• Title/Summary/Keyword: E-beam Irradiation

Search Result 188, Processing Time 0.026 seconds

Detection of irradiated food using photostimulated luminescence and thermoluminescence (물리적 방법(PSL, TL)을 이용한 선종별 조사처리 식품의 검지 특성)

  • Jung, Yoo-Kyung;Lee, Ji-Yeon;Kang, Tae-Sun;Jo, Cheon-Ho;Lee, Jae-Hwang;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.399-404
    • /
    • 2016
  • The applicability of photostimulated-luminescence (PSL) and thermoluminescence (TL) for the detection of 12 food materials (potato, onion, garlic, dried pumpkin, black mushroom, black soybean, Cheongkukjang powder, sea mustard, pepper powder, Ramyun soup, corn tea, and green tea powder) irradiated with an electron beam, gamma ray, and X ray at a range of 0.15 to 10 kGy was investigated. For PSL, negative results (less than 700 photon counts (PCs)) were observed from non-irradiated foods while the irradiated foods showed intermediate (879 to 2,414 PCs) and/or positive (19,951 to 65,919,035 PCs) values. In all irradiated samples, the maximum peak of the TL glow curve was observed between 150 and $250^{\circ}C$. Our findings demonstrate the successful application of PSL and TL to determine whether food items were irradiated or not. However, there were no significant differences among the radiation sources.

Reduced Ovarian Cancer Incidence in Women Exposed to Low Dose Ionizing Background Radiation or Radiation to the Ovaries after Treatment for Breast Cancer or Rectosigmoid Cancer

  • Lehrer, Steven;Green, Sheryl;Rosenzweig, Kenneth E
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2979-2982
    • /
    • 2016
  • Background: High dose ionizing radiation can induce ovarian cancer, but the effect of low dose radiation on the development of ovarian cancer has not been extensively studied. We evaluated the effect of low dose radiation and total background radiation, and the radiation delivered to the ovaries during the treatment of rectosigmoid cancer and breast cancer on ovarian cancer incidence. Materials and Methods: Background radiation measurements are from Assessment of Variations in Radiation Exposure in the United States, 2011. Ovarian cancer incidence data are from the Centers for Disease Control and Prevention. Standardized incidence ratios (SIR) of ovarian cancer following breast cancer and rectosigmoid cancer are from Surveillance, Epidemiology, and End Results (SEER) data. Obesity data by US state are from the Centers for Disease Control and Prevention. Mean ages of US state populations are from the United States Census Bureau. Results: We calculated standardized incidence ratios (SIR) from Surveillance, Epidemiology, and End Results (SEER) data, which reveal that in 194,042 cases of breast cancer treated with beam radiation, there were 796 cases of ovarian cancer by 120+ months of treatment (0.41%); in 283, 875 cases of breast cancer not treated with radiation, there were 1,531 cases of ovarian cancer by 120+ months (0.54%). The difference in ovarian cancer incidence in the two groups was significant (p < 0.001, two tailed Fisher exact test). The small dose of scattered ovarian radiation (about 3.09 cGy) from beam radiation to the breast appears to have reduced the risk of ovarian cancer by 24%. In 13,099 cases of rectal or rectosigmoid junction cancer treated with beam radiation in the SEER data, there were 20 cases of ovarian cancer by 120+ months of treatment (0.15%). In 33,305 cases of rectal or rectosigmoid junction cancer not treated with radiation, there were 91 cases of ovarian cancer by 120+ months (0.27%). The difference in ovarian cancer incidence in the two groups was significant (p = 0.017, two tailed Fisher exact test). In other words, the beam radiation to rectum and rectosigmoid that also reached the ovaries reduced the risk of ovarian cancer by 44%. In addition, there was a significant inverse relationship between ovarian cancer in white women and radon background radiation (r = - 0.465. p = 0.002) and total background radiation (r = -0.456, p = 0.002). Because increasing age and obesity are risk factors for ovarian cancer, multivariate linear regression was performed. The inverse relationship between ovarian cancer incidence and radon background was significant (${\beta}=-0.463$, p = 0.002) but unrelated to age (${\beta}=-0.080$, p = 0.570) or obesity (${\beta}=-0.180$, p = 0.208). Conclusions: The reduction of ovarian cancer risk following low dose radiation may be the result of radiation hormesis. Hormesis is a favorable biological response to low toxin exposure. A pollutant or toxin demonstrating hormesis has the opposite effect in small doses as in large doses. In the case of radiation, large doses are carcinogenic. However, lower overall cancer rates are found in U.S. states with high impact radiation. Moreover, there is reduced lung cancer incidence in high radiation background US states where nuclear weapons testing was done. Women at increased risk of ovarian cancer have two choices. They may be closely followed (surveillance) or undergo immediate prophylactic bilateral salpingo-oophorectomy. However, the efficacy of surveillance is questionable. Bilateral salpingo-oophorectomy is considered preferable, although it carries the risk of surgical complications. The data analysis above suggests that low-dose pelvic irradiation might be a good third choice to reduce ovarian cancer risk. Further studies would be worthwhile to establish the lowest optimum radiation dose.

