muscle activity of the rectus femoris (RF), the vastus medialis (VM), and the vastus lateralis (VL), and the median frequency of the RF, the VM, and the VL were collected and compared between pre and post training in order to find effects of applying EMS with different frequencies. For each dependent variable, a one-way ANOVA was to determine whether there were significant differences among four different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: When compared to WE and E90, E30 causes significant increase in isokinetic knee extension strength. No significant differences were found in EMG values across different EMS conditions. However, the median frequency of the VM in E30 was significantly increased than the corresponding value for WE. Conclusion: The results of this study showed that EMS training with 30 Hz frequency had positive effect on knee extensor. Based of the findings of the present study, EMS training with lower frequency may help the performer to focus on developing strength in knee extensor muscles.

The Effects of Excercise Program on Health of the Elderly in Senior Citizen's Center (규칙적인 운동프로그램이 경로당 이용 노인의 건강에 미치는 효과)

  • Choi Sun-Ha
    • Journal of Korean Public Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.38-56
    • /
    • 1997
  • A great deal of attention has been paid to the quality of life in citizens due to the increased number of long term life expectancy. reported as effective in the health promotion of the senior citizens. In this study, the principal investigator developed an exercise program for the senior citizens, which could be educated and managed by nursing staff. This kind approach may support the need of exercise program on regular base via the social organization, which may mean the intentional change of life style. The exercise program consisted of exercise, health education, and a direct the population of the senior A regularexercise has been nursing care. A quasi -experimental study was conducted to investigate the effects of excercise program on health of the elderly in senior citizen's center. Independent variable was a 9 weeks exercise program. Dependent variables were: 1) physical health [e.g. physical fitness(cardiopulmonary endurance, back muscle strength, grip strength, muscular tolerance, flexibility and body fat proportion), physiologic parameters(blood pressure, pulse, respiration. and blood glucose), and perceived physical health status; 2) mental health measured by depression score; and 3) cognitive perception of exercise measured by usefulness and self-efficacy. A total of 37 subjects was randomly assigned into either the control group (without the exercise program: n=18) or the intervention group(with the exercise program: n=19). The results of the study analyzed using a SAS, were as follows: 1) In physical fitness of physical health, there was a significant improvement in cardiopulmonary tolerance. back muscle strength. muscular tolerance and flexibility in the intervention group, compared to the control group, while no difference in grip strength and body fat proportion. The exercise program resulted in decreases in blood pressure, pulse, respiration and blood glucose within normal range and improvement of perceived physical health status in the intervention group. 2) There was a slight increase of mental health(depression score) in the intervention group compared to the control group. but without statistical significance. 3) There was a significant improvement in cognitive perception of exercise(e.g. usefulness and self -efficacy) in the intervention group, compared to the control group. It was concluded that the exercise program employed in this study was appropriate for women senior citizens and had a positive effect on health in general.

  • PDF

Age at Menarche and Brachial-ankle Pulse Wave Velocity in Women with Metabolic Syndrome

  • Jo, Yoon-Kyung;Im, Jee-Aee
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Early age at menarche, which is indicator of early biological maturity, has been shown to be associated with increased adult body mass index. Early menarche has also been associated with many cardiovascular disease risk factors and metabolic syndrome. To evaluate the impact of menarche to cardiovascular risk factor, we assessed by age at menarche, brachial-ankle pulse wave velocity (baPWV), which represents arterial stiffness, in women with or without metabolic syndrome. The subjects recruited for this study were three hundred one women. Relatively early menarche and relatively late menarche were classified according to less than $50^{th}$ percentile for relatively early menarche, and great than the $50^{th}$ percentile for relatively late menarche. Subject were divided four group, 1) women who had not adulthood metabolic syndrome and relatively early menarche, 2) women who had not adulthood metabolic syndrome and relatively late menarche, 3) women who had adulthood metabolic syndrome and relatively early menarche, 4) women who had adulthood metabolic syndrome and relatively late menarche. Women who had a relatively early menarche with adulthood metabolic syndrome had significantly high levels of blood pressure, triglyceride, fasting insulin and homeostatic model assessment of insulin resistance (HOMA-IR) levels than women with late menarche with adulthood metabolic syndrome, and had significantly lower HDL-cholesterol levels. And also, women who underwent a relatively early menarche with metabolic syndrome had highest level of baPWV in adult. In this study we found effect of age at menarche on adulthood metabolic risk factors for cardiovascular disease (e.g., baPWV, insulin resistance, hyperlipidemia) in Korean women.

