• Title/Summary/Keyword: E.coil

Search Result 296, Processing Time 0.036 seconds

Antenna Dependency of Mode Transition in Cylindrical ICP Light-source (원통형 ICP 광원 모드변환의 안테나 의존성)

  • Yang, Jong-Kyung;Pack, Gewnag-Hyeon;Lee, Jong-Chan;Park, Dae-Hee;Yoon, Yang-Woung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.772-778
    • /
    • 2005
  • In this paper, we designed the cylindrical type light source that had a electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the principle of transformer, electrically equivalent circuit of cylindrical type light source was analyzed. According to the parameters of electromagnetic induction which were diameter of coil with $0.3\~1.2\;mm{\Phi}$, number of turns with $4\~12$ turns, distance with $40\~120$ mm and RF power with $10\~150$ W, the electrical and optical properties were measured. When diameter of coil was $0.3\;mm{\Phi}$, number of turns was 8 turns and distance was 40 mm, the highest brightness of 29,730 $cd/m^2$ was shown with RF power 150 W. The relationship between electromagnetic induction and plasma discharges was shown by mode transition from E-mode to H-mode.

Strain Improvement and Genetic Characterization of Tautomycetin Biosynthesis in Streptomyces spp.

  • Choi, Si-Sun;Kim, Myung-Gun;Kim, Eung-Soo
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.420-422
    • /
    • 2005
  • TMC (Tautomycetin) is a liner polyketide immunosuppressive antifungal compound produced by Streptomyces spp. Inhibition of T cell proliferation with TMC was observed highly efficient at 100-fold lower than those needed to achieve maximal inhibition with cyclosporin A. To elucidate the biosynthetic pathway of TMC, a genomic DNA library was constructed using a E. coil-Streptomyces shuttle cosmid vector, pOJ446. The DNA libraries were screened by colony blot hybridization using several polyketide ${\beta}-ketosynthase$ (KS) probes amplified from TMC-producing Streptomyces genomic DNA using polymerase chain reaction (PCR), of which the degenerate primers were designed based on the highly conserved sequences present in KS domains of various type I polyketide synthase genes in Streptomyces species. This library construction and screening approach led to the isolation of several positive cosmid clones representing type I polyketide biosynthetic gene clusters. In addition, a Streptomyces regulatory gene called afsR2 (a global regulatory gene stimulating antibiotic production in both S. coelicolor and S. lividans) was successfully integrated into the TMC-producing Streptomyces chromosome via E. coil-Streptomyces heterologous conjugation mehtod. The more detailed results of production improvement and genetic characterization of TMC-producing Streptomyces spp. will be discussed.

  • PDF

The Development of the Ignition Spark Timing Conversion System for LPG/Gasoline Bi-fuel Vehicle (LPG 및 Gasoline 겸용 차량의 엔진 점화시기 변환 제어시스템 개발)

  • 전봉준;양인권;김재국;김성준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.117-123
    • /
    • 2003
  • In a bi-fuel engine using gasoline and LPG fuel, with the current ignition timing for gasoline being used, the effective performance could not be taken in LPG fuel supply mode. The ignition timing in LPG fuel mode must be advanced much more than that of gasoline mode for the compensation of its lower flame speed, due to engine torque drop. This study aims to develop the control system for ignition spark timing conversion which is composed of hardwares and control algorithm for gasoline/LPG engine. We propose the control system which can advance the ignition spark timing in LPG fuel mode more than used in gasoline fuel mode. The advance of ignition timing is achieved by change of the ignition dwell time of coil igniter. The engine torque and F/E(Fuel-Economy) in LPG fuel mode are measured to evaluate the difference of engine performance between before and alter changing ignition spark timings. The engine torque and F/E are increased respectively, which proves the developed control system is effective so much for gasoline and LPG bi-fuel engine.

Development of Transcutaneous Energy Transmission System for Medical Instrument (의료용 무선 에너지 전달 장치의 개발)

  • 안재목;이동준
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.447-456
    • /
    • 1995
  • As a part of electro-mechanical totally implantable artificial heart (TIAH) program, a transcut- aneous energy transmission system has been developed. By mutual magnetic induction between the first coil on the skin and the subcutaneously implanted second coil, the system transfers elctrical power through the skin. This research aimed at minimizing the size of the implanted part as well as maximizing the transfer efficiency. Using class I amplifier, we achieved above 75% power transfer efficiency at average 40W power transfer level which is required for normal TIAH operation. In vivo performance of the developed system and bio-compatibility of the material used in Implanted parts were evaluated through animal experiments.

  • PDF

Antenna Dependancy of Mode Transition in Cylindrical Inductively Coupled Plasma (ICP) (원통형 Inductively Coupled Plasma (ICP) 광원 모드변환의 안테나 의존성)

  • Choi, Yong-Sung;Cho, Soo-Young;Kim, Young-Keun;Kim, Chang-Bok;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.81-86
    • /
    • 2006
  • In this paper, we designed the cylindrical type light source that had a electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the principle of transformer, electrically equivalent circuit of cylindrical type light source was analyzed. According to the parameters of electromagnetic induction which were diameter of coil with 0.3~1.2 mm, number of turns with 4~12 turns, distance with 40~120 mm and RF power with 10~150 W, the electrical and optical properties were measured. When diameter of coil was 0.3 mm, number of turns was 8 turns and distance was 40 mm, the highest brightness of 29,730 $cd/m^2$ was shown with RF power 150 W. The relationship between electromagnetic induction and plasma discharges was shown by mode transition from E-mode to H-mode.

  • PDF

Fabrication and Fault Test Results of Bi-2212/Cu-Ni Tubes for Superconducting Fault Current Limiting Elements (Bi-2212/Cu-Ni 튜브로 제작한 초전도 한류소자의 단락사고시험 결과)

  • Oh, S.Y.;Yim, S.W.;Yu, S.D.;Kim, H.R.;Hyun, O.B.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.45-49
    • /
    • 2008
  • For the development of superconducting fault current limiters (SFCLs), fault current limiting elements were fabricated out of Bi-2212 bulk tubes and tested. The SFCL elements consisted of tube shaped Bi-2212 bulks and metal shunts for the stabilizers. Firstly, the Bi-2212 bulk tubes were processed based on a design of monofilar coils in order to acquire large resistance and high voltage rating. 300 mm-long Bi-2212 tubes were designed to have the current path of 410 cm in length with 24 turns and 41 mm in diameter. The processed monofilar coil, as designed, had 300 A $I_c$ at 77 K. The fabricated superconducting monofilar coils were affixed to Cu-Ni alloy as that of stabilizers. The Cu-Ni alloys were processed to have the same shape of the superconducting monofilar coils. The Cu-Ni coil had resistivity of 32 ${\mu}{\Omega}$-cm at 77 K and 37 ${\mu}{\Omega}$-cm at 300 K. The metal shunts were attached to the outside of the Bi-2212 monofilar coil by a soldering technique. After the terminals made of copper were attached to both ends of the superconductor-metal shunt composite, the gap between the turns and the surface of the elements was filled with an epoxy and a dense mesh made of FRP in order to enhance the mechanical strength. The completed SFCL elements went through fault tests, and we confirmed that the voltage rating of 143 $V_{rms}$ (E =0.35 $V_{rms}$/cm) could be accomplished.

  • PDF

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation (유도전동기의 구속운전에 따른 전기 및 발열 특성 연구)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.1
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

Effects of Inhibitor Concentrations on the Growth of Recombinant E. chli (재조합된 대장균의 세포성장에 미치는 저해제의 영향)

  • 차월석;나재운이동병
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.132-139
    • /
    • 1996
  • The growth of recombinant E. coil and by-product production were investigated. D-cycloserine was added to increase the secretion of ${\alpha}$-amylase from recombinant E.coil. Even though cell growth was increased for optimal d-cycloserine concentration $0.1g/\ell$, extracellular ${\alpha}$-amylase activity remained almost the same as the case without d-cycloserine. It is important to achieve the high cell density for commercial production of methaboliles including ${\alpha}$-amylase. To achieve this goal, culture conditions should be selected carefully and optimized considering cell growth and by-products production. In cultivating retombinant E. coli, lactic acid and acetic acid turned out to be important by-product which affected cell yield and growth rate.

  • PDF

The Characteristics Analysis and Design for 5kW Contactless Transformer (5kW급 비접촉 변압기 설계 및 특성 분석)

  • Jang, Dong-Uk;Victor, Joao;Kim, Heol-Cheol;Lee, Dong-Su;Jung, Sang-Yong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.703-706
    • /
    • 2011
  • Contactless systems use electromagnetic fields to transport power from railway substation to the traction system. In Korea Railroad Research Institute, KRRI, the RIPS (Railway Inductive Power Supply), has been developed. The RIPS is based on a contactless transformer with a fixed coreless primary and a moving core, compared with E shape and U shape, in the secondary. The primary coil is supply with 20 kHz current which produces a magnetic flux in the secondary core. Further this flux induces a current in the secondary coil.

  • PDF