Bending Characteristics Change of Long-Period fiber Grating due to Co-doping of Boron for Optical fiber Sensors (광섬유 센서 구성을 위한 보론 첨가에 따른 장주기 광섬유 격자의 구부림 특성 변화)

  • Moon, Dae-Seung;Chung, Young-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.339-342
    • /
    • 2005
  • In long-period fiber grating (LPFG) to be made up optical fiber sensors, resonance coupling occurs between the forward-propagating core mode and cladding modes at the wavelength that satisfy the Phase matching condition. The resonance wavelength and the coupling strength depends strongly on the external environment like temperature, strain, and ambient index. These characteristics can be utilized for various applications as optical fiber sensors. fabrication of optical fiber gratings is typically based on the photosensitivity effect, i.e. the permanent change of the refractive index upon irradiation of the UV beam, and therefore, fabrication of the optical fiber with high phososensitivity is an important part of the research on optical fiber gratings. In this work, we measured the effort of to-doping of boron on the index difference between the core and cladding of the optical fiber and the sensitivity of the LPFC to the temperature and bending changes. We observed that the index difference between the core and the cladding decreased by $(1.69{\times}10^{-4}/SCCM)$ and the temperature sensitivity of the resonance wavelength shirt decreased by $(0.01145nm/^{\circ}C/SCCM)$. The dependence or the bending-induced changes or the transmission characteristics of LPFG on the tore-cladding index difference was investigated experimentally. The measurement results indicate that the bending sensitivity increases as the index difference decreases.

Characteristics of CuGa precursor deposited by sputter as Electron beam irradiation (Sputtering 방법을 이용하여 증착된 CuGa precursor의 전자빔조사에 따른 특성분석)

  • Park, Insun;Kim, Chaewoong;Jung, Seungchul;Kim, Dongjin;Kwon, Hyuk;Kim, Jinhyeok;Jung, Chae Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.52.1-52.1
    • /
    • 2011
  • 최근에 에너지 자원의 고갈이 다가오는 상황에서 태양전지 분야가 주목받고 있으며 이에 대한 시장이 급격하게 확대되고 있다. 그러나 현재의 태양전지는 주를 이루고있는 실리콘태양전지의 경우 원재료 수급이 불안정하여 가격 변동이 심하다. 따라서 이를 대체할 2세대 태양전지인 박막형 태양전지의 연구가 활발히 이루어지고 있다. 박막형 태양전지 중에서도 주목받고 있는 것은 Cu(In,Ga)$Se_2$(CIGS)박막 태양전지이다. CIGS는 Ga의 농도에 따라 1.02~1.68eV의 다양한 에너지 밴드갭을 갖는 직접천이형 반도체 물질이다. 또한 $1{\times}10^5cm^{-1}$의 높은 광흡수계수를 가지고 있으며, $450{\sim}590^{\circ}C$의 고온공정에서도 매우 안정하여 열화현상이 거의 보이지 않아 박막형 광흡수층 재료로서 적합하다. 흡수층을 제조하는 방법은 여러 가지가 있지만, 본 연구에서는 균일성이 뛰어나고 원료사용효율이 높은 sputtering 방법을 사용하였다. 그리고 결정화하기위해서 유독기체를 사용하는 셀.렌.화. (selenization) 방법 대신 전자빔을 조사하는 방법을 채택하였다. sputtering을 통한 CIGS precursor을 제조하기위해 2~3개의 화합물target을 사용하는데, 대표적인 방법으로 동시에 sputtering하는 co-sputtering 방법과 각각의 단일 층을 쌓아 제조하는 stack형으로 분류된다. 본 연구는 CIGS precursor를 제조하기 앞서 CuGa 단일 층만을 제조하여 공정조건에 따른 박막을 제조하였다. 제조된 CuGa 단일층은 전자빔 처리에 따른 영향을 알아보기 위해 전자빔의 세기와 공정시간을 달리하여 특성을 알아보았다. 실험에서는 Cu:75wt%,Ga:25wt% 조성의 target을 사용하여 공정 압력을 각각 10~1mTorr로 변화시키며 실험을 실시하였으며 공정 power는 50W, 70W, 100W로 변화 시키며 실험을 실시하였다. 이때 실험의 초기진공은 turbo-molecular pump를 이용하여 $1{\times}10^{-6}torr$ 이하로 하였으며, Target과 기판사이의 거리는 모두 같은 조건으로 고정하여 실험을 실시하였다. 박막의 균일성을 증가시키기 위하여 5 rpm의 속도로 기판을 회전하였으며 기판 온도는 가열하지 않고 상온에서 전구체를 증착하였다. 그 후 전자빔의 세기를 고정 시킨 후 전자빔 조사 시간을 조절하여 전자빔 조사 전후의 특성을 각각 분석하였다. 전기적특성은 Hall effect, 4-point probe, 구조적 특성은 SEM,EDS, XRD, XRF 를 이용하여 분석하였다.