  • PDF

The Correlation of Serum Osteoprotegerin with Non-Traditional Cardiovascular Risk Factors and Arterial Stiffness in Patients with Pre-Dialysis Chronic Kidney Disease: Results from the KNOW-CKD Study

  • Chae, Seung Yun;Chung, WooKyung;Kim, Yeong Hoon;Oh, Yun Kyu;Lee, Joongyub;Choi, Kyu Hun;Ahn, Curie;Kim, Yong-Soo
    • Journal of Korean Medical Science
    • /
    • v.33 no.53
    • /
    • pp.322.1-322.14
    • /
    • 2018
  • Background: Osteoprotegerin (OPG) plays protective roles against the development of vascular calcification (VC) which greatly contributes to the increased cardiovascular events in patients with chronic kidney disease (CKD). The present study aimed to find the non-traditional, kidney-related cardiovascular risk factors correlated to serum OPG and the effect of serum OPG on the arterial stiffness measured by brachial ankle pulse wave velocity (baPWV) in patients with the pre-dialysis CKD. Methods: We cross-sectionally analyzed the data from the patients in whom baPWV and the serum OPG were measured at the time of enrollment in a prospective pre-dialysis CKD cohort study in Korea. Results: Along with traditional cardiovascular risk factors such as age, diabetes mellitus, pulse pressure, and baPWV, non-traditional, kidney-related factors such as albuminuria, plasma level of hemoglobin, total $CO_2$ content, alkaline phosphatase, and corrected calcium were independent variables for serum OPG in multivariate linear regression. Reciprocally, the serum OPG was positively associated with baPWV in multivariate linear regression. The baPWV in the 3rd and 4th quartile groups of serum OPG were higher than that in the 1st quartile group after adjustments by age, sex and other significant factors for baPWV in linear mixed model. Conclusion: Non-traditional, kidney-related cardiovascular risk factors in addition to traditional cardiovascular risk factors were related to serum level of OPG in CKD. Serum OPG level was significantly related to baPWV. Our study suggests that kidney-related factors involved in CKD-specific pathways for VC play a role in the increased secretion of OPG into circulation in patients with CKD.

Removal of NOx by Pulsed Streamer discharge (펄스 스트리머 방전을 이용한 NOx 제거)

  • 고희석;박재윤;김건호
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

Design and Implementation for DC Motor controller Using Embedded Target (Embedded Target을 이용한 DC Motor제어가 설계 및 구현)

  • Shin, Wee-Jae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.56-62
    • /
    • 2012
  • This paper presents design and implementation of the speed controller for DC motor system using Embeded Target for TI C2000 DSP library in Matlab/Simulink is introduced. Speed controller are easily design and implemented by using the Matlab/Simulink program. Feedback of motor speed is processed through eZdsp F2812 AID converter using encoder and pulse meter as speed sensor. Real-time program of controller is drawn using Simulink and converted program code for speed control of P control, PID control and parameter estimation base adaptive control is downloaded into the TI eZdsp 2812 board. Experiments were carried out to examine validity of speed response for implemented controllers. And even if controlled plant becomes alteration studied controller design and implementation easily method.

Fabrication and Ionic Current Rectification Characteristics of Biomimetic Aluminum Oxide Membrane (생체모방형 비대칭 나노채널을 갖는 산화알루미늄 분리막 제조 및 이온 정류 특성)

  • Jung, Jaehoon;Kim, Jongyoung;Choi, Kiwoon;Lee, Joonho;Kang, Il-suk;Ahn, Chi-won;Cho, Churl-Hee
    • Membrane Journal
    • /
    • v.30 no.3
    • /
    • pp.181-189
    • /
    • 2020
  • In the present study, a biomimetic alumina membrane was fabricated by using selenic acid as an electrolyte to overcome the asymmetry limit of the square pulse anodization process. The prepared membrane has conical channels with a minimum diameter of 10 nm, a maximum diameter of 50 nm, and a length of 5 ㎛. The rectification property was higher than membranes fabricated by sulfuric acid. It showed 2.9 times larger current at +1 V than -1 V. Also, the membrane, which sulfonic acid group was introduced by surface modification, showed 4.2 times larger rectification property at -1 V than +1 V. Theoretical verifications were supported by the numerical analyses of 2D models. The results of the present study present a convenient method to fabricate two type membranes with different rectification properties and are expected to be used to control ion transport.

Electrochemical Properties of Binuclear Tetradentate Schiff Base Cobalt(II), Nickel(II) and Copper(II) Complexes in Nonaqueous Solvents. (V) (비수용매에서 이핵성 네자리 Schiff Base Cobalt(II), Nickel(II) 및 Copper(II) 착물들의 전기화학적 성질 (제 5 보))

  • Chjo Ki-Hyung;Choi Yong-Kook;Lee Song-Ju;Kim Chan-Young;Rim Chae-Pyeong
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.709-719
    • /
    • 1992
  • We synthesized the binuclear tetradentate Schiff base cobalt(II), nickel(II) and copper(II) complexes such as [Co(II)_2(TSBP)(L)_4], [Ni(II)_2(TSBP)(II)_4] and [Cu(II)_2(TSBP)] (TSBP: 3,3',4,4'-tetra(salicylideneimino)-1,1'-biphenyl, L: Py, DMSO and DMF). We identified the binucleated structure of these complexes by elemental analysis, IR-spectrum, UV-visible spectrum, T.G.A. and D.S.C. According to the results for cyclic voltammogram and differential pulse polarogram of 1 mM complexes in nonaqueous solvents included 0.1M TEAP-L (L; Py, DMSO and DMF) as supporting electrolyte, it was found that diffusionally controlled redox processes of four steps through with one electron for binucleated Schiff base Cobalt(II) complex was Co(III)_2 {^\longrightarrow \\_\longleftarrow^e^-}Co(III)Co(II)_2{^\longrightarrow \\_\longleftarrow^e^-}Co(II){^\longrightarrow \\_\longleftarrow^e^-}Co(I){^\longrightarrow \\_\longleftarrow^e^-}Co(I)_2 and two steps with one electron for Nickel(II) and Copper(II) complexes were M(II)_2 {^\longrightarrow \\_\longleftarrow^e^-}M(I)M(I){^\longrightarrow \\_\longleftarrow^e^-}M(I)_2 (M; Ni and Cu) in nonaqueous solvents.

  • PDF

Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction (막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석)

  • Kim, Kyeong-Rae;Kim, Wan-Kyu;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

A CMOS Band-Pass Delta Sigma Modulator and Power Amplifier for Class-S Amplifier Applications (S급 전력 증폭기 응용을 위한 CMOS 대역 통과델타 시그마 변조기 및 전력증폭기)

  • Lee, Yong-Hwan;Kim, Min-Woo;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • A CMOS band-pass delta-sigma modulator(BPDSM) and cascode class-E power amplifier have been developed CMOS for Class-S power amplifier applications. The BPDSM is operating at 1-GHz sampling frequency, which converts a 250-MHz sinusoidal signal to a pulse-width modulated digital signal without the quantization noise. The BPDSM shows a 25-dB SQNR(Signal to Quantization Noise Ratio) and consumes a power of 24 mW at an 1.2-V supply voltage. The class-E power amplifier exhibits an 18.1 dBm of the maximum output power with a 25% drain efficiency at a 3.3-V supply voltage. The BPDSM and class-E PA were fabricated in the Dongbu's 110-nm CMOS process.