• 제목/요약/키워드: E-J power

검색결과 823건 처리시간 0.033초

Optimum Gain Distribution of the Ampilfiers in High Power YLF($Nd^{3+}$)-Phosphate Glass($Nd^{3+}$) Laser System

  • CHi, Kyeong-Koo
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.20-25
    • /
    • 1989
  • The nonlinear, time dependent photon transport equations of Frantz and Nodvik, which describe the amplification of an optical pulse in an active medium, are modified to a simpler equation which describes only the amplification of energy. with this equation, the output energy of the high power YLF(Nd3+)-Phosphate Glass(Nd3+) Laser System is calculated. When the stored energy density Est is 0.10J/㎤, 0.16J/㎤, 0.228J/㎤, and 0.50J/㎤, and with the assumption of uniform population inversion density, the final output energy of this laser system is 5.38J, 176J, 317J, and 283J, respectively. The gain saturation causes distortion of the output beam. This phenomenon is described in detail at the first three rod amplifier systems in the case of E=0.228J/㎤. The peak current and decay time constant of the flashlamps, which are used to obtain population inversion in the active medium, are investigated. The flashlamp driving circuit which has optimum operational performance should have {{{{ SQRT { LC} }} time about 100$\mu$sec.

  • PDF

Certain Clean Decompositions for Matrices over Local Rings

  • Yosum Kurtulmaz;Handan Kose;Huanyin Chen
    • Kyungpook Mathematical Journal
    • /
    • 제63권4호
    • /
    • pp.561-569
    • /
    • 2023
  • An element a ∈ R is strongly rad-clean provided that there exists an idempotent e ∈ R such that a - e ∈ U(R), ae = ea and eae ∈ J(eRe). In this article, we completely determine when a 2 × 2 matrix over a commutative local ring is strongly rad clean. An application to matrices over power-series is also given.

Syngas및 수소를 연료로 사용하는 발전용 가스터빈 성능해석 (Performance Analysis of a Gas Turbine for Power Generation using Syngas as a Fuel)

  • 이종준;차규상;손정락;김동섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3241-3246
    • /
    • 2007
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of the syngas to the performance of a gas turbine in a combined cycle power plant. For this purpose, a commercial gas turbine is selected and its performance characteristics are analyzed with three different fuels, i.e., natural gas ($CH_4$), syngas and hydrogen. It is found that different heating values of those fuels and chemical compositions in their combustion gases are the causes in the different performance characteristics.

  • PDF

500 kV 송전계통의 개폐과전압과 공기절연거리 설계 (Switching Surge Overvoltage and Air Clearance Design of 500 kV Transmission System)

  • 심응보;곽주식;우정욱;한기선;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.644-646
    • /
    • 2005
  • The air clearance of the transmission tower is determined by the switching overvoltage of the system, and the insulator length is determined by contamination design. This paper described the switching overvoltage analysis result of 500 kV system and air clearance design. The overvoltage include fault initiation, fault clearing, closing and reclosing overvoltages. We illustrated the contamination design example, air clearance design of a tower considering swing angle of the conductor.

  • PDF

400 kV 급 장거리 송전선로의 Neutral Reactor 용량과 재폐로 무전압 시간산정 (Determination of neutral reactor and reclosing time for long 400 kV transmission line)

  • 곽주식;강연욱;주형준;권동진;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.664-666
    • /
    • 2005
  • 본 논문에서는 장거리 초고압 송전선로에서의 단상재폐로시에 발생가능한 과전압과 2차아크전류를 EMTP를 이용하여 예측계산 하였다. 예측계산결과로부터 과전압을 억제하고 재폐로 동작이 가능한 최적의 중성점 리액터와 400 kV 급 수평배열 1회선 선로를 단상으로 재폐로 하는데 필요한 재폐로 무전압시간을 구하였다.

  • PDF

345kV 및 154kV 송전철탑의 뇌사고율 예측계산 (The Calculation of Lightning Flashover rate of 345kV/154kV Transmission Tower)

  • 심응보;우정욱;곽주식;민병욱;황정일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2001
  • This paper described the calculation results of lightning flashover rate on the 345kV and 154kV transmission system of KEPCO. The back-flashover rate and shielding failure rate was calculated by FLASH(lightning flashover rate calculation program from IEEE) and KEPRI's own program which is based on the EGM(Electro Geometrical Model) method. The estimated lightning flashover late of 345kV transmission system of double circuit was 1.0 flash per 100km-year, and the lightning flashover rate of 154kV transmission line was 2.0 flash Per 100km-year approximately.

  • PDF

132kV XLPE Cable용 Composite Bushing 기중종단접속함 개발 (Development of 132kV XLPE Cable Composite Bushing EB-A)

  • 김정훈;오응종;김기영;박종기;정영우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.547-549
    • /
    • 2000
  • Silicone insulators have many advantages over porcelain insulators. Especially silicone insulators have good characteristics of impact hardness, surface insulation, ease of processing, mass productivity and don't have risk of bombardment and vandalism. Recently insulation part made by silicone are becoming widely used. In this paper we introduce the development of Sealing End for 132kV XLPE cable with silicone composite hollow insulator and the adoption of it to a actual transmission line in abroad. This paper contains of design procedure, structure, electrical performance of it.

  • PDF

공통 DC단을 갖는 복합발전시스템을 위한 전력균형제어에 관한 연구 (A Study on Power Balance Control for Hybrid Power System with Common DC Link)

  • 정병환;조준석;고재석;최규하;김응상;이창성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.181-185
    • /
    • 2002
  • This paper discusses power balance control of photovoltaic/wind/diesel hybrid generation system for remote area power supplies. There are many control methods for hybrid power system. Among others, it must be adopted that the control method to guarantee a stable balance between supply and demand, regardless of the fluctuation of generator power by atmospheric changes. In this paper, it Is proposed that a hybrid generation system has a power-balanced controller to equilibrate generation power with a load demand, which is composed of DC bus-type power systems. To execute power balance control, it is assumed that all of power generators have a equivalent current-source characteristics. Through the results of simulation, the proposed scheme was verified.

  • PDF

A study on a modeling method about current-voltage characteristic of HTS tape considering resistance of stabilizer

  • Lee, W.S.;Lee, J.;Nam, S.;Ko, T.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.9-12
    • /
    • 2013
  • Current-voltage characteristic models of superconducting material are suggested by many researchers. These current-voltage characteristic models are important because they can be used for design or simulation of superconductor devices. But widely used current-voltage models of superconductor wire still have some limitations. For example, a standard E-J power model has no parameters related with stabilizer's resistance in superconductor wire. In this paper, a current-voltage characteristic modeling method for high temperature superconductor (HTS) tape with considering the effect of stabilizer is introduced. And a current-voltage characteristic of a HTS tape is measured under different stabilizer conditions. Those measured current-voltage characteristics of the HTS tape modeled with proposed modeling method and the modeling results are compared.

분산전원용 동기발전기의 제어기 모델링에 대한 연구 (A Study On the Controller of Synchronous Generator for Distributed Generation)

  • 김창순;김태응;김재언;황진수;류지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2002
  • DG (Distributed Generation) devices such as co-generation systems, fuel cells and photovoltaic power generation systems, etc is introducing into the distribution systems by the deregulation. In this paper, the controller of synchronous generator used for DG is newly designed in order to regulate the real & reactive power and the effect on the islanding phenomenon compared with the traditional controller.

  • PDF