  • PDF

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Manufacturing and testing of flat-type divertor mockup with advanced materials

  • Nanyu Mou;Xiyang Zhang;Qianqian Lin;Xianke Yang;Le Han;Lei Cao;Damao Yao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2139-2146
    • /
    • 2023
  • During reactor operation, the divertor must withstand unprecedented simultaneous high heat fluxes and high-energy neutron irradiation. The extremely severe service environment of the divertor imposes a huge challenge to the bonding quality of divertor joints, i.e., the joints must withstand thermal, mechanical and neutron loads, as well as cyclic mode of operation. In this paper, potassium-doped tungsten (KW) is selected as the plasma facing material (PFM), oxygen-free copper (OFC) as the interlayer, oxide dispersion strengthened copper (ODS-Cu) alloy as the heat sink material, and reduced activation ferritic/martensitic (RAFM) steel as the structural material. In this study, a vacuum brazing technology is proposed and optimized to bond Cu and ODS-Cu alloy with the silver-free brazing material CuSnTi. The most appropriate brazing parameters are a brazing temperature of 940 ℃ and a holding time of 15 min. High-quality bonding interfaces have been successfully obtained by vacuum brazing technology, and the average shear strength of the as-obtained KW/Cu and ODS-Cu alloy joints is ~268 MPa. And a fabrication route for manufacturing the flat-type divertor target based on brazing technology is set. For evaluating the reliability of the fabrication technologies under the reactor relevant condition, the high heat flux test at 20 MW/m2 for the as-manufactured flat-type KW/Cu/ODS-Cu/RAFM mockup is carried out by using the Electron-beam Material testing Scenario (EMS-60) with water cooling. This paper reports the improved vacuum brazing technology to connect Cu to ODS-Cu alloy and summarizes the production route, high heat flux (HHF) test, the pre and post non-destructive examination, and the surface results of the flat-type KW/Cu/ODS-Cu/RAFM mockup after the HHF test. The test results demonstrate that the mockup manufactured according to the fabrication route still have structural and interfacial integrity under cyclic high heat loads.

Results of Stereotactic Radiosurgerv with Linear Accelerator for Intracranial Arteriovenous Malformation (두개강내 동정맥기형에서 선형가속기를 이용한 방사선수술의 결과)

  • Lee Kang Kyoo;Park Kyung Ran;Lee Jong Young;Lee Yong Ha
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.215-224
    • /
    • 1997
  • Purpose : Stereotactic radiosurgery with external beam irradiation successfully obliterates carefully selected intracranial arteriovenous malformation (AVM) . We Present clinical and radiological long term results after treatment with a single high dose irradiation using a linear accelerator. Materials and Methods : Rrom January 1991 to June 1994, fifteen patients with intracranial AVM were treated in our hospital with the stereotactic radiosurgery using a linear accelerator. The radiation was delivered using a 6 MV linear accelerator. The prescribed doses at the isocenter varied from 1800 to 2500cGy (median : 2000cGy) and were given as a sin91e fraction. The radiation doses at the periphery of the lesion typically corresponded to the 80-90% isodose line. In 14 patients, complete clinical and/or radiological follow-up examination were available. Results : Angiography was available in 13 patients with a follow-up Period from 18 months to 27 months. Of 13 patients, the overall complete obliteration rate was 92.3% (12 patients). This incidence did not correlate with lesion size. Seizure, headache and progressive neurologic deficit were complete recovered. One Patient experienced hemorrhage at 2 months after treatment. One patient developed radiation induced brain edema in the white matter surrounding nidus at 16 months after treatment and showed complete resolution of the edema in MR image obtained at 27 months after treatment. After a follow-up period of up to 6 years, no radiation induced severe late complications occurred. Conclusion : We conclude that stereotactic radiosurgery using a linear accelerator is an effective and safe therapy for symptomatic and surgically inaccessible intracranial AVMs and the results compare favorably to the more expensive and elaborate systems that are currently available for stereotactic radiosurgery.

  • PDF

